闪烁飞行时间测定仪

IF 0.4 4区 工程技术 Q4 ENGINEERING, MULTIDISCIPLINARY Instruments and Experimental Techniques Pub Date : 2024-06-28 DOI:10.1134/s0020441224700039
V. I. Alekseev, V. A. Baskov, E. A. Varfolomeeva, V. A. Dronov, A. I. L’vov, A. V. Kolzov, Yu. F. Krechetov, V. V. Poliansky, S. S. Sidorin
{"title":"闪烁飞行时间测定仪","authors":"V. I. Alekseev, V. A. Baskov, E. A. Varfolomeeva, V. A. Dronov, A. I. L’vov, A. V. Kolzov, Yu. F. Krechetov, V. V. Poliansky, S. S. Sidorin","doi":"10.1134/s0020441224700039","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Abstract</h3><p>The characteristics of a 50-cm-long module of the scintillation time-of-flight hodoscope have been studied. It has been determined that the coordinate resolution and detection efficiency of the module depend on the voltages applied to the voltage dividers of the photomultiplier tubes and the distance from the hip point of a particle to the photomultiplier tubes. The module has been tested using both a secondary electron beam of the Pakhra accelerator (Lebedev Physical Institute, Russian Academy of Sciences) with an energy of 20 MeV and a <sup>90</sup>Sr+<sup>90</sup>Y radioactive source. The tests show that the minimum values of the coordinate resolution are σ<sub><i>x</i></sub> ≈ 0.1 and 1.3 cm, respectively, and the detection efficiency is ε ≈ 53%.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Scintillation Time-of-Flight Hodoscope\",\"authors\":\"V. I. Alekseev, V. A. Baskov, E. A. Varfolomeeva, V. A. Dronov, A. I. L’vov, A. V. Kolzov, Yu. F. Krechetov, V. V. Poliansky, S. S. Sidorin\",\"doi\":\"10.1134/s0020441224700039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Abstract</h3><p>The characteristics of a 50-cm-long module of the scintillation time-of-flight hodoscope have been studied. It has been determined that the coordinate resolution and detection efficiency of the module depend on the voltages applied to the voltage dividers of the photomultiplier tubes and the distance from the hip point of a particle to the photomultiplier tubes. The module has been tested using both a secondary electron beam of the Pakhra accelerator (Lebedev Physical Institute, Russian Academy of Sciences) with an energy of 20 MeV and a <sup>90</sup>Sr+<sup>90</sup>Y radioactive source. The tests show that the minimum values of the coordinate resolution are σ<sub><i>x</i></sub> ≈ 0.1 and 1.3 cm, respectively, and the detection efficiency is ε ≈ 53%.</p>\",\"PeriodicalId\":587,\"journal\":{\"name\":\"Instruments and Experimental Techniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Instruments and Experimental Techniques\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1134/s0020441224700039\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1134/s0020441224700039","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

摘要 研究了闪烁飞行时间示波器 50 厘米长模块的特性。结果表明,该模块的坐标分辨率和探测效率取决于施加到光电倍增管分压器上的电压以及粒子臀点到光电倍增管之间的距离。该模块使用 Pakhra 加速器(俄罗斯科学院列别杰夫物理研究所)能量为 20 MeV 的次级电子束和 90Sr+90Y 放射源进行了测试。测试表明,坐标分辨率的最小值分别为 σx ≈ 0.1 厘米和 1.3 厘米,探测效率为 ε ≈ 53%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Scintillation Time-of-Flight Hodoscope

Abstract

The characteristics of a 50-cm-long module of the scintillation time-of-flight hodoscope have been studied. It has been determined that the coordinate resolution and detection efficiency of the module depend on the voltages applied to the voltage dividers of the photomultiplier tubes and the distance from the hip point of a particle to the photomultiplier tubes. The module has been tested using both a secondary electron beam of the Pakhra accelerator (Lebedev Physical Institute, Russian Academy of Sciences) with an energy of 20 MeV and a 90Sr+90Y radioactive source. The tests show that the minimum values of the coordinate resolution are σx ≈ 0.1 and 1.3 cm, respectively, and the detection efficiency is ε ≈ 53%.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Instruments and Experimental Techniques
Instruments and Experimental Techniques 工程技术-工程:综合
CiteScore
1.20
自引率
33.30%
发文量
113
审稿时长
4-8 weeks
期刊介绍: Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.
期刊最新文献
Investigation of the Thermal Outgassing from P43 Phosphor and Aerogel for Use in the Vacuum System of the SRF SKIF An Active Vibration Isolator for the Space Optical Clock Application of Glass Capillaries with an Outer Diameter of Less Than One Micrometer in a Manipulator Made Based on an Atomic Force Microscope Comparison of Phase Extraction Methods on the Example of the PN-3 Microwave Interferometer Penning Ion Source in Inertial Electrostatic Confinement Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1