Jiesuck Park, Jaeik Jeon, Yeonyee E Yoon, Yeonggul Jang, Jiyeon Kim, Dawun Jeong, Jina Lee, Youngtaek Hong, Seongmin Ha, Arsanjani Reza, Hyung-Bok Park, Seung-Ah Lee, Hyejung Choi, Hong-Mi Choi, In-Chang Hwang, Goo-Yeong Cho, Hyuk-Jae Chang
{"title":"人工智能增强的左心室舒张功能自动化评估:一项关于可行性、诊断验证和结果预测的试点研究。","authors":"Jiesuck Park, Jaeik Jeon, Yeonyee E Yoon, Yeonggul Jang, Jiyeon Kim, Dawun Jeong, Jina Lee, Youngtaek Hong, Seongmin Ha, Arsanjani Reza, Hyung-Bok Park, Seung-Ah Lee, Hyejung Choi, Hong-Mi Choi, In-Chang Hwang, Goo-Yeong Cho, Hyuk-Jae Chang","doi":"10.21037/cdt-24-25","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Evaluating left ventricular diastolic function (LVDF) is crucial in echocardiography; however, the complexity and time demands of current guidelines challenge clinical use. This study aimed to develop an artificial intelligence (AI)-based framework for automatic LVDF assessment to reduce subjectivity and improve accuracy and outcome prediction.</p><p><strong>Methods: </strong>We developed an AI-based LVDF assessment framework using a nationwide echocardiographic dataset from five tertiary hospitals. This framework automatically identifies views, calculates diastolic parameters, including mitral inflow and annular velocities (E/A ratio, e' velocity, and E/e' ratio), maximal tricuspid regurgitation velocity, left atrial (LA) volume index, and left atrial reservoir strain (LARS). Subsequently, it grades LVDF according to guidelines. The AI-framework was validated on an external dataset composed of randomly screened 173 outpatients who underwent transthoracic echocardiography with suspicion for diastolic dysfunction and 33 individuals from medical check-ups with normal echocardiograms at Seoul National University Bundang Hospital, tertiary medical center in Korea, between May 2012 and June 2022. Additionally, we assessed the predictive value of AI-derived diastolic parameters and LVDF grades for a clinical endpoint, defined as a composite of all-cause death and hospitalization for heart failure, using Cox-regression risk modelling.</p><p><strong>Results: </strong>In an evaluation with 200 echocardiographic examinations (167 suspected diastolic dysfunction patients, 33 controls), it achieves an overall accuracy of 99.1% in identifying necessary views. Strong correlations (Pearson coefficient 0.901-0.959) were observed between AI-derived and manually-derived measurements of diastolic parameters, including LARS as well as conventional parameters. When following the guidelines, whether utilizing AI-derived or manually-derived parameters, the evaluation of LVDF consistently showed high concordance rates (94%). However, both methods exhibited lower concordance rates with the clinician's prior assessments (77.5% and 78.5%, respectively). Importantly, both AI-derived and manually-derived LVDF grades independently demonstrated significant prognostic value [adjusted hazard ratio (HR) =3.03; P=0.03 and adjusted HR =2.75; P=0.04, respectively] for predicting clinical outcome. In contrast, the clinician's prior grading lost its significance as a prognostic indicator after adjusting for clinical risk factors (adjusted HR =1.63; P=0.36). AI-derived LARS values significantly decreased with worsening LVDF (P for trend <0.001), and low LARS (<17%) was associated with increased risk for the clinical outcome (Log-rank P=0.04) relative to that for preserved LARS (≥17%).</p><p><strong>Conclusions: </strong>Our AI-based approach for automatic LVDF assessment on echocardiography is feasible, potentially enhancing clinical diagnosis and outcome prediction.</p>","PeriodicalId":9592,"journal":{"name":"Cardiovascular diagnosis and therapy","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11223940/pdf/","citationCount":"0","resultStr":"{\"title\":\"Artificial intelligence-enhanced automation of left ventricular diastolic assessment: a pilot study for feasibility, diagnostic validation, and outcome prediction.\",\"authors\":\"Jiesuck Park, Jaeik Jeon, Yeonyee E Yoon, Yeonggul Jang, Jiyeon Kim, Dawun Jeong, Jina Lee, Youngtaek Hong, Seongmin Ha, Arsanjani Reza, Hyung-Bok Park, Seung-Ah Lee, Hyejung Choi, Hong-Mi Choi, In-Chang Hwang, Goo-Yeong Cho, Hyuk-Jae Chang\",\"doi\":\"10.21037/cdt-24-25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Evaluating left ventricular diastolic function (LVDF) is crucial in echocardiography; however, the complexity and time demands of current guidelines challenge clinical use. This study aimed to develop an artificial intelligence (AI)-based framework for automatic LVDF assessment to reduce subjectivity and improve accuracy and outcome prediction.</p><p><strong>Methods: </strong>We developed an AI-based LVDF assessment framework using a nationwide echocardiographic dataset from five tertiary hospitals. This framework automatically identifies views, calculates diastolic parameters, including mitral inflow and annular velocities (E/A ratio, e' velocity, and E/e' ratio), maximal tricuspid regurgitation velocity, left atrial (LA) volume index, and left atrial reservoir strain (LARS). Subsequently, it grades LVDF according to guidelines. The AI-framework was validated on an external dataset composed of randomly screened 173 outpatients who underwent transthoracic echocardiography with suspicion for diastolic dysfunction and 33 individuals from medical check-ups with normal echocardiograms at Seoul National University Bundang Hospital, tertiary medical center in Korea, between May 2012 and June 2022. Additionally, we assessed the predictive value of AI-derived diastolic parameters and LVDF grades for a clinical endpoint, defined as a composite of all-cause death and hospitalization for heart failure, using Cox-regression risk modelling.</p><p><strong>Results: </strong>In an evaluation with 200 echocardiographic examinations (167 suspected diastolic dysfunction patients, 33 controls), it achieves an overall accuracy of 99.1% in identifying necessary views. Strong correlations (Pearson coefficient 0.901-0.959) were observed between AI-derived and manually-derived measurements of diastolic parameters, including LARS as well as conventional parameters. When following the guidelines, whether utilizing AI-derived or manually-derived parameters, the evaluation of LVDF consistently showed high concordance rates (94%). However, both methods exhibited lower concordance rates with the clinician's prior assessments (77.5% and 78.5%, respectively). Importantly, both AI-derived and manually-derived LVDF grades independently demonstrated significant prognostic value [adjusted hazard ratio (HR) =3.03; P=0.03 and adjusted HR =2.75; P=0.04, respectively] for predicting clinical outcome. In contrast, the clinician's prior grading lost its significance as a prognostic indicator after adjusting for clinical risk factors (adjusted HR =1.63; P=0.36). AI-derived LARS values significantly decreased with worsening LVDF (P for trend <0.001), and low LARS (<17%) was associated with increased risk for the clinical outcome (Log-rank P=0.04) relative to that for preserved LARS (≥17%).</p><p><strong>Conclusions: </strong>Our AI-based approach for automatic LVDF assessment on echocardiography is feasible, potentially enhancing clinical diagnosis and outcome prediction.</p>\",\"PeriodicalId\":9592,\"journal\":{\"name\":\"Cardiovascular diagnosis and therapy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11223940/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular diagnosis and therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.21037/cdt-24-25\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular diagnosis and therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/cdt-24-25","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Artificial intelligence-enhanced automation of left ventricular diastolic assessment: a pilot study for feasibility, diagnostic validation, and outcome prediction.
Background: Evaluating left ventricular diastolic function (LVDF) is crucial in echocardiography; however, the complexity and time demands of current guidelines challenge clinical use. This study aimed to develop an artificial intelligence (AI)-based framework for automatic LVDF assessment to reduce subjectivity and improve accuracy and outcome prediction.
Methods: We developed an AI-based LVDF assessment framework using a nationwide echocardiographic dataset from five tertiary hospitals. This framework automatically identifies views, calculates diastolic parameters, including mitral inflow and annular velocities (E/A ratio, e' velocity, and E/e' ratio), maximal tricuspid regurgitation velocity, left atrial (LA) volume index, and left atrial reservoir strain (LARS). Subsequently, it grades LVDF according to guidelines. The AI-framework was validated on an external dataset composed of randomly screened 173 outpatients who underwent transthoracic echocardiography with suspicion for diastolic dysfunction and 33 individuals from medical check-ups with normal echocardiograms at Seoul National University Bundang Hospital, tertiary medical center in Korea, between May 2012 and June 2022. Additionally, we assessed the predictive value of AI-derived diastolic parameters and LVDF grades for a clinical endpoint, defined as a composite of all-cause death and hospitalization for heart failure, using Cox-regression risk modelling.
Results: In an evaluation with 200 echocardiographic examinations (167 suspected diastolic dysfunction patients, 33 controls), it achieves an overall accuracy of 99.1% in identifying necessary views. Strong correlations (Pearson coefficient 0.901-0.959) were observed between AI-derived and manually-derived measurements of diastolic parameters, including LARS as well as conventional parameters. When following the guidelines, whether utilizing AI-derived or manually-derived parameters, the evaluation of LVDF consistently showed high concordance rates (94%). However, both methods exhibited lower concordance rates with the clinician's prior assessments (77.5% and 78.5%, respectively). Importantly, both AI-derived and manually-derived LVDF grades independently demonstrated significant prognostic value [adjusted hazard ratio (HR) =3.03; P=0.03 and adjusted HR =2.75; P=0.04, respectively] for predicting clinical outcome. In contrast, the clinician's prior grading lost its significance as a prognostic indicator after adjusting for clinical risk factors (adjusted HR =1.63; P=0.36). AI-derived LARS values significantly decreased with worsening LVDF (P for trend <0.001), and low LARS (<17%) was associated with increased risk for the clinical outcome (Log-rank P=0.04) relative to that for preserved LARS (≥17%).
Conclusions: Our AI-based approach for automatic LVDF assessment on echocardiography is feasible, potentially enhancing clinical diagnosis and outcome prediction.
期刊介绍:
The journal ''Cardiovascular Diagnosis and Therapy'' (Print ISSN: 2223-3652; Online ISSN: 2223-3660) accepts basic and clinical science submissions related to Cardiovascular Medicine and Surgery. The mission of the journal is the rapid exchange of scientific information between clinicians and scientists worldwide. To reach this goal, the journal will focus on novel media, using a web-based, digital format in addition to traditional print-version. This includes on-line submission, review, publication, and distribution. The digital format will also allow submission of extensive supporting visual material, both images and video. The website www.thecdt.org will serve as the central hub and also allow posting of comments and on-line discussion. The web-site of the journal will be linked to a number of international web-sites (e.g. www.dxy.cn), which will significantly expand the distribution of its contents.