新型铰链式全膝关节置换系统在各种复杂膝关节情况下的作用:病例系列。

IF 0.8 Q4 SURGERY Surgical technology international Pub Date : 2024-07-15 DOI:10.52198/24.STI.44.OS1799
Daniel Hameed, Bryan D Springer, Arthur L Malkani, Michael A Mont
{"title":"新型铰链式全膝关节置换系统在各种复杂膝关节情况下的作用:病例系列。","authors":"Daniel Hameed, Bryan D Springer, Arthur L Malkani, Michael A Mont","doi":"10.52198/24.STI.44.OS1799","DOIUrl":null,"url":null,"abstract":"<p><p>Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.</p>","PeriodicalId":22194,"journal":{"name":"Surgical technology international","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Role of a New Hinged Total Knee Arthroplasty System for Use in a Variety of Complex Knee Scenarios: A Case Series.\",\"authors\":\"Daniel Hameed, Bryan D Springer, Arthur L Malkani, Michael A Mont\",\"doi\":\"10.52198/24.STI.44.OS1799\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.</p>\",\"PeriodicalId\":22194,\"journal\":{\"name\":\"Surgical technology international\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical technology international\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52198/24.STI.44.OS1799\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical technology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52198/24.STI.44.OS1799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

铰链膝关节置换术通常用于膝关节周围存在严重韧带缺损或骨缺失的情况。铰链式膝关节假体适用于有严重畸形的原生膝关节和翻修过程中。它们还可用作股骨远端切除术后的挽救手术。新的模块化铰链装置系统,即Triathlon铰链膝(THK)系统(史赛克公司,马华,新泽西州),反映了第三代设计的进步,并通过与Triathlon全稳定(TS)系统(史赛克公司,马华,新泽西州)和全球模块化置换系统(GMRS,史赛克公司,马华,新泽西州)的简化整合,提高了手术的灵活性。此外,作为 THK 的一部分,Triathlon 翻修型胫骨基板(史赛克,马华,新泽西州)也已推出,它与模块化旋转铰链(MRH,史赛克,马华,新泽西州)股骨兼容,这使得翻修型基板可以取代现有的胫骨组件,同时保留现有的 MRH 股骨组件。Triathlon 翻修型胫骨基板使矫形外科医生能够在不改变胫骨基板的情况下使用约束或铰链假体,包括远端和全股骨置换选择。这是因为 TS、MRH、THK 和 GMRS 股骨与新型 Triathlon 翻修型胫骨基板兼容。此外,该系统还可使用骺锥构造进行增强,为重建提供稳定的基础。本报告探讨了新型模块化铰链装置系统在各种情况下的应用,首先是(1)复杂的初次铰链膝关节置换术,然后是翻修铰链膝关节置换术病例,包括(2)内侧副韧带(MCL)功能障碍的 TKA 失败病例、(3)TKA术后严重关节纤维化,(4)因假体关节感染而进行翻修,(5)外展机制缺陷,(6)关节纤维化伴外展机制破坏,最后是(7)TKA失败后因假体周围骨折而进行股骨远端关节置换术的病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Role of a New Hinged Total Knee Arthroplasty System for Use in a Variety of Complex Knee Scenarios: A Case Series.

Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
141
期刊最新文献
Robotic Assisted Lapendoscopic Single-Site Surgery for Ileal Deep Endometriosis. A Case Report and Review of Literature. Robotic versus Laparoscopic Partial Nephrectomy: A Systematic Review and Meta-Analysis of Randomised Trials. Cardiophrenic Lymph Node Resection Through Abdominal Subxiphoid Approach: Surgical Technique. What Happens to Endometriosis During the Menstrual Cycle? Robotic Total Knee Arthroplasty is Associated with Thinner and Less Constrained Polyethylene Inserts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1