电子能量为 7 兆电子伏的改进型紧凑型贝塔射线管 SEA-7 的图像空间分辨率和轫致辐射有效聚焦尺寸

IF 0.4 4区 工程技术 Q4 ENGINEERING, MULTIDISCIPLINARY Instruments and Experimental Techniques Pub Date : 2024-06-28 DOI:10.1134/S0020441224700246
M. M. Rychkov, V. V. Kaplin, V. A. Smolyanskiy
{"title":"电子能量为 7 兆电子伏的改进型紧凑型贝塔射线管 SEA-7 的图像空间分辨率和轫致辐射有效聚焦尺寸","authors":"M. M. Rychkov,&nbsp;V. V. Kaplin,&nbsp;V. A. Smolyanskiy","doi":"10.1134/S0020441224700246","DOIUrl":null,"url":null,"abstract":"<p>Experimental results of determining the resolution of radiography using the bremsstrahlung from the improved compact SEA-7 betatron with electron energy of 7 MeV are presented. Measurements were made using AGFA NDT D4 PbVacuPac X-ray films and Duplex IQI image quality indicator (model EN 462-5). The obtained results demonstrate a different resolution (approximately 0.16 mm) of thin wire pairs of the indicator in different areas of the radiation cone, i.e., a different horizontal size of the effective radiation focus (approximately 0.2 mm), which must be taken into account when analyzing radiographic images of real objects. The vertical size of the radiation focus (approximately 1.4 mm), which is perpendicular to the plane of the electron orbit, was also estimated.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":"67 1","pages":"94 - 100"},"PeriodicalIF":0.4000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Spatial Resolution of Images and Effective Focus Size of Bremsstrahlung of an Improved Compact Betatron SEA-7 with Electron Energy of 7 MeV\",\"authors\":\"M. M. Rychkov,&nbsp;V. V. Kaplin,&nbsp;V. A. Smolyanskiy\",\"doi\":\"10.1134/S0020441224700246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Experimental results of determining the resolution of radiography using the bremsstrahlung from the improved compact SEA-7 betatron with electron energy of 7 MeV are presented. Measurements were made using AGFA NDT D4 PbVacuPac X-ray films and Duplex IQI image quality indicator (model EN 462-5). The obtained results demonstrate a different resolution (approximately 0.16 mm) of thin wire pairs of the indicator in different areas of the radiation cone, i.e., a different horizontal size of the effective radiation focus (approximately 0.2 mm), which must be taken into account when analyzing radiographic images of real objects. The vertical size of the radiation focus (approximately 1.4 mm), which is perpendicular to the plane of the electron orbit, was also estimated.</p>\",\"PeriodicalId\":587,\"journal\":{\"name\":\"Instruments and Experimental Techniques\",\"volume\":\"67 1\",\"pages\":\"94 - 100\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Instruments and Experimental Techniques\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S0020441224700246\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S0020441224700246","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

摘要 本文介绍了利用电子能量为 7 MeV 的改进型紧凑 SEA-7 电子倍增管产生的轫致辐射确定射线照相分辨率的实验结果。测量使用了 AGFA NDT D4 PbVacuPac X 射线胶片和 Duplex IQI 图像质量指示器(EN 462-5)。所得结果表明,在辐射锥的不同区域,指示器细线对的分辨率不同(约 0.16 毫米),即有效辐射焦点的水平尺寸不同(约 0.2 毫米),在分析真实物体的射线图像时必须考虑到这一点。此外,还估算了垂直于电子轨道平面的辐射焦点垂直尺寸(约 1.4 毫米)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Spatial Resolution of Images and Effective Focus Size of Bremsstrahlung of an Improved Compact Betatron SEA-7 with Electron Energy of 7 MeV

Experimental results of determining the resolution of radiography using the bremsstrahlung from the improved compact SEA-7 betatron with electron energy of 7 MeV are presented. Measurements were made using AGFA NDT D4 PbVacuPac X-ray films and Duplex IQI image quality indicator (model EN 462-5). The obtained results demonstrate a different resolution (approximately 0.16 mm) of thin wire pairs of the indicator in different areas of the radiation cone, i.e., a different horizontal size of the effective radiation focus (approximately 0.2 mm), which must be taken into account when analyzing radiographic images of real objects. The vertical size of the radiation focus (approximately 1.4 mm), which is perpendicular to the plane of the electron orbit, was also estimated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Instruments and Experimental Techniques
Instruments and Experimental Techniques 工程技术-工程:综合
CiteScore
1.20
自引率
33.30%
发文量
113
审稿时长
4-8 weeks
期刊介绍: Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.
期刊最新文献
Measurement of Time Resolution of Scintillation Detectors with EQR-15 Silicon Photodetectors for the Time-of-Flight Neutron Detector of the BM@N Experiment Development of a High Granular TOF Neutron Detector for the BM@N Experiment A Scintillation Amplitude−Coordinate Spectrometer Broadband Receiver for MRI The Improvement of Temperature Sensitivity by Eliminating the Thermal Stress at the Interface of Fiber Bragg Gratings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1