基于介电特性改变的高灵敏度改良三分裂环超材料传感器,用于血液样本检测

IF 5.3 2区 材料科学 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY APL Materials Pub Date : 2024-07-01 DOI:10.1063/5.0218374
Abdullah Al Mahfazur Rahman, Mohammad Tariqul Islam, Phumin Kirawanich, Badariah Bais, Haitham Alsaif, Abdulwadoud A. Maash, Ahasanul Hoque, Md. Moniruzzaman, Md. Shabiul Islam, Mohamed S. Soliman
{"title":"基于介电特性改变的高灵敏度改良三分裂环超材料传感器,用于血液样本检测","authors":"Abdullah Al Mahfazur Rahman, Mohammad Tariqul Islam, Phumin Kirawanich, Badariah Bais, Haitham Alsaif, Abdulwadoud A. Maash, Ahasanul Hoque, Md. Moniruzzaman, Md. Shabiul Islam, Mohamed S. Soliman","doi":"10.1063/5.0218374","DOIUrl":null,"url":null,"abstract":"This research paper demonstrates a metamaterial (MTM) based sensing technique to detect various blood samples by analyzing their dielectric properties. The performance of this MTM-based sensor is evaluated with the help of mimicked human blood samples that closely resemble the dielectric properties of actual human blood samples. Moreover, the ISM band frequency of 2.4 GHz is chosen as one of the reference resonance frequencies due to its various industrial and medical applications. The resonating patch is developed on the FR-4 substrate with a dimension of 10 × 20 mm2 that provides sharp reference resonances of 2.4 and 4.72 GHz for the spectra of the transmission coefficient with a good quality factor (Q-factor). The MTM sensor can detect the mimicked blood samples with a maximum frequency deviation of up to 650 MHz at 2.4 GHz and up to 850 MHz at 4.72 GHz, with maximum sensitivity of 0.917 and 0.707, respectively. The measured results using the prototype of the sensor support the simulation result with good agreement, indicating high sensing capability. Due to its high sensitivity, figure of merit (FoM), and frequency shifting with dielectric property changes in blood samples, the developed MTM-based sensor can be implemented effectively for quick sensing of infected blood samples and biomedical applications.","PeriodicalId":7985,"journal":{"name":"APL Materials","volume":null,"pages":null},"PeriodicalIF":5.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A highly sensitive modified triple split ring metamaterial-based sensor for blood sample detection based on dielectric property alteration\",\"authors\":\"Abdullah Al Mahfazur Rahman, Mohammad Tariqul Islam, Phumin Kirawanich, Badariah Bais, Haitham Alsaif, Abdulwadoud A. Maash, Ahasanul Hoque, Md. Moniruzzaman, Md. Shabiul Islam, Mohamed S. Soliman\",\"doi\":\"10.1063/5.0218374\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research paper demonstrates a metamaterial (MTM) based sensing technique to detect various blood samples by analyzing their dielectric properties. The performance of this MTM-based sensor is evaluated with the help of mimicked human blood samples that closely resemble the dielectric properties of actual human blood samples. Moreover, the ISM band frequency of 2.4 GHz is chosen as one of the reference resonance frequencies due to its various industrial and medical applications. The resonating patch is developed on the FR-4 substrate with a dimension of 10 × 20 mm2 that provides sharp reference resonances of 2.4 and 4.72 GHz for the spectra of the transmission coefficient with a good quality factor (Q-factor). The MTM sensor can detect the mimicked blood samples with a maximum frequency deviation of up to 650 MHz at 2.4 GHz and up to 850 MHz at 4.72 GHz, with maximum sensitivity of 0.917 and 0.707, respectively. The measured results using the prototype of the sensor support the simulation result with good agreement, indicating high sensing capability. Due to its high sensitivity, figure of merit (FoM), and frequency shifting with dielectric property changes in blood samples, the developed MTM-based sensor can be implemented effectively for quick sensing of infected blood samples and biomedical applications.\",\"PeriodicalId\":7985,\"journal\":{\"name\":\"APL Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APL Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0218374\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APL Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1063/5.0218374","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究论文展示了一种基于超材料 (MTM) 的传感技术,通过分析各种血液样本的介电特性来检测它们。在模拟人体血液样本的帮助下,对这种基于 MTM 的传感器的性能进行了评估,模拟人体血液样本与实际人体血液样本的介电特性非常相似。此外,由于 2.4 GHz 的 ISM 频段具有多种工业和医疗应用,因此被选为参考共振频率之一。谐振贴片是在尺寸为 10 × 20 mm2 的 FR-4 基板上开发的,它能以良好的品质因数(Q 因子)为传输系数频谱提供 2.4 和 4.72 GHz 的尖锐参考谐振。MTM 传感器在 2.4 GHz 和 4.72 GHz 的最大频率偏差分别为 650 MHz 和 850 MHz,最大灵敏度分别为 0.917 和 0.707。传感器原型的测量结果与模拟结果吻合良好,表明传感器具有很强的传感能力。由于具有高灵敏度、优越性(FoM)以及随血液样本介电性质变化而产生的频率偏移,所开发的基于 MTM 的传感器可有效地用于受感染血液样本的快速检测和生物医学应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A highly sensitive modified triple split ring metamaterial-based sensor for blood sample detection based on dielectric property alteration
This research paper demonstrates a metamaterial (MTM) based sensing technique to detect various blood samples by analyzing their dielectric properties. The performance of this MTM-based sensor is evaluated with the help of mimicked human blood samples that closely resemble the dielectric properties of actual human blood samples. Moreover, the ISM band frequency of 2.4 GHz is chosen as one of the reference resonance frequencies due to its various industrial and medical applications. The resonating patch is developed on the FR-4 substrate with a dimension of 10 × 20 mm2 that provides sharp reference resonances of 2.4 and 4.72 GHz for the spectra of the transmission coefficient with a good quality factor (Q-factor). The MTM sensor can detect the mimicked blood samples with a maximum frequency deviation of up to 650 MHz at 2.4 GHz and up to 850 MHz at 4.72 GHz, with maximum sensitivity of 0.917 and 0.707, respectively. The measured results using the prototype of the sensor support the simulation result with good agreement, indicating high sensing capability. Due to its high sensitivity, figure of merit (FoM), and frequency shifting with dielectric property changes in blood samples, the developed MTM-based sensor can be implemented effectively for quick sensing of infected blood samples and biomedical applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
APL Materials
APL Materials NANOSCIENCE & NANOTECHNOLOGYMATERIALS SCIE-MATERIALS SCIENCE, MULTIDISCIPLINARY
CiteScore
9.60
自引率
3.30%
发文量
199
审稿时长
2 months
期刊介绍: APL Materials features original, experimental research on significant topical issues within the field of materials science. In order to highlight research at the forefront of materials science, emphasis is given to the quality and timeliness of the work. The journal considers theory or calculation when the work is particularly timely and relevant to applications. In addition to regular articles, the journal also publishes Special Topics, which report on cutting-edge areas in materials science, such as Perovskite Solar Cells, 2D Materials, and Beyond Lithium Ion Batteries.
期刊最新文献
Energy harvesting and human motion sensing of a 2D piezoelectric hybrid organic–inorganic perovskite A first-principles study on structural stability and magnetoelectric coupling of two-dimensional BaTiO3 ultrathin film with Cr and Cu substituting Ti site Investigation of transverse exchange-springs in electrodeposited nano-heterostructured films through first-order reversal curve analysis Solid phase epitaxy of SrRuO3 encapsulated by SrTiO3 membranes Microgel-based etalon membranes: Characterization and properties
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1