含有钙[4]炔-单冠-6 配体的萃取色谱树脂对酸性饲料中放射性铯的吸收显著增强。

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography A Pub Date : 2024-06-26 DOI:10.1016/j.chroma.2024.465091
R.B. Gujar , S.A. Ansari , D.B. Sharma , P.K. Mohapatra
{"title":"含有钙[4]炔-单冠-6 配体的萃取色谱树脂对酸性饲料中放射性铯的吸收显著增强。","authors":"R.B. Gujar ,&nbsp;S.A. Ansari ,&nbsp;D.B. Sharma ,&nbsp;P.K. Mohapatra","doi":"10.1016/j.chroma.2024.465091","DOIUrl":null,"url":null,"abstract":"<div><p>An extraction chromatography resin, prepared by the impregnation of bis-octyloxy-calix[4]arene-mono-crown-6 (BOCMC)onto an acrylic ester based polymeric support material, gave excellent uptake data for the removal of radio-cesium (Cs-137) from nitric acid feed solutions. The weight distribution coefficient (<em>K</em><sub>d</sub>) value of &gt;300 obtained during the present study at 3 M HNO<sub>3</sub> was the highest reported so far while using a calix-crown-6 based extraction chromatographic resin material. Analogous resin reported previously has yielded a <em>K</em><sub>d</sub> value &lt;100 at comparable feed conditions. The sorbed metal ions could be efficiently desorbed with de-ionized water. Kinetic modeling of the uptake data indicated that both the film and the intra-particle diffusion mechanism are simultaneously operating in the sorption of Cs<sup>+</sup>ion onto the BOCMC resin. The metal ion sorption data were fitted to the sorption isotherm models and did not conform to the chemisorptions of physisorption models and indicated a pi-pi interaction between the benzene rings of the calix-crown-6 ligand and the Cs<sup>+</sup> ion. The reusability of the resins was quite satisfactory after 5 cycles and the radiation stability of the resin material was very good upto an absorbed dose of 500 kGy. The results of column studies were quite encouraging with 15 mL (9 bed volumes) as the breakthrough volume while the elution was complete in about 12 bed volumes of de-ionized water.</p></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Remarkable enhancement in radio-cesium uptake from acidic feeds into an extraction chromatography resin containing a calix[4]arene-mono-crown-6 ligand\",\"authors\":\"R.B. Gujar ,&nbsp;S.A. Ansari ,&nbsp;D.B. Sharma ,&nbsp;P.K. Mohapatra\",\"doi\":\"10.1016/j.chroma.2024.465091\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An extraction chromatography resin, prepared by the impregnation of bis-octyloxy-calix[4]arene-mono-crown-6 (BOCMC)onto an acrylic ester based polymeric support material, gave excellent uptake data for the removal of radio-cesium (Cs-137) from nitric acid feed solutions. The weight distribution coefficient (<em>K</em><sub>d</sub>) value of &gt;300 obtained during the present study at 3 M HNO<sub>3</sub> was the highest reported so far while using a calix-crown-6 based extraction chromatographic resin material. Analogous resin reported previously has yielded a <em>K</em><sub>d</sub> value &lt;100 at comparable feed conditions. The sorbed metal ions could be efficiently desorbed with de-ionized water. Kinetic modeling of the uptake data indicated that both the film and the intra-particle diffusion mechanism are simultaneously operating in the sorption of Cs<sup>+</sup>ion onto the BOCMC resin. The metal ion sorption data were fitted to the sorption isotherm models and did not conform to the chemisorptions of physisorption models and indicated a pi-pi interaction between the benzene rings of the calix-crown-6 ligand and the Cs<sup>+</sup> ion. The reusability of the resins was quite satisfactory after 5 cycles and the radiation stability of the resin material was very good upto an absorbed dose of 500 kGy. The results of column studies were quite encouraging with 15 mL (9 bed volumes) as the breakthrough volume while the elution was complete in about 12 bed volumes of de-ionized water.</p></div>\",\"PeriodicalId\":347,\"journal\":{\"name\":\"Journal of Chromatography A\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography A\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0021967324004655\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967324004655","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

通过将双辛氧基钙[4]烯-单冠-6(BOCMC)浸渍到丙烯酸酯基聚合物支撑材料上制备的萃取色谱树脂,在去除硝酸给料溶液中的放射性铯(Cs-137)方面提供了出色的吸收数据。本研究在 3 M HNO3 条件下获得的重量分布系数 (Kd) 值大于 300,是迄今为止使用钙冠-6 型萃取色谱树脂材料获得的最高值。之前报道的类似树脂对 BOCMC 树脂的 Kd 值为 +离子。金属离子吸附数据与吸附等温线模型相拟合,与物理吸附模型的化学吸附不符,表明钙冠-6 配体的苯环与 Cs+ 离子之间存在 pi-pi 相互作用。经过 5 次循环后,树脂的可重复使用性相当令人满意,在吸收剂量达到 500 kGy 时,树脂材料的辐射稳定性非常好。色谱柱研究结果令人鼓舞,突破体积为 15 mL(9 个床层体积),而洗脱则在约 12 个床层体积的去离子水中完成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Remarkable enhancement in radio-cesium uptake from acidic feeds into an extraction chromatography resin containing a calix[4]arene-mono-crown-6 ligand

An extraction chromatography resin, prepared by the impregnation of bis-octyloxy-calix[4]arene-mono-crown-6 (BOCMC)onto an acrylic ester based polymeric support material, gave excellent uptake data for the removal of radio-cesium (Cs-137) from nitric acid feed solutions. The weight distribution coefficient (Kd) value of >300 obtained during the present study at 3 M HNO3 was the highest reported so far while using a calix-crown-6 based extraction chromatographic resin material. Analogous resin reported previously has yielded a Kd value <100 at comparable feed conditions. The sorbed metal ions could be efficiently desorbed with de-ionized water. Kinetic modeling of the uptake data indicated that both the film and the intra-particle diffusion mechanism are simultaneously operating in the sorption of Cs+ion onto the BOCMC resin. The metal ion sorption data were fitted to the sorption isotherm models and did not conform to the chemisorptions of physisorption models and indicated a pi-pi interaction between the benzene rings of the calix-crown-6 ligand and the Cs+ ion. The reusability of the resins was quite satisfactory after 5 cycles and the radiation stability of the resin material was very good upto an absorbed dose of 500 kGy. The results of column studies were quite encouraging with 15 mL (9 bed volumes) as the breakthrough volume while the elution was complete in about 12 bed volumes of de-ionized water.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chromatography A
Journal of Chromatography A 化学-分析化学
CiteScore
7.90
自引率
14.60%
发文量
742
审稿时长
45 days
期刊介绍: The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.
期刊最新文献
Fabrication of sea urchin shaped polyaniline-modified magnetic microporous organic network for efficient extraction of non-steroidal anti-inflammatory drugs from animal-derived food samples. Research trends in functionalized Fe3O4 composites based on affinity recognition systems for targeted extraction of natural products. Bivalent affinity binding-inspired PPARγ immobilization with selective conformation and improved ligand-binding activity. Addressing a major interference in the quantification of psilocin in mouse plasma: Development of a validated liquid chromatography tandem mass spectrometry method. Engineering of dual recognition functional aptamer-molecularly imprinted polymeric solid-phase microextraction for detecting of 17β-estradiol in meat samples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1