{"title":"使用超声波去除硬件。","authors":"","doi":"10.1016/j.recot.2024.07.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Osteosynthesis hardware removal is one of the most frequent practices in Orthopaedic electives surgeries and is usually carried out guided under fluoroscopy. There are other tools such as ultrasound that allow us to visualise the hardware with the advantage of being free of ionising radiation and with better availability. The objective of our study is to analyse the results obtained in patients undergoing hardware removal in the operating room under ultrasound assistance and local anaesthesia.</p></div><div><h3>Material and methods</h3><p>A descriptive study was carried out collecting variables such as demographic data, reason for the removal, pain during the procedure and in subsequent days, as well as the duration and rate of success of the procedure and the degree of satisfaction.</p></div><div><h3>Results</h3><p>We obtained a 100% success in ultrasound-guided extraction without the need for conventional radiology, with a mean VAS of 1.91 and need for subsequent analgesia in 36.4% of the cases, with syndesmotic dynamisation being the most frequent reason for intervention.</p></div><div><h3>Conclusion</h3><p>Ultrasound is a useful tool in osteosynthesis hardware removal, and that may be sufficient by itself; also saving health personnel and patients from ionising radiation resulting from the use of conventional fluoroscopy.</p></div>","PeriodicalId":39664,"journal":{"name":"Revista Espanola de Cirugia Ortopedica y Traumatologia","volume":"68 5","pages":"Pages T482-T489"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S188844152400122X/pdfft?md5=a5553bd5758097e955ae9d6d01523336&pid=1-s2.0-S188844152400122X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"[Translated article] Use of ultrasound for hardware removal\",\"authors\":\"\",\"doi\":\"10.1016/j.recot.2024.07.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Osteosynthesis hardware removal is one of the most frequent practices in Orthopaedic electives surgeries and is usually carried out guided under fluoroscopy. There are other tools such as ultrasound that allow us to visualise the hardware with the advantage of being free of ionising radiation and with better availability. The objective of our study is to analyse the results obtained in patients undergoing hardware removal in the operating room under ultrasound assistance and local anaesthesia.</p></div><div><h3>Material and methods</h3><p>A descriptive study was carried out collecting variables such as demographic data, reason for the removal, pain during the procedure and in subsequent days, as well as the duration and rate of success of the procedure and the degree of satisfaction.</p></div><div><h3>Results</h3><p>We obtained a 100% success in ultrasound-guided extraction without the need for conventional radiology, with a mean VAS of 1.91 and need for subsequent analgesia in 36.4% of the cases, with syndesmotic dynamisation being the most frequent reason for intervention.</p></div><div><h3>Conclusion</h3><p>Ultrasound is a useful tool in osteosynthesis hardware removal, and that may be sufficient by itself; also saving health personnel and patients from ionising radiation resulting from the use of conventional fluoroscopy.</p></div>\",\"PeriodicalId\":39664,\"journal\":{\"name\":\"Revista Espanola de Cirugia Ortopedica y Traumatologia\",\"volume\":\"68 5\",\"pages\":\"Pages T482-T489\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S188844152400122X/pdfft?md5=a5553bd5758097e955ae9d6d01523336&pid=1-s2.0-S188844152400122X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Espanola de Cirugia Ortopedica y Traumatologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S188844152400122X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Espanola de Cirugia Ortopedica y Traumatologia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S188844152400122X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
导言:骨合成硬件拆除是骨科择期手术中最常见的做法之一,通常在透视引导下进行。还有其他一些工具,如超声波,可以让我们直观地看到硬件,其优点是没有电离辐射,而且可用性更好。我们的研究旨在分析在超声波辅助和局部麻醉下,在手术室内进行硬件切除的患者所获得的结果。材料和方法 我们进行了一项描述性研究,收集了人口统计学数据、移除原因、手术过程中和随后几天的疼痛、手术持续时间和成功率以及满意度等变量。结果 我们在超声引导下拔牙的成功率为 100%,无需进行传统放射学检查,平均 VAS 值为 1.91,36.4% 的病例需要进行后续镇痛,最常见的干预原因是联合肌动力不足。结论 超声波是一种有用的骨合成硬件移除工具,其本身可能就足够了;同时还能使医务人员和患者免于因使用传统透视而产生的电离辐射。
[Translated article] Use of ultrasound for hardware removal
Introduction
Osteosynthesis hardware removal is one of the most frequent practices in Orthopaedic electives surgeries and is usually carried out guided under fluoroscopy. There are other tools such as ultrasound that allow us to visualise the hardware with the advantage of being free of ionising radiation and with better availability. The objective of our study is to analyse the results obtained in patients undergoing hardware removal in the operating room under ultrasound assistance and local anaesthesia.
Material and methods
A descriptive study was carried out collecting variables such as demographic data, reason for the removal, pain during the procedure and in subsequent days, as well as the duration and rate of success of the procedure and the degree of satisfaction.
Results
We obtained a 100% success in ultrasound-guided extraction without the need for conventional radiology, with a mean VAS of 1.91 and need for subsequent analgesia in 36.4% of the cases, with syndesmotic dynamisation being the most frequent reason for intervention.
Conclusion
Ultrasound is a useful tool in osteosynthesis hardware removal, and that may be sufficient by itself; also saving health personnel and patients from ionising radiation resulting from the use of conventional fluoroscopy.