利用 LC-MS/MS 方法探索和检测西他列汀片和原料药中的亚硝胺杂质 Nitroso-STG-19 以及辅料中的亚硝酸盐

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2024-07-03 DOI:10.1039/D4AY00967C
Yajie Hao, Juan Fu, Ruixia Wei, Hao Teng, Guang Yin, Qihui Cao, Zhong Feng and Guimin Zhang
{"title":"利用 LC-MS/MS 方法探索和检测西他列汀片和原料药中的亚硝胺杂质 Nitroso-STG-19 以及辅料中的亚硝酸盐","authors":"Yajie Hao, Juan Fu, Ruixia Wei, Hao Teng, Guang Yin, Qihui Cao, Zhong Feng and Guimin Zhang","doi":"10.1039/D4AY00967C","DOIUrl":null,"url":null,"abstract":"<p >The Food and Drug Administration (FDA) recently reported a new nitrosamine impurity in sitagliptin that was named nitroso-STG-19 (NTTP), whose acceptable intake limit was extremely low at 37 ng per day. In addition, NTTP was found to be a degradation impurity in sitagliptin tablets, which was formed by the reaction of 3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-<em>a</em>]pyrazine hydrochloride and nitrite salts introduced <em>via</em> excipients. Consequently, the NTTP content in tablets was larger than that in active pharmaceutical ingredients (APIs). To control the impurity, an ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) procedure for the detection of NTTP in sitagliptin phosphate tablets and APIs was developed and validated. Furthermore, a derivatization method for the detection of nitrite salts at lower concentration was developed to select applicable excipients to decelerate the generation of NTTP. During validation of the analytical procedure for NTTP, the quantitation limit (LOQ) of NTTP was 56 ppb (0.056 ng mL<small><sup>−1</sup></small>), the linear correlation coefficient was 0.9998, and recoveries of NTTP in spiked samples ranged from 95.5% to 105.2%, indicating that the method is rapid, sensitive and accurate for an NTTP test. In the nitrite salt detection method, the LOQ was 0.21 ng mL<small><sup>−1</sup></small>, and recoveries of NTTP in spiked samples ranged from 87.6% to 107.8%, indicating a sensitive and accurate method, suitable for screening appropriate pharmaceutical excipients.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exploration and detection of nitrosamine impurity nitroso-STG-19 in sitagliptin tablets and API as well as nitrites in excipients by LC-MS/MS methods†\",\"authors\":\"Yajie Hao, Juan Fu, Ruixia Wei, Hao Teng, Guang Yin, Qihui Cao, Zhong Feng and Guimin Zhang\",\"doi\":\"10.1039/D4AY00967C\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >The Food and Drug Administration (FDA) recently reported a new nitrosamine impurity in sitagliptin that was named nitroso-STG-19 (NTTP), whose acceptable intake limit was extremely low at 37 ng per day. In addition, NTTP was found to be a degradation impurity in sitagliptin tablets, which was formed by the reaction of 3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-<em>a</em>]pyrazine hydrochloride and nitrite salts introduced <em>via</em> excipients. Consequently, the NTTP content in tablets was larger than that in active pharmaceutical ingredients (APIs). To control the impurity, an ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) procedure for the detection of NTTP in sitagliptin phosphate tablets and APIs was developed and validated. Furthermore, a derivatization method for the detection of nitrite salts at lower concentration was developed to select applicable excipients to decelerate the generation of NTTP. During validation of the analytical procedure for NTTP, the quantitation limit (LOQ) of NTTP was 56 ppb (0.056 ng mL<small><sup>−1</sup></small>), the linear correlation coefficient was 0.9998, and recoveries of NTTP in spiked samples ranged from 95.5% to 105.2%, indicating that the method is rapid, sensitive and accurate for an NTTP test. In the nitrite salt detection method, the LOQ was 0.21 ng mL<small><sup>−1</sup></small>, and recoveries of NTTP in spiked samples ranged from 87.6% to 107.8%, indicating a sensitive and accurate method, suitable for screening appropriate pharmaceutical excipients.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00967c\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00967c","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

美国食品和药物管理局(FDA)最近报告了西他列汀中一种新的亚硝胺杂质,被命名为亚硝基-STG-19(NTTP),其可接受摄入限量极低,为每天37纳克。此外,研究还发现 NTTP 是西他列汀片剂中的一种降解杂质,由 3-(三氟甲基)-5,6,7,8-四氢-[1,2,4]三唑并[4,3-A]吡嗪盐酸盐和辅料中引入的亚硝酸盐反应生成。因此,片剂中的 NTTP 含量高于原料药。为控制该杂质,开发并验证了一种超高效液相色谱-串联质谱(UPLC-MS/MS)方法,用于检测磷酸西他列汀片剂和活性药物成分(API)中的 NTTP。此外,还开发了一种用于检测低浓度亚硝酸盐的衍生化方法,以选择适用的辅料来减缓 NTTP 的生成。该方法的定量限为56 ppb(0.056 ng/mL),线性相关系数为0.9998,加标回收率为95.5%~105.2%。在亚硝酸盐检测方法中,LOQ为0.21 ng/mL,加标样品中NTTP的回收率为87.6%~107.8%,表明该方法灵敏、准确,适用于筛选合适的药用辅料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exploration and detection of nitrosamine impurity nitroso-STG-19 in sitagliptin tablets and API as well as nitrites in excipients by LC-MS/MS methods†

The Food and Drug Administration (FDA) recently reported a new nitrosamine impurity in sitagliptin that was named nitroso-STG-19 (NTTP), whose acceptable intake limit was extremely low at 37 ng per day. In addition, NTTP was found to be a degradation impurity in sitagliptin tablets, which was formed by the reaction of 3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-a]pyrazine hydrochloride and nitrite salts introduced via excipients. Consequently, the NTTP content in tablets was larger than that in active pharmaceutical ingredients (APIs). To control the impurity, an ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) procedure for the detection of NTTP in sitagliptin phosphate tablets and APIs was developed and validated. Furthermore, a derivatization method for the detection of nitrite salts at lower concentration was developed to select applicable excipients to decelerate the generation of NTTP. During validation of the analytical procedure for NTTP, the quantitation limit (LOQ) of NTTP was 56 ppb (0.056 ng mL−1), the linear correlation coefficient was 0.9998, and recoveries of NTTP in spiked samples ranged from 95.5% to 105.2%, indicating that the method is rapid, sensitive and accurate for an NTTP test. In the nitrite salt detection method, the LOQ was 0.21 ng mL−1, and recoveries of NTTP in spiked samples ranged from 87.6% to 107.8%, indicating a sensitive and accurate method, suitable for screening appropriate pharmaceutical excipients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
A porphyrin-modified CoMoO4 nanosensor array for the detection of crude baijiu. Combined detection of hepatitis B virus surface antigen and hepatitis B virus DNA using a DNA sensor. Correction: Selective fluorescence detection of acetylsalicylic acid, succinic acid and ascorbic acid based on a responsive lanthanide metal fluorescent coordination polymer. Fruit waste-derived carbon dots with rhodamine B for the ratiometric detection of Fe3+ and Cu2. Rational design of monodispersed Au@Pt core-shell nanostructures with excellent peroxidase-mimicking activity for colorimetric detection of Cr(VI).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1