J Tomás Rojas, Jennifer Menzemer, Mustafa S Rashid, Annabel Hayoz, Alexandre Lädermann, Matthias A Zumstein
{"title":"在反向肩关节置换术中,通过头戴式显示器导航的增强现实技术可使计划参数、术中参数和术后参数之间的偏差降低:概念验证案例系列。","authors":"J Tomás Rojas, Jennifer Menzemer, Mustafa S Rashid, Annabel Hayoz, Alexandre Lädermann, Matthias A Zumstein","doi":"10.1016/j.jse.2024.05.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Navigated augmented reality (AR) through a head-mounted display (HMD) has led to accurate glenoid component placement in reverse shoulder arthroplasty (RSA) in an in-vitro setting. The purpose of this study is to evaluate the deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement during RSA, assisted by navigated AR through an HMD, in a surgical setting.</p><p><strong>Methods: </strong>A prospective, multicenter study was conducted. All consecutive patients undergoing RSA in 2 institutions, between August 2021 and January 2023, were considered potentially eligible for inclusion in the study. Inclusion criteria were as follows: age >18 years, surgery assisted by AR through an HMD, and postoperative computed tomography (CT) scans at 6 weeks. All participants agreed to participate in the study and informed consent was provided in all cases. Preoperative CT scans were undertaken for all cases and used for 3-dimensional (3D) planning. Intraoperatively, glenoid preparation and component placement were assisted by a navigated AR system through an HMD in all patients. Intraoperative parameters were recorded by the system. A postoperative CT scan was undertaken at 6 weeks, and 3D reconstruction was performed to obtain postoperative parameters. The deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement was calculated. Outliers were defined as >5° for inclination and retroversion and >5 mm for entry point.</p><p><strong>Results: </strong>Seventeen patients (9 females, 12 right shoulders) with a mean age of 72.8 ± 9.1 years (range, 47.0-82.0) met inclusion criteria. The mean deviation between intra- and postoperative measurements was 1.5° ± 1.0° (range, 0.0°-3.0°) for inclination, 2.8° ± 1.5° (range, 1.0°-4.5°) for retroversion, 1.8 ± 1.0 mm (range, 0.7-3.0 mm) for entry point, and 1.9 ± 1.9 mm (range, 0.0-4.5 mm) for depth. The mean deviation between planned and postoperative values was 2.5° ± 3.2° (range, 0.0°-11.0°) for inclination, 3.4° ± 4.6° (range, 0.0°-18.0°) for retroversion, 2.0 ± 2.5 mm (range, 0.0°-9.7°) for entry point, and 1.3 ± 1.6 mm (range, 1.3-4.5 mm) for depth. There were no outliers between intra- and postoperative values and there were 3 outliers between planned and postoperative values. The mean time (minutes : seconds) for the tracker unit placement and the scapula registration was 03:02 (range, 01:48 to 04:26) and 08:16 (range, 02:09 to 17:58), respectively.</p><p><strong>Conclusion: </strong>The use of a navigated AR system through an HMD in RSA led to low deviations between planned, intraoperative, and postoperative parameters for glenoid component placement.</p>","PeriodicalId":50051,"journal":{"name":"Journal of Shoulder and Elbow Surgery","volume":" ","pages":"567-576"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Navigated augmented reality through a head-mounted display leads to low deviation between planned, intra- and postoperative parameters during glenoid component placement of reverse shoulder arthroplasty: a proof-of-concept case series.\",\"authors\":\"J Tomás Rojas, Jennifer Menzemer, Mustafa S Rashid, Annabel Hayoz, Alexandre Lädermann, Matthias A Zumstein\",\"doi\":\"10.1016/j.jse.2024.05.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Navigated augmented reality (AR) through a head-mounted display (HMD) has led to accurate glenoid component placement in reverse shoulder arthroplasty (RSA) in an in-vitro setting. The purpose of this study is to evaluate the deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement during RSA, assisted by navigated AR through an HMD, in a surgical setting.</p><p><strong>Methods: </strong>A prospective, multicenter study was conducted. All consecutive patients undergoing RSA in 2 institutions, between August 2021 and January 2023, were considered potentially eligible for inclusion in the study. Inclusion criteria were as follows: age >18 years, surgery assisted by AR through an HMD, and postoperative computed tomography (CT) scans at 6 weeks. All participants agreed to participate in the study and informed consent was provided in all cases. Preoperative CT scans were undertaken for all cases and used for 3-dimensional (3D) planning. Intraoperatively, glenoid preparation and component placement were assisted by a navigated AR system through an HMD in all patients. Intraoperative parameters were recorded by the system. A postoperative CT scan was undertaken at 6 weeks, and 3D reconstruction was performed to obtain postoperative parameters. The deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement was calculated. Outliers were defined as >5° for inclination and retroversion and >5 mm for entry point.</p><p><strong>Results: </strong>Seventeen patients (9 females, 12 right shoulders) with a mean age of 72.8 ± 9.1 years (range, 47.0-82.0) met inclusion criteria. The mean deviation between intra- and postoperative measurements was 1.5° ± 1.0° (range, 0.0°-3.0°) for inclination, 2.8° ± 1.5° (range, 1.0°-4.5°) for retroversion, 1.8 ± 1.0 mm (range, 0.7-3.0 mm) for entry point, and 1.9 ± 1.9 mm (range, 0.0-4.5 mm) for depth. The mean deviation between planned and postoperative values was 2.5° ± 3.2° (range, 0.0°-11.0°) for inclination, 3.4° ± 4.6° (range, 0.0°-18.0°) for retroversion, 2.0 ± 2.5 mm (range, 0.0°-9.7°) for entry point, and 1.3 ± 1.6 mm (range, 1.3-4.5 mm) for depth. There were no outliers between intra- and postoperative values and there were 3 outliers between planned and postoperative values. The mean time (minutes : seconds) for the tracker unit placement and the scapula registration was 03:02 (range, 01:48 to 04:26) and 08:16 (range, 02:09 to 17:58), respectively.</p><p><strong>Conclusion: </strong>The use of a navigated AR system through an HMD in RSA led to low deviations between planned, intraoperative, and postoperative parameters for glenoid component placement.</p>\",\"PeriodicalId\":50051,\"journal\":{\"name\":\"Journal of Shoulder and Elbow Surgery\",\"volume\":\" \",\"pages\":\"567-576\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Shoulder and Elbow Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jse.2024.05.006\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Shoulder and Elbow Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jse.2024.05.006","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Navigated augmented reality through a head-mounted display leads to low deviation between planned, intra- and postoperative parameters during glenoid component placement of reverse shoulder arthroplasty: a proof-of-concept case series.
Background: Navigated augmented reality (AR) through a head-mounted display (HMD) has led to accurate glenoid component placement in reverse shoulder arthroplasty (RSA) in an in-vitro setting. The purpose of this study is to evaluate the deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement during RSA, assisted by navigated AR through an HMD, in a surgical setting.
Methods: A prospective, multicenter study was conducted. All consecutive patients undergoing RSA in 2 institutions, between August 2021 and January 2023, were considered potentially eligible for inclusion in the study. Inclusion criteria were as follows: age >18 years, surgery assisted by AR through an HMD, and postoperative computed tomography (CT) scans at 6 weeks. All participants agreed to participate in the study and informed consent was provided in all cases. Preoperative CT scans were undertaken for all cases and used for 3-dimensional (3D) planning. Intraoperatively, glenoid preparation and component placement were assisted by a navigated AR system through an HMD in all patients. Intraoperative parameters were recorded by the system. A postoperative CT scan was undertaken at 6 weeks, and 3D reconstruction was performed to obtain postoperative parameters. The deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement was calculated. Outliers were defined as >5° for inclination and retroversion and >5 mm for entry point.
Results: Seventeen patients (9 females, 12 right shoulders) with a mean age of 72.8 ± 9.1 years (range, 47.0-82.0) met inclusion criteria. The mean deviation between intra- and postoperative measurements was 1.5° ± 1.0° (range, 0.0°-3.0°) for inclination, 2.8° ± 1.5° (range, 1.0°-4.5°) for retroversion, 1.8 ± 1.0 mm (range, 0.7-3.0 mm) for entry point, and 1.9 ± 1.9 mm (range, 0.0-4.5 mm) for depth. The mean deviation between planned and postoperative values was 2.5° ± 3.2° (range, 0.0°-11.0°) for inclination, 3.4° ± 4.6° (range, 0.0°-18.0°) for retroversion, 2.0 ± 2.5 mm (range, 0.0°-9.7°) for entry point, and 1.3 ± 1.6 mm (range, 1.3-4.5 mm) for depth. There were no outliers between intra- and postoperative values and there were 3 outliers between planned and postoperative values. The mean time (minutes : seconds) for the tracker unit placement and the scapula registration was 03:02 (range, 01:48 to 04:26) and 08:16 (range, 02:09 to 17:58), respectively.
Conclusion: The use of a navigated AR system through an HMD in RSA led to low deviations between planned, intraoperative, and postoperative parameters for glenoid component placement.
期刊介绍:
The official publication for eight leading specialty organizations, this authoritative journal is the only publication to focus exclusively on medical, surgical, and physical techniques for treating injury/disease of the upper extremity, including the shoulder girdle, arm, and elbow. Clinically oriented and peer-reviewed, the Journal provides an international forum for the exchange of information on new techniques, instruments, and materials. Journal of Shoulder and Elbow Surgery features vivid photos, professional illustrations, and explicit diagrams that demonstrate surgical approaches and depict implant devices. Topics covered include fractures, dislocations, diseases and injuries of the rotator cuff, imaging techniques, arthritis, arthroscopy, arthroplasty, and rehabilitation.