{"title":"用于核磁共振光谱和成像应用的自动超极化 129Xe 气体发生器","authors":"Mineyuki Hattori ,&nbsp;Takashi Hiraga ,&nbsp;Kazuhiro Homma ,&nbsp;Norio Ohtake","doi":"10.1016/j.jmro.2024.100154","DOIUrl":null,"url":null,"abstract":"<div><p>We describe a method and an apparatus for producing hyperpolarized (HP) Xe gas of high concentration without Xe condensation. The HP Xe generator works under atmospheric pressure and employs a quasi-continuous method to provide a continuous supply of HP Xe gas by adopting technologies for supplying a highly pure gas, a gas control system and precise pressure control. The apparatus has a glass cell containing solid Rb metal and solid Xe in vacuum at a low temperature and is heated so that the Xe becomes a gas and Rb exists in a gas-liquid mixture. Then a magnetic field is applied with laser beam irradiation to produce polarized Xe gas of high concentration. The device was evaluated using a 2T magnetic resonance imaging (MRI) scanner. Long-term experimental operation demonstrated the continuous collection of 30 ml syringes of HP Xe gas with a sufficient polarization rate for fast one scan acquisition. A practical device for the automated manufacture of HP <sup>129</sup>Xe gas was thus successfully developed.</p></div>","PeriodicalId":365,"journal":{"name":"Journal of Magnetic Resonance Open","volume":"20 ","pages":"Article 100154"},"PeriodicalIF":2.6240,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666441024000098/pdfft?md5=b9d93058d60dbb47913e59da366288d6&pid=1-s2.0-S2666441024000098-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Automated hyperpolarized 129Xe gas generator for nuclear magnetic resonance spectroscopy and imaging applications\",\"authors\":\"Mineyuki Hattori ,&nbsp;Takashi Hiraga ,&nbsp;Kazuhiro Homma ,&nbsp;Norio Ohtake\",\"doi\":\"10.1016/j.jmro.2024.100154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>We describe a method and an apparatus for producing hyperpolarized (HP) Xe gas of high concentration without Xe condensation. The HP Xe generator works under atmospheric pressure and employs a quasi-continuous method to provide a continuous supply of HP Xe gas by adopting technologies for supplying a highly pure gas, a gas control system and precise pressure control. The apparatus has a glass cell containing solid Rb metal and solid Xe in vacuum at a low temperature and is heated so that the Xe becomes a gas and Rb exists in a gas-liquid mixture. Then a magnetic field is applied with laser beam irradiation to produce polarized Xe gas of high concentration. The device was evaluated using a 2T magnetic resonance imaging (MRI) scanner. Long-term experimental operation demonstrated the continuous collection of 30 ml syringes of HP Xe gas with a sufficient polarization rate for fast one scan acquisition. A practical device for the automated manufacture of HP <sup>129</sup>Xe gas was thus successfully developed.</p></div>\",\"PeriodicalId\":365,\"journal\":{\"name\":\"Journal of Magnetic Resonance Open\",\"volume\":\"20 \",\"pages\":\"Article 100154\"},\"PeriodicalIF\":2.6240,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666441024000098/pdfft?md5=b9d93058d60dbb47913e59da366288d6&pid=1-s2.0-S2666441024000098-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Open\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666441024000098\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Open","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666441024000098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们介绍了一种生产高浓度超极化(HP)氙气而不产生氙气冷凝的方法和设备。HP Xe 发生器在大气压力下工作,采用准连续方法,通过采用供应高纯气体、气体控制系统和精确压力控制技术,连续供应 HP Xe 气体。该设备有一个玻璃池,内装固体铷金属和固体氙,在低温真空中加热,使氙变成气体,铷以气液混合物的形式存在。然后在激光束照射下施加磁场,产生高浓度的极化 Xe 气体。该装置利用 2T 磁共振成像(MRI)扫描仪进行了评估。长期的实验操作证明,该装置能连续收集 30 毫升注射器中的高浓度氙气,且极化率足以满足快速扫描采集的需要。由此,一种用于自动制造 HP 129Xe 气体的实用装置被成功开发出来。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automated hyperpolarized 129Xe gas generator for nuclear magnetic resonance spectroscopy and imaging applications

We describe a method and an apparatus for producing hyperpolarized (HP) Xe gas of high concentration without Xe condensation. The HP Xe generator works under atmospheric pressure and employs a quasi-continuous method to provide a continuous supply of HP Xe gas by adopting technologies for supplying a highly pure gas, a gas control system and precise pressure control. The apparatus has a glass cell containing solid Rb metal and solid Xe in vacuum at a low temperature and is heated so that the Xe becomes a gas and Rb exists in a gas-liquid mixture. Then a magnetic field is applied with laser beam irradiation to produce polarized Xe gas of high concentration. The device was evaluated using a 2T magnetic resonance imaging (MRI) scanner. Long-term experimental operation demonstrated the continuous collection of 30 ml syringes of HP Xe gas with a sufficient polarization rate for fast one scan acquisition. A practical device for the automated manufacture of HP 129Xe gas was thus successfully developed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
0
期刊最新文献
Improved 2D hydride detection for NMR-chemosensing via p‐H2 Hyperpolarization A practical guide to metal ions dynamic nuclear polarization in materials science Current state of the art of analyte scope in urine metabolome analysis by non-hydrogenative PHIP Natural abundance 195Pt-13C correlation NMR spectroscopy on surfaces enabled by fast MAS dynamic nuclear polarization Nuclear hyperpolarization in electron-transfer proteins: Revealing unexpected light-induced 15N signals with field-cycling magic-angle spinning NMR
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1