Andre Karius, Lisa Marie Leifeld, Vratislav Strnad, Claudia Schweizer, Rainer Fietkau, Christoph Bert
{"title":"使用首个独立的近距离放射治疗红外摄像-CT 组合系统进行最初的针跟踪--分析跟踪的准确性和不确定性。","authors":"Andre Karius, Lisa Marie Leifeld, Vratislav Strnad, Claudia Schweizer, Rainer Fietkau, Christoph Bert","doi":"10.1007/s00066-024-02253-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A prototype infrared camera - cone-beam computed tomography (CBCT) system for tracking in brachytherapy has recently been developed. We evaluated for the first time the corresponding tracking accuracy and uncertainties, and implemented a tracking-based prediction of needles on CBCT scans.</p><p><strong>Methods: </strong>A marker tool rigidly attached to needles was 3D printed. The precision and accuracy of tool tracking was then evaluated for both static and dynamic scenarios. Euclidean distances between the tracked and CBCT-derived markers were assessed as well. To implement needle tracking, ground truth models of the tool attached to 200 mm and 160 mm needles were matched to the tracked positions in order to project the needles into CBCT scans. Deviations between projected and actual needle tips were measured. Finally, we put our results into perspective with simulations of the system's tracking uncertainties.</p><p><strong>Results: </strong>For the stationary scenario and dynamic movements, we achieved tool-tracking precision and accuracy of 0.04 ± 0.06 mm and 0.16 ± 0.18 mm, respectively. The tracked marker positions differed by 0.52 ± 0.18 mm from the positions determined via CBCT. In addition, the predicted needle tips in air deviated from the actual tip positions by only 1.62 ± 0.68 mm (200 mm needle) and 1.49 ± 0.62 mm (160 mm needle). The simulated tracking uncertainties resulted in tip variations of 1.58 ± 0.91 mm and 1.31 ± 0.69 mm for the 200 mm and 160 mm needles, respectively.</p><p><strong>Conclusion: </strong>With the innovative system it was possible to achieve a high tracking and prediction accuracy of marker tool and needles. The system shows high potential for applicator tracking in brachytherapy.</p>","PeriodicalId":21998,"journal":{"name":"Strahlentherapie und Onkologie","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Initial needle tracking with the first standalone combined infrared camera - CT system for brachytherapy-analysis of tracking accuracy and uncertainties.\",\"authors\":\"Andre Karius, Lisa Marie Leifeld, Vratislav Strnad, Claudia Schweizer, Rainer Fietkau, Christoph Bert\",\"doi\":\"10.1007/s00066-024-02253-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>A prototype infrared camera - cone-beam computed tomography (CBCT) system for tracking in brachytherapy has recently been developed. We evaluated for the first time the corresponding tracking accuracy and uncertainties, and implemented a tracking-based prediction of needles on CBCT scans.</p><p><strong>Methods: </strong>A marker tool rigidly attached to needles was 3D printed. The precision and accuracy of tool tracking was then evaluated for both static and dynamic scenarios. Euclidean distances between the tracked and CBCT-derived markers were assessed as well. To implement needle tracking, ground truth models of the tool attached to 200 mm and 160 mm needles were matched to the tracked positions in order to project the needles into CBCT scans. Deviations between projected and actual needle tips were measured. Finally, we put our results into perspective with simulations of the system's tracking uncertainties.</p><p><strong>Results: </strong>For the stationary scenario and dynamic movements, we achieved tool-tracking precision and accuracy of 0.04 ± 0.06 mm and 0.16 ± 0.18 mm, respectively. The tracked marker positions differed by 0.52 ± 0.18 mm from the positions determined via CBCT. In addition, the predicted needle tips in air deviated from the actual tip positions by only 1.62 ± 0.68 mm (200 mm needle) and 1.49 ± 0.62 mm (160 mm needle). The simulated tracking uncertainties resulted in tip variations of 1.58 ± 0.91 mm and 1.31 ± 0.69 mm for the 200 mm and 160 mm needles, respectively.</p><p><strong>Conclusion: </strong>With the innovative system it was possible to achieve a high tracking and prediction accuracy of marker tool and needles. The system shows high potential for applicator tracking in brachytherapy.</p>\",\"PeriodicalId\":21998,\"journal\":{\"name\":\"Strahlentherapie und Onkologie\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strahlentherapie und Onkologie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00066-024-02253-3\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strahlentherapie und Onkologie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00066-024-02253-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
Initial needle tracking with the first standalone combined infrared camera - CT system for brachytherapy-analysis of tracking accuracy and uncertainties.
Purpose: A prototype infrared camera - cone-beam computed tomography (CBCT) system for tracking in brachytherapy has recently been developed. We evaluated for the first time the corresponding tracking accuracy and uncertainties, and implemented a tracking-based prediction of needles on CBCT scans.
Methods: A marker tool rigidly attached to needles was 3D printed. The precision and accuracy of tool tracking was then evaluated for both static and dynamic scenarios. Euclidean distances between the tracked and CBCT-derived markers were assessed as well. To implement needle tracking, ground truth models of the tool attached to 200 mm and 160 mm needles were matched to the tracked positions in order to project the needles into CBCT scans. Deviations between projected and actual needle tips were measured. Finally, we put our results into perspective with simulations of the system's tracking uncertainties.
Results: For the stationary scenario and dynamic movements, we achieved tool-tracking precision and accuracy of 0.04 ± 0.06 mm and 0.16 ± 0.18 mm, respectively. The tracked marker positions differed by 0.52 ± 0.18 mm from the positions determined via CBCT. In addition, the predicted needle tips in air deviated from the actual tip positions by only 1.62 ± 0.68 mm (200 mm needle) and 1.49 ± 0.62 mm (160 mm needle). The simulated tracking uncertainties resulted in tip variations of 1.58 ± 0.91 mm and 1.31 ± 0.69 mm for the 200 mm and 160 mm needles, respectively.
Conclusion: With the innovative system it was possible to achieve a high tracking and prediction accuracy of marker tool and needles. The system shows high potential for applicator tracking in brachytherapy.
期刊介绍:
Strahlentherapie und Onkologie, published monthly, is a scientific journal that covers all aspects of oncology with focus on radiooncology, radiation biology and radiation physics. The articles are not only of interest to radiooncologists but to all physicians interested in oncology, to radiation biologists and radiation physicists. The journal publishes original articles, review articles and case studies that are peer-reviewed. It includes scientific short communications as well as a literature review with annotated articles that inform the reader on new developments in the various disciplines concerned and hence allow for a sound overview on the latest results in radiooncology research.
Founded in 1912, Strahlentherapie und Onkologie is the oldest oncological journal in the world. Today, contributions are published in English and German. All articles have English summaries and legends. The journal is the official publication of several scientific radiooncological societies and publishes the relevant communications of these societies.