为修复黄斑-关闭流变性视网膜脱离而进行的虹膜切除术中,初次植入和延迟植入后的眼内晶体倾斜和分散。

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY Indian Journal of Ophthalmology Pub Date : 2024-11-01 Epub Date: 2024-07-11 DOI:10.4103/IJO.IJO_3192_23
Qingchen Li, Zhou Yang, Rui Liu
{"title":"为修复黄斑-关闭流变性视网膜脱离而进行的虹膜切除术中,初次植入和延迟植入后的眼内晶体倾斜和分散。","authors":"Qingchen Li, Zhou Yang, Rui Liu","doi":"10.4103/IJO.IJO_3192_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the tilt and decentration of intraocular lenses (IOLs) in eyes that underwent phacovitrectomy for macula-off rhegmatogenous retinal detachment (RRD) repair.</p><p><strong>Methods: </strong>In this retrospective cohort study, 63 patients with macula-off RRD who underwent phacovitrectomy were enrolled and divided into a primary implantation group (group A) and a delayed implantation group (group B) according to the time of IOL implantation. Routine ocular examinations, including optometry, were performed, and the IOL tilt and decentration were measured. Postoperative refractive prediction error and IOL tilt and decentration were compared between the two groups, and the relevant factors of IOL positions were analyzed.</p><p><strong>Results: </strong>The mean spherical refractive prediction error (MSE) was - 0.53 ± 0.39 D in group A and - 0.09 ± 0.55 in group B. The mean absolute spherical refractive prediction error (MASE) was 0.61 ± 0.23 D in group A and 0.50 ± 0.22 D in group B. The difference in MSE ( t = -3.623, P < 0.05) but not in MASE (t = 1.866, P = 0.067) between the two groups was significant. The mean IOL tilt and mean decentration were 8.54° ±3.65° and 0.55 ± 0.18 mm in group A and 10.62° ±3.29° and 0.66 ± 0.14 mm, respectively, in Group B. Differences in tilt ( t = -2.373, P < 0.05) and decentration ( t = -2.698, P < 0.05) between the two groups were both significant. In group B, the mean time interval between phacovitrectomy and IOL implantation (T V-I ) was 25.2 ± 6.9 weeks, and the absolute values of both IOL tilt and decentration were positively correlated with T V-I .</p><p><strong>Conclusion: </strong>In phacovitrectomy for macula-off RRD repair, primary IOL implantation leads to a postoperative myopic shift, while delayed IOL implantation may cause greater IOL tilt and decentration.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraocular lens tilt and decentration after primary and delayed implantation in phacovitrectomy for macula-off rhegmatogenous retinal detachment repair.\",\"authors\":\"Qingchen Li, Zhou Yang, Rui Liu\",\"doi\":\"10.4103/IJO.IJO_3192_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the tilt and decentration of intraocular lenses (IOLs) in eyes that underwent phacovitrectomy for macula-off rhegmatogenous retinal detachment (RRD) repair.</p><p><strong>Methods: </strong>In this retrospective cohort study, 63 patients with macula-off RRD who underwent phacovitrectomy were enrolled and divided into a primary implantation group (group A) and a delayed implantation group (group B) according to the time of IOL implantation. Routine ocular examinations, including optometry, were performed, and the IOL tilt and decentration were measured. Postoperative refractive prediction error and IOL tilt and decentration were compared between the two groups, and the relevant factors of IOL positions were analyzed.</p><p><strong>Results: </strong>The mean spherical refractive prediction error (MSE) was - 0.53 ± 0.39 D in group A and - 0.09 ± 0.55 in group B. The mean absolute spherical refractive prediction error (MASE) was 0.61 ± 0.23 D in group A and 0.50 ± 0.22 D in group B. The difference in MSE ( t = -3.623, P < 0.05) but not in MASE (t = 1.866, P = 0.067) between the two groups was significant. The mean IOL tilt and mean decentration were 8.54° ±3.65° and 0.55 ± 0.18 mm in group A and 10.62° ±3.29° and 0.66 ± 0.14 mm, respectively, in Group B. Differences in tilt ( t = -2.373, P < 0.05) and decentration ( t = -2.698, P < 0.05) between the two groups were both significant. In group B, the mean time interval between phacovitrectomy and IOL implantation (T V-I ) was 25.2 ± 6.9 weeks, and the absolute values of both IOL tilt and decentration were positively correlated with T V-I .</p><p><strong>Conclusion: </strong>In phacovitrectomy for macula-off RRD repair, primary IOL implantation leads to a postoperative myopic shift, while delayed IOL implantation may cause greater IOL tilt and decentration.</p>\",\"PeriodicalId\":13329,\"journal\":{\"name\":\"Indian Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/IJO.IJO_3192_23\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_3192_23","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估因黄斑-关闭性流变性视网膜脱离(RRD)修复而接受虹膜切除术的眼球中人工晶体(IOL)的倾斜和分散情况:在这项回顾性队列研究中,共纳入了 63 名接受了相控阵切除术的黄斑脱落 RRD 患者,并根据人工晶体植入的时间分为初次植入组(A 组)和延迟植入组(B 组)。进行常规眼部检查,包括验光,并测量人工晶体的倾斜度和分散度。比较两组患者术后的屈光预测误差、人工晶体倾斜度和分散度,并分析人工晶体位置的相关因素:A组的平均球面屈光预测误差(MSE)为- 0.53 ± 0.39 D,B组为- 0.09 ± 0.55 D;A组的平均绝对球面屈光预测误差(MASE)为0.61 ± 0.23 D,B组为0.50 ± 0.22 D;两组间的MSE(t = -3.623,P < 0.05)差异显著,但MASE(t = 1.866,P = 0.067)差异不显著。A 组的平均人工晶体倾斜度和平均分散度分别为 8.54° ±3.65° 和 0.55 ± 0.18 mm,B 组分别为 10.62° ±3.29° 和 0.66 ± 0.14 mm,两组之间的倾斜度(t = -2.373,P < 0.05)和分散度(t = -2.698,P < 0.05)差异均有显著性。在 B 组中,幽门切除术与人工晶体植入术之间的平均时间间隔(TV-I)为 25.2 ± 6.9 周,人工晶体倾斜度和分散度的绝对值与 TV-I 呈正相关:结论:在用于黄斑-关闭性RRD修复的相切除术中,初次植入人工晶体会导致术后近视偏移,而延迟植入人工晶体可能会导致人工晶体倾斜和下垂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intraocular lens tilt and decentration after primary and delayed implantation in phacovitrectomy for macula-off rhegmatogenous retinal detachment repair.

Purpose: To evaluate the tilt and decentration of intraocular lenses (IOLs) in eyes that underwent phacovitrectomy for macula-off rhegmatogenous retinal detachment (RRD) repair.

Methods: In this retrospective cohort study, 63 patients with macula-off RRD who underwent phacovitrectomy were enrolled and divided into a primary implantation group (group A) and a delayed implantation group (group B) according to the time of IOL implantation. Routine ocular examinations, including optometry, were performed, and the IOL tilt and decentration were measured. Postoperative refractive prediction error and IOL tilt and decentration were compared between the two groups, and the relevant factors of IOL positions were analyzed.

Results: The mean spherical refractive prediction error (MSE) was - 0.53 ± 0.39 D in group A and - 0.09 ± 0.55 in group B. The mean absolute spherical refractive prediction error (MASE) was 0.61 ± 0.23 D in group A and 0.50 ± 0.22 D in group B. The difference in MSE ( t = -3.623, P < 0.05) but not in MASE (t = 1.866, P = 0.067) between the two groups was significant. The mean IOL tilt and mean decentration were 8.54° ±3.65° and 0.55 ± 0.18 mm in group A and 10.62° ±3.29° and 0.66 ± 0.14 mm, respectively, in Group B. Differences in tilt ( t = -2.373, P < 0.05) and decentration ( t = -2.698, P < 0.05) between the two groups were both significant. In group B, the mean time interval between phacovitrectomy and IOL implantation (T V-I ) was 25.2 ± 6.9 weeks, and the absolute values of both IOL tilt and decentration were positively correlated with T V-I .

Conclusion: In phacovitrectomy for macula-off RRD repair, primary IOL implantation leads to a postoperative myopic shift, while delayed IOL implantation may cause greater IOL tilt and decentration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
期刊最新文献
Association between gut microbiota and central retinal artery occlusion: A two-sample Mendelian randomization study. Clinical outcomes of topography-guided versus wavefront-optimized LASIK for correction of myopia and compound myopic astigmatism. Accuracy of Intraocular lens power calculation in pediatric traumatic cataract. Alterations in the tear film and ocular surface in pediatric migraine patients. Guidelines for setting up low-vision and rehabilitation services in India.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1