外切酶 III 辅助指数扩增反应 (EXPAR) 用于麻醉后护理期间 miRNA-155 的特异性分析

IF 2.5 4区 化学 Q3 CHEMISTRY, ANALYTICAL Journal of Analytical Science and Technology Pub Date : 2024-06-24 DOI:10.1186/s40543-024-00454-0
Xuejun Wu, Shaolan Zou, Jingshen Dai
{"title":"外切酶 III 辅助指数扩增反应 (EXPAR) 用于麻醉后护理期间 miRNA-155 的特异性分析","authors":"Xuejun Wu, Shaolan Zou, Jingshen Dai","doi":"10.1186/s40543-024-00454-0","DOIUrl":null,"url":null,"abstract":"The persistent obstacle in precise and sensitive identification of microRNAs (miRNAs) pertains to the advancement of expeditious and effective isothermal amplification methodologies suitable for point-of-care environments and monitoring the cancer prognosis in patients receiving post-anesthetic nursing. The exponential amplification reaction (EXPAR) has attracted considerable interest due to its simplicity and ability to rapidly amplify signals. The practical application of the EXPAR is, nevertheless, severely hampered by the inability to differentiate closely related homologous sequences and to modify the designed templates to suit other targets. A loop-stem template for the EXPAR system was developed in this study to facilitate specific target recognition with the aid of exonuclease III (Exo III). This innovation effectively eliminated non-specific hybridization that could occur between the template and interfering sequences, thereby ensuring minimal background amplification of EXPAR. By modulating Exo III-based target recycling, EXPAR based chain amplification and G4/hemin based color reaction, this method facilitated the precise and sensitive examination of miRNA-155, yielding acceptable yields and a minimal detection limit of 0.43 fM. The approach expedites simple and expeditious molecular diagnostic applications involving short nucleic acids and offers an innovative method for enhancing the selectivity of EXPAR-based techniques, providing a robust tool for monitoring the expression level from patients receiving post-anesthetic nursing and guiding the treatment strategy.","PeriodicalId":14967,"journal":{"name":"Journal of Analytical Science and Technology","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exonuclease III assisted exponential amplification reaction (EXPAR) for specific miRNA-155 analysis during post-anesthetic nursing\",\"authors\":\"Xuejun Wu, Shaolan Zou, Jingshen Dai\",\"doi\":\"10.1186/s40543-024-00454-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The persistent obstacle in precise and sensitive identification of microRNAs (miRNAs) pertains to the advancement of expeditious and effective isothermal amplification methodologies suitable for point-of-care environments and monitoring the cancer prognosis in patients receiving post-anesthetic nursing. The exponential amplification reaction (EXPAR) has attracted considerable interest due to its simplicity and ability to rapidly amplify signals. The practical application of the EXPAR is, nevertheless, severely hampered by the inability to differentiate closely related homologous sequences and to modify the designed templates to suit other targets. A loop-stem template for the EXPAR system was developed in this study to facilitate specific target recognition with the aid of exonuclease III (Exo III). This innovation effectively eliminated non-specific hybridization that could occur between the template and interfering sequences, thereby ensuring minimal background amplification of EXPAR. By modulating Exo III-based target recycling, EXPAR based chain amplification and G4/hemin based color reaction, this method facilitated the precise and sensitive examination of miRNA-155, yielding acceptable yields and a minimal detection limit of 0.43 fM. The approach expedites simple and expeditious molecular diagnostic applications involving short nucleic acids and offers an innovative method for enhancing the selectivity of EXPAR-based techniques, providing a robust tool for monitoring the expression level from patients receiving post-anesthetic nursing and guiding the treatment strategy.\",\"PeriodicalId\":14967,\"journal\":{\"name\":\"Journal of Analytical Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Science and Technology\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1186/s40543-024-00454-0\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Science and Technology","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1186/s40543-024-00454-0","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在精确、灵敏地鉴定微RNA(miRNA)方面一直存在的障碍是,如何开发快速、有效的等温扩增方法,以适用于护理点环境和监测接受麻醉后护理的患者的癌症预后。指数扩增反应(EXPAR)因其简便性和快速扩增信号的能力而备受关注。然而,由于无法区分密切相关的同源序列,也无法修改所设计的模板以适应其他目标,EXPAR 的实际应用受到严重阻碍。本研究为 EXPAR 系统开发了一种环茎模板,以便借助外切酶 III(Exo III)进行特异性目标识别。这一创新有效消除了模板与干扰序列之间可能发生的非特异性杂交,从而确保 EXPAR 的背景扩增最小化。通过调节基于 Exo III 的目标回收、基于 EXPAR 的链扩增和基于 G4/hemin 的颜色反应,该方法有助于精确灵敏地检测 miRNA-155,产量可接受,最低检测限为 0.43 fM。该方法加快了涉及短核酸的简单快捷的分子诊断应用,为提高基于 EXPAR 的技术的选择性提供了一种创新方法,为监测接受麻醉后护理的患者的表达水平和指导治疗策略提供了一种强有力的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exonuclease III assisted exponential amplification reaction (EXPAR) for specific miRNA-155 analysis during post-anesthetic nursing
The persistent obstacle in precise and sensitive identification of microRNAs (miRNAs) pertains to the advancement of expeditious and effective isothermal amplification methodologies suitable for point-of-care environments and monitoring the cancer prognosis in patients receiving post-anesthetic nursing. The exponential amplification reaction (EXPAR) has attracted considerable interest due to its simplicity and ability to rapidly amplify signals. The practical application of the EXPAR is, nevertheless, severely hampered by the inability to differentiate closely related homologous sequences and to modify the designed templates to suit other targets. A loop-stem template for the EXPAR system was developed in this study to facilitate specific target recognition with the aid of exonuclease III (Exo III). This innovation effectively eliminated non-specific hybridization that could occur between the template and interfering sequences, thereby ensuring minimal background amplification of EXPAR. By modulating Exo III-based target recycling, EXPAR based chain amplification and G4/hemin based color reaction, this method facilitated the precise and sensitive examination of miRNA-155, yielding acceptable yields and a minimal detection limit of 0.43 fM. The approach expedites simple and expeditious molecular diagnostic applications involving short nucleic acids and offers an innovative method for enhancing the selectivity of EXPAR-based techniques, providing a robust tool for monitoring the expression level from patients receiving post-anesthetic nursing and guiding the treatment strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Science and Technology
Journal of Analytical Science and Technology Environmental Science-General Environmental Science
CiteScore
4.00
自引率
4.20%
发文量
39
审稿时长
13 weeks
期刊介绍: The Journal of Analytical Science and Technology (JAST) is a fully open access peer-reviewed scientific journal published under the brand SpringerOpen. JAST was launched by Korea Basic Science Institute in 2010. JAST publishes original research and review articles on all aspects of analytical principles, techniques, methods, procedures, and equipment. JAST’s vision is to be an internationally influential and widely read analytical science journal. Our mission is to inform and stimulate researchers to make significant professional achievements in science. We aim to provide scientists, researchers, and students worldwide with unlimited access to the latest advances of the analytical sciences.
期刊最新文献
Inorganic iodine and bromine speciation in Arctic snow at picogram-per-grams levels by IC-ICP-MS Accurate determination of high sulfur content in sulfide samples: an optimized ICP-OES method Spray-assisted drop formation liquid-phase microextraction for the determination of sertraline in environmental water samples with matrix-matching calibration in GC–MS Isotopic distribution of bioavailable Sr, Nd, and Pb in Chungcheongbuk-do Province, Korea Exploring the feasibility of a single-protoplast proteomic analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1