2018-2023年中国福建省临床实验室检验全过程质量指标调查。

IF 3.8 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY Clinical chemistry and laboratory medicine Pub Date : 2024-07-12 DOI:10.1515/cclm-2024-0495
Yao Li, Falin Chen, Xijun Chen
{"title":"2018-2023年中国福建省临床实验室检验全过程质量指标调查。","authors":"Yao Li, Falin Chen, Xijun Chen","doi":"10.1515/cclm-2024-0495","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study investigates the application of 15 Quality Indicators (QIs) in clinical laboratories in Fujian Province, China, from 2018 to 2023. It identifies the main causes of laboratory errors and explores issues in the application of QIs, providing a reference for establishing provincial state-of-the-art and operational quality specifications (QSs).</p><p><strong>Methods: </strong>All clinical laboratories in Fujian Province were organized to submit general information and original QIs data through the online External Quality Assessment (EQA) system of the National Clinical Laboratory Center (NCCL) for a survey of 15 QIs. Data from 2018 to 2023 were downloaded for statistical analysis, and the current QSs for the 15 QIs in Fujian Province were compared and analyzed with those published by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group on Laboratory Errors and Patient Safety (WG-LEPS).</p><p><strong>Results: </strong>QIs data from 542 clinical laboratories were collected. The survey on data sources showed that the number of laboratories recording QIs data using Laboratory Information Systems (LIS) increased annually, but the growth was modest and the proportion was less than 50 %. Among the laboratories using LIS to record QIs data, 133 continuously participated in this survey for six years, reporting different QIs. Over the six years, all reported QIs showed significant improvement or at least remained stable. The best median Sigma (σ) metrics were for the percentage of critical values notification and timely critical values notification, reaching 6σ, followed by the percentage of incorrect laboratory reports, with σ metrics ranging from 4.9σ to 5.1σ. In contrast, the percentage of tests covered by internal quality control (IQC) (1.5σ-1.7σ) and inter-laboratory comparison (0.1σ) remained consistently low. Compared to the QSs published by IFCC WG-LEPS, the QSs for the 15 QIs in Fujian Province in 2023 were stricter or roughly equivalent, except for the percentage of incorrect laboratory reports (Fujian Province: 0-0.221, IFCC WG-LEPS: 0-0.03).</p><p><strong>Conclusions: </strong>1. The application of QIs has significantly improved the quality of testing in clinical laboratories in Fujian Province, but the percentage of tests covered by IQC and inter-laboratory comparison remain low; 2. Effective application of QIs requires the establishment of comprehensive LIS, unified calculation standards, and other supporting measures.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The surveys on quality indicators for the total testing process in clinical laboratories of Fujian Province in China from 2018 to 2023.\",\"authors\":\"Yao Li, Falin Chen, Xijun Chen\",\"doi\":\"10.1515/cclm-2024-0495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study investigates the application of 15 Quality Indicators (QIs) in clinical laboratories in Fujian Province, China, from 2018 to 2023. It identifies the main causes of laboratory errors and explores issues in the application of QIs, providing a reference for establishing provincial state-of-the-art and operational quality specifications (QSs).</p><p><strong>Methods: </strong>All clinical laboratories in Fujian Province were organized to submit general information and original QIs data through the online External Quality Assessment (EQA) system of the National Clinical Laboratory Center (NCCL) for a survey of 15 QIs. Data from 2018 to 2023 were downloaded for statistical analysis, and the current QSs for the 15 QIs in Fujian Province were compared and analyzed with those published by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group on Laboratory Errors and Patient Safety (WG-LEPS).</p><p><strong>Results: </strong>QIs data from 542 clinical laboratories were collected. The survey on data sources showed that the number of laboratories recording QIs data using Laboratory Information Systems (LIS) increased annually, but the growth was modest and the proportion was less than 50 %. Among the laboratories using LIS to record QIs data, 133 continuously participated in this survey for six years, reporting different QIs. Over the six years, all reported QIs showed significant improvement or at least remained stable. The best median Sigma (σ) metrics were for the percentage of critical values notification and timely critical values notification, reaching 6σ, followed by the percentage of incorrect laboratory reports, with σ metrics ranging from 4.9σ to 5.1σ. In contrast, the percentage of tests covered by internal quality control (IQC) (1.5σ-1.7σ) and inter-laboratory comparison (0.1σ) remained consistently low. Compared to the QSs published by IFCC WG-LEPS, the QSs for the 15 QIs in Fujian Province in 2023 were stricter or roughly equivalent, except for the percentage of incorrect laboratory reports (Fujian Province: 0-0.221, IFCC WG-LEPS: 0-0.03).</p><p><strong>Conclusions: </strong>1. The application of QIs has significantly improved the quality of testing in clinical laboratories in Fujian Province, but the percentage of tests covered by IQC and inter-laboratory comparison remain low; 2. Effective application of QIs requires the establishment of comprehensive LIS, unified calculation standards, and other supporting measures.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2024-0495\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-0495","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究调查了2018年至2023年中国福建省临床实验室15项质量指标(QIs)的应用情况。该研究确定了实验室差错的主要原因,并探讨了QIs应用中存在的问题,为制定省级最先进的操作质量规范(QSs)提供参考:组织福建省所有临床实验室通过国家临床检验中心(NCCL)外部质量评价(EQA)在线系统提交一般信息和原始QIs数据,对15项QIs进行调查。下载2018年至2023年的数据进行统计分析,并将福建省15个QIs的现行QS与国际临床化学与检验医学联合会(IFCC)实验室差错与患者安全工作组(WG-LEPS)公布的QS进行对比分析:结果:共收集了542家临床实验室的QIs数据。对数据来源的调查显示,使用实验室信息系统(LIS)记录QIs数据的实验室数量逐年增加,但增长幅度不大,所占比例不到50%。在使用实验室信息系统(LIS)记录质量指标数据的实验室中,有 133 家连续六年参加了这项调查,报告了不同的质量指标。在这六年中,所有报告的质量指标均有显著改善或至少保持稳定。中值西格玛(σ)指标最好的是关键值通知和及时关键值通知的百分比,达到 6σ,其次是不正确实验室报告的百分比,σ指标从 4.9σ 到 5.1σ不等。相比之下,内部质量控制(IQC)(1.5σ-1.7σ)和实验室间比对(0.1σ)所覆盖的检测比例始终较低。与IFCC WG-LEPS公布的质量标准相比,2023年福建省15个质量指标的质量标准除实验室报告错误率(福建省:0-0.221,IFCC WG-LEPS:0-0.03)外,其他指标均较严格或基本相当:1.1.质量指标的应用显著提高了福建省临床实验室的检验质量,但IQC和实验室间比对所覆盖的检验项目比例仍然较低;2.质量指标的有效应用需要建立完善的LIS、统一的计算标准和其他配套措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The surveys on quality indicators for the total testing process in clinical laboratories of Fujian Province in China from 2018 to 2023.

Objectives: This study investigates the application of 15 Quality Indicators (QIs) in clinical laboratories in Fujian Province, China, from 2018 to 2023. It identifies the main causes of laboratory errors and explores issues in the application of QIs, providing a reference for establishing provincial state-of-the-art and operational quality specifications (QSs).

Methods: All clinical laboratories in Fujian Province were organized to submit general information and original QIs data through the online External Quality Assessment (EQA) system of the National Clinical Laboratory Center (NCCL) for a survey of 15 QIs. Data from 2018 to 2023 were downloaded for statistical analysis, and the current QSs for the 15 QIs in Fujian Province were compared and analyzed with those published by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group on Laboratory Errors and Patient Safety (WG-LEPS).

Results: QIs data from 542 clinical laboratories were collected. The survey on data sources showed that the number of laboratories recording QIs data using Laboratory Information Systems (LIS) increased annually, but the growth was modest and the proportion was less than 50 %. Among the laboratories using LIS to record QIs data, 133 continuously participated in this survey for six years, reporting different QIs. Over the six years, all reported QIs showed significant improvement or at least remained stable. The best median Sigma (σ) metrics were for the percentage of critical values notification and timely critical values notification, reaching 6σ, followed by the percentage of incorrect laboratory reports, with σ metrics ranging from 4.9σ to 5.1σ. In contrast, the percentage of tests covered by internal quality control (IQC) (1.5σ-1.7σ) and inter-laboratory comparison (0.1σ) remained consistently low. Compared to the QSs published by IFCC WG-LEPS, the QSs for the 15 QIs in Fujian Province in 2023 were stricter or roughly equivalent, except for the percentage of incorrect laboratory reports (Fujian Province: 0-0.221, IFCC WG-LEPS: 0-0.03).

Conclusions: 1. The application of QIs has significantly improved the quality of testing in clinical laboratories in Fujian Province, but the percentage of tests covered by IQC and inter-laboratory comparison remain low; 2. Effective application of QIs requires the establishment of comprehensive LIS, unified calculation standards, and other supporting measures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
期刊最新文献
Iron deficiency and iron deficiency anemia in transgender populations: what's different? CD34+ progenitor cells meet metrology. Expanded carrier screening for 224 monogenic disease genes in 1,499 Chinese couples: a single-center study. Allowable total error in CD34 cell analysis by flow cytometry based on state of the art using Spanish EQAS data. Comparison of capillary finger stick and venous blood sampling for 34 routine chemistry analytes: potential for in the hospital and remote blood sampling.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1