{"title":"COMPASS-CAT 血栓风险评估量表预测癌症患者静脉血栓栓塞的准确性:一项荟萃分析。","authors":"Wei Zhou, Shujuan Chen, Jinhong Yang, Yihong Jiang, Shirong Fang","doi":"10.1007/s11239-024-03011-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This systematic review aims to assess the accuracy of the COMPASS-CAT tool in predicting venous thromboembolism (VTE) among cancer patients.</p><p><strong>Methods: </strong>Relevant studies were searched in PubMed, Web of Science, The Cochrane Library, Embase, CINAHL, OVID, CBM, CNKI, WanFang Data, and VIP database from their inception up to April 19, 2023. The quality of studies was appraised using the diagnostic test accuracy study bias assessment tool (QUADAS-2). Quantitative analysis was performed using Stata MP 17.0.</p><p><strong>Results: </strong>Thirteen studies involving 8,665 patients were included. Meta-analysis indicated that the COMPASS-CAT score had a pooled sensitivity of 0.76 [95%CI (0.61, 0.86)], specificity of 0.67 [95%CI (0.52, 0.79)], positive likelihood ratio of 2.3 [95%CI (1.7, 3.1)], negative likelihood ratio of 0.36 [95%CI (0.23, 0.54)], diagnostic odds ratio of 6 [95%CI (4, 10)], and an area under the Summary Receiver Operating Characteristic (SROC) curve (AUC) of 0.77 [95%CI (0.74, 0.81)]. Funnel plots indicated no publication bias. Meta-regression and subgroup analysis suggested that country and diagnostic setting might be potential sources of heterogeneity. The sensitivity of the COMPASS-CAT assessment tool in international outpatient settings was 0.94 with an AUC of 0.86, while in domestic inpatient settings, the sensitivity was 0.65 with an AUC of 0.78.</p><p><strong>Conclusion: </strong>The COMPASS-CAT score had a certain diagnostic value for VTE in cancer patients and can effectively identify patients at risk of VTE. Most studies focus on patients with lung cancer. Future research should investigate more tumor types, and high-quality, large-sample, multi-center prospective studies on larger populations with cancers are warranted.</p>","PeriodicalId":17546,"journal":{"name":"Journal of Thrombosis and Thrombolysis","volume":" ","pages":"1193-1205"},"PeriodicalIF":2.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of the COMPASS-CAT thrombosis risk assessment scale in predicting venous thromboembolism in cancer patients: a meta-analysis.\",\"authors\":\"Wei Zhou, Shujuan Chen, Jinhong Yang, Yihong Jiang, Shirong Fang\",\"doi\":\"10.1007/s11239-024-03011-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This systematic review aims to assess the accuracy of the COMPASS-CAT tool in predicting venous thromboembolism (VTE) among cancer patients.</p><p><strong>Methods: </strong>Relevant studies were searched in PubMed, Web of Science, The Cochrane Library, Embase, CINAHL, OVID, CBM, CNKI, WanFang Data, and VIP database from their inception up to April 19, 2023. The quality of studies was appraised using the diagnostic test accuracy study bias assessment tool (QUADAS-2). Quantitative analysis was performed using Stata MP 17.0.</p><p><strong>Results: </strong>Thirteen studies involving 8,665 patients were included. Meta-analysis indicated that the COMPASS-CAT score had a pooled sensitivity of 0.76 [95%CI (0.61, 0.86)], specificity of 0.67 [95%CI (0.52, 0.79)], positive likelihood ratio of 2.3 [95%CI (1.7, 3.1)], negative likelihood ratio of 0.36 [95%CI (0.23, 0.54)], diagnostic odds ratio of 6 [95%CI (4, 10)], and an area under the Summary Receiver Operating Characteristic (SROC) curve (AUC) of 0.77 [95%CI (0.74, 0.81)]. Funnel plots indicated no publication bias. Meta-regression and subgroup analysis suggested that country and diagnostic setting might be potential sources of heterogeneity. The sensitivity of the COMPASS-CAT assessment tool in international outpatient settings was 0.94 with an AUC of 0.86, while in domestic inpatient settings, the sensitivity was 0.65 with an AUC of 0.78.</p><p><strong>Conclusion: </strong>The COMPASS-CAT score had a certain diagnostic value for VTE in cancer patients and can effectively identify patients at risk of VTE. Most studies focus on patients with lung cancer. Future research should investigate more tumor types, and high-quality, large-sample, multi-center prospective studies on larger populations with cancers are warranted.</p>\",\"PeriodicalId\":17546,\"journal\":{\"name\":\"Journal of Thrombosis and Thrombolysis\",\"volume\":\" \",\"pages\":\"1193-1205\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thrombosis and Thrombolysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11239-024-03011-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thrombosis and Thrombolysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11239-024-03011-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Accuracy of the COMPASS-CAT thrombosis risk assessment scale in predicting venous thromboembolism in cancer patients: a meta-analysis.
Objective: This systematic review aims to assess the accuracy of the COMPASS-CAT tool in predicting venous thromboembolism (VTE) among cancer patients.
Methods: Relevant studies were searched in PubMed, Web of Science, The Cochrane Library, Embase, CINAHL, OVID, CBM, CNKI, WanFang Data, and VIP database from their inception up to April 19, 2023. The quality of studies was appraised using the diagnostic test accuracy study bias assessment tool (QUADAS-2). Quantitative analysis was performed using Stata MP 17.0.
Results: Thirteen studies involving 8,665 patients were included. Meta-analysis indicated that the COMPASS-CAT score had a pooled sensitivity of 0.76 [95%CI (0.61, 0.86)], specificity of 0.67 [95%CI (0.52, 0.79)], positive likelihood ratio of 2.3 [95%CI (1.7, 3.1)], negative likelihood ratio of 0.36 [95%CI (0.23, 0.54)], diagnostic odds ratio of 6 [95%CI (4, 10)], and an area under the Summary Receiver Operating Characteristic (SROC) curve (AUC) of 0.77 [95%CI (0.74, 0.81)]. Funnel plots indicated no publication bias. Meta-regression and subgroup analysis suggested that country and diagnostic setting might be potential sources of heterogeneity. The sensitivity of the COMPASS-CAT assessment tool in international outpatient settings was 0.94 with an AUC of 0.86, while in domestic inpatient settings, the sensitivity was 0.65 with an AUC of 0.78.
Conclusion: The COMPASS-CAT score had a certain diagnostic value for VTE in cancer patients and can effectively identify patients at risk of VTE. Most studies focus on patients with lung cancer. Future research should investigate more tumor types, and high-quality, large-sample, multi-center prospective studies on larger populations with cancers are warranted.
期刊介绍:
The Journal of Thrombosis and Thrombolysis is a long-awaited resource for contemporary cardiologists, hematologists, vascular medicine specialists and clinician-scientists actively involved in treatment decisions and clinical investigation of thrombotic disorders involving the cardiovascular and cerebrovascular systems. The principal focus of the Journal centers on the pathobiology of thrombosis and vascular disorders and the use of anticoagulants, platelet antagonists, cell-based therapies and interventions in scientific investigation, clinical-translational research and patient care.
The Journal will publish original work which emphasizes the interface between fundamental scientific principles and clinical investigation, stimulating an interdisciplinary and scholarly dialogue in thrombosis and vascular science. Published works will also define platforms for translational research, drug development, clinical trials and patient-directed applications. The Journal of Thrombosis and Thrombolysis'' integrated format will expand the reader''s knowledge base and provide important insights for both the investigation and direct clinical application of the most rapidly growing fields in medicine-thrombosis and vascular science.