聚乙烯醇-二氧化硅在小型人工血管中的实验应用。

K Tamura, H Mizuno, K Okada, H Katoh, S Hitomi, T Teramatsu, Y Shimizu, T Hino
{"title":"聚乙烯醇-二氧化硅在小型人工血管中的实验应用。","authors":"K Tamura,&nbsp;H Mizuno,&nbsp;K Okada,&nbsp;H Katoh,&nbsp;S Hitomi,&nbsp;T Teramatsu,&nbsp;Y Shimizu,&nbsp;T Hino","doi":"10.3109/10731198509118847","DOIUrl":null,"url":null,"abstract":"<p><p>Polyvinyl alcohol-silica (PVA-SiO2) composite and heparinized PVA-SiO2 were examined in vitro and in vivo as materials to coat artificial vessels to be used for the replacement of small arteries. PVA-SiO2 was observed to prolong coagulation time and on heparinized PVA-SiO2 surfaces no blood coagulation was noticed after a period of two days using the Lee-White and plasma recalcification methods. After placing non-coated and coated surfaces in contact with blood components in vitro and in vivo, the degree of blood component adhesion was greater in non-coated woven Dacron than in PVA-SiO2 coated Dacron. The degree of adhesion was even less in heparinized PVA-SiO2 coated Dacron. Furthermore, artificial vessels made of these 3 types of materials were used to replace parts of the canine abdominal aorta and were removed one and a half years later. Patency rates were as follows: non-coated 2/7, PVA-SiO2-coated 4/7, heparinized PVA-SiO2-coated 8/12. The inner surfaces of these prostheses were observed with light microscopy and scanning electron microscopy. Intima formation was thinner on the PVA-SiO2 composite surfaces than on the control surfaces. Heparin acted as a local anticoagulant and PVA-SiO2 limited intima formation. This report showed that PVA-SiO2 composite coated surfaces can be effective for small artery replacement due to good tissue affinity and anticoagulability.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"13 3-4","pages":"133-52"},"PeriodicalIF":0.0000,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198509118847","citationCount":"3","resultStr":"{\"title\":\"Experimental application of polyvinyl alcohol-silica for small artificial vessels.\",\"authors\":\"K Tamura,&nbsp;H Mizuno,&nbsp;K Okada,&nbsp;H Katoh,&nbsp;S Hitomi,&nbsp;T Teramatsu,&nbsp;Y Shimizu,&nbsp;T Hino\",\"doi\":\"10.3109/10731198509118847\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Polyvinyl alcohol-silica (PVA-SiO2) composite and heparinized PVA-SiO2 were examined in vitro and in vivo as materials to coat artificial vessels to be used for the replacement of small arteries. PVA-SiO2 was observed to prolong coagulation time and on heparinized PVA-SiO2 surfaces no blood coagulation was noticed after a period of two days using the Lee-White and plasma recalcification methods. After placing non-coated and coated surfaces in contact with blood components in vitro and in vivo, the degree of blood component adhesion was greater in non-coated woven Dacron than in PVA-SiO2 coated Dacron. The degree of adhesion was even less in heparinized PVA-SiO2 coated Dacron. Furthermore, artificial vessels made of these 3 types of materials were used to replace parts of the canine abdominal aorta and were removed one and a half years later. Patency rates were as follows: non-coated 2/7, PVA-SiO2-coated 4/7, heparinized PVA-SiO2-coated 8/12. The inner surfaces of these prostheses were observed with light microscopy and scanning electron microscopy. Intima formation was thinner on the PVA-SiO2 composite surfaces than on the control surfaces. Heparin acted as a local anticoagulant and PVA-SiO2 limited intima formation. This report showed that PVA-SiO2 composite coated surfaces can be effective for small artery replacement due to good tissue affinity and anticoagulability.</p>\",\"PeriodicalId\":75597,\"journal\":{\"name\":\"Biomaterials, medical devices, and artificial organs\",\"volume\":\"13 3-4\",\"pages\":\"133-52\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731198509118847\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterials, medical devices, and artificial organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731198509118847\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198509118847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在体外和体内研究了聚乙烯醇-二氧化硅(PVA-SiO2)复合材料和肝素化PVA-SiO2作为小动脉替代人工血管的包被材料。采用Lee-White法和血浆再钙化法,观察到PVA-SiO2可延长凝血时间,在肝素化的PVA-SiO2表面,2天后无凝血现象。在体外和体内实验中,将未涂层和涂层表面与血液成分接触后,未涂层的编织涤纶与血液成分的粘附程度大于PVA-SiO2涂层的编织涤纶。肝素化PVA-SiO2涂层涤纶的粘附程度更低。此外,用这三种材料制成的人工血管代替部分犬腹主动脉,并在一年半后切除。通畅率如下:未包被2/7,pva - sio2包被4/7,肝素化pva - sio2包被8/12。采用光镜和扫描电镜观察假体的内表面。PVA-SiO2复合表面的内膜形成比对照表面薄。肝素作为局部抗凝剂和PVA-SiO2限制内膜形成。该报告表明,PVA-SiO2复合涂层表面具有良好的组织亲和性和抗凝血性,可有效用于小动脉置换术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental application of polyvinyl alcohol-silica for small artificial vessels.

Polyvinyl alcohol-silica (PVA-SiO2) composite and heparinized PVA-SiO2 were examined in vitro and in vivo as materials to coat artificial vessels to be used for the replacement of small arteries. PVA-SiO2 was observed to prolong coagulation time and on heparinized PVA-SiO2 surfaces no blood coagulation was noticed after a period of two days using the Lee-White and plasma recalcification methods. After placing non-coated and coated surfaces in contact with blood components in vitro and in vivo, the degree of blood component adhesion was greater in non-coated woven Dacron than in PVA-SiO2 coated Dacron. The degree of adhesion was even less in heparinized PVA-SiO2 coated Dacron. Furthermore, artificial vessels made of these 3 types of materials were used to replace parts of the canine abdominal aorta and were removed one and a half years later. Patency rates were as follows: non-coated 2/7, PVA-SiO2-coated 4/7, heparinized PVA-SiO2-coated 8/12. The inner surfaces of these prostheses were observed with light microscopy and scanning electron microscopy. Intima formation was thinner on the PVA-SiO2 composite surfaces than on the control surfaces. Heparin acted as a local anticoagulant and PVA-SiO2 limited intima formation. This report showed that PVA-SiO2 composite coated surfaces can be effective for small artery replacement due to good tissue affinity and anticoagulability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo. Particulate aluminum oxide as a bone graft material. Abstracts. Fifth Southern Biomedical Engineering Conference. Shreveport, October 20-21, 1986. Custom-made vaginal balloons for strengthening circumvaginal musculature. Electrical conduction in bone in frequency range 0.4-1.3 GHz.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1