{"title":"血流逆转情况下的 CAS 结果及颈内动脉术中血流分析","authors":"Daizo Ishii , Takeshi Hara , Masashi Kuwabara , Hiroshi Kondo , Shinji Kume , Nobutaka Horie","doi":"10.1016/j.clineuro.2024.108443","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Carotid artery stenting (CAS) under flow reversal with dual protection using a proximal balloon and distal filter has been an established procedure for internal carotid artery (ICA) stenosis. This study investigates the effect of external carotid artery (ECA) occlusion on outcomes of CAS and ICA flow under flow reversal.</p></div><div><h3>Methods</h3><p>We reviewed 231 cases of CAS under flow reversal with ECA occlusion and 32 without. In the last 14 of 32 cases, the flow in the ICA under flow reversal was analyzed by ultrasound. The collateral index, which was defined as the total value of the maximum diameters of the ipsilateral anterior cerebral artery at the A1 segment and the anterior communicating artery, as well as those of the ipsilateral posterior cerebral artery at the P1 segment and the ipsilateral posterior communicating artery, and the maximum diameter of the ipsilateral ECA were correlated with the flow direction in the ICA.</p></div><div><h3>Results</h3><p>There was no significant difference in the outcome of CAS between the groups with or without ECA occlusion. Among the 14 cases without ECA occlusion, antegrade flow in the ICA was observed in 6 cases (42.9 %). The group with the antegrade flow in the ICA exhibited a significantly lower collateral index (5.08±0.33 vs 6.71±0.28, <em>p</em>=0.01) and a significantly larger ECA diameter (4.66±0.51 mm vs 3.21±1.24 mm, <em>p</em>=0.01) than the group with the stagnant or retrograde flow in the ICA.</p></div><div><h3>Conclusions</h3><p>The outcomes of CAS under flow reversal were acceptable even without ECA occlusion. The ECA occlusion may not be necessary for CAS under dual protection; however, distal filter protection should be used even under flow reversal.</p></div>","PeriodicalId":10385,"journal":{"name":"Clinical Neurology and Neurosurgery","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcome of CAS under flow reversal and analysis for the intraprocedural flow of internal carotid artery\",\"authors\":\"Daizo Ishii , Takeshi Hara , Masashi Kuwabara , Hiroshi Kondo , Shinji Kume , Nobutaka Horie\",\"doi\":\"10.1016/j.clineuro.2024.108443\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>Carotid artery stenting (CAS) under flow reversal with dual protection using a proximal balloon and distal filter has been an established procedure for internal carotid artery (ICA) stenosis. This study investigates the effect of external carotid artery (ECA) occlusion on outcomes of CAS and ICA flow under flow reversal.</p></div><div><h3>Methods</h3><p>We reviewed 231 cases of CAS under flow reversal with ECA occlusion and 32 without. In the last 14 of 32 cases, the flow in the ICA under flow reversal was analyzed by ultrasound. The collateral index, which was defined as the total value of the maximum diameters of the ipsilateral anterior cerebral artery at the A1 segment and the anterior communicating artery, as well as those of the ipsilateral posterior cerebral artery at the P1 segment and the ipsilateral posterior communicating artery, and the maximum diameter of the ipsilateral ECA were correlated with the flow direction in the ICA.</p></div><div><h3>Results</h3><p>There was no significant difference in the outcome of CAS between the groups with or without ECA occlusion. Among the 14 cases without ECA occlusion, antegrade flow in the ICA was observed in 6 cases (42.9 %). The group with the antegrade flow in the ICA exhibited a significantly lower collateral index (5.08±0.33 vs 6.71±0.28, <em>p</em>=0.01) and a significantly larger ECA diameter (4.66±0.51 mm vs 3.21±1.24 mm, <em>p</em>=0.01) than the group with the stagnant or retrograde flow in the ICA.</p></div><div><h3>Conclusions</h3><p>The outcomes of CAS under flow reversal were acceptable even without ECA occlusion. The ECA occlusion may not be necessary for CAS under dual protection; however, distal filter protection should be used even under flow reversal.</p></div>\",\"PeriodicalId\":10385,\"journal\":{\"name\":\"Clinical Neurology and Neurosurgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Neurology and Neurosurgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0303846724003305\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurology and Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0303846724003305","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的颈内动脉(ICA)狭窄患者在血流逆转情况下使用近端球囊和远端过滤器双重保护进行颈动脉支架置入术(CAS)已经是一种成熟的手术方法。本研究探讨了颈外动脉(ECA)闭塞对CAS术后效果和血流逆转下ICA血流的影响。在 32 例中的最后 14 例中,我们通过超声波分析了血流逆转下 ICA 的血流情况。侧支指数(定义为同侧大脑前动脉 A1 段和前交通动脉最大直径的总值,以及同侧大脑后动脉 P1 段和同侧后交通动脉最大直径的总值)和同侧 ECA 的最大直径与 ICA 的血流方向相关。在 14 例无 ECA 闭塞的病例中,有 6 例(42.9%)观察到 ICA 血流逆行。ICA 血流逆行组的侧支指数(5.08±0.33 vs 6.71±0.28,P=0.01)和 ECA 直径(4.66±0.51 mm vs 3.21±1.24 mm,P=0.01)明显低于 ICA 血流停滞或逆行组。双重保护下的 CAS 可能不需要 ECA 闭塞;但是,即使在血流逆转的情况下,也应使用远端滤器保护。
Outcome of CAS under flow reversal and analysis for the intraprocedural flow of internal carotid artery
Objective
Carotid artery stenting (CAS) under flow reversal with dual protection using a proximal balloon and distal filter has been an established procedure for internal carotid artery (ICA) stenosis. This study investigates the effect of external carotid artery (ECA) occlusion on outcomes of CAS and ICA flow under flow reversal.
Methods
We reviewed 231 cases of CAS under flow reversal with ECA occlusion and 32 without. In the last 14 of 32 cases, the flow in the ICA under flow reversal was analyzed by ultrasound. The collateral index, which was defined as the total value of the maximum diameters of the ipsilateral anterior cerebral artery at the A1 segment and the anterior communicating artery, as well as those of the ipsilateral posterior cerebral artery at the P1 segment and the ipsilateral posterior communicating artery, and the maximum diameter of the ipsilateral ECA were correlated with the flow direction in the ICA.
Results
There was no significant difference in the outcome of CAS between the groups with or without ECA occlusion. Among the 14 cases without ECA occlusion, antegrade flow in the ICA was observed in 6 cases (42.9 %). The group with the antegrade flow in the ICA exhibited a significantly lower collateral index (5.08±0.33 vs 6.71±0.28, p=0.01) and a significantly larger ECA diameter (4.66±0.51 mm vs 3.21±1.24 mm, p=0.01) than the group with the stagnant or retrograde flow in the ICA.
Conclusions
The outcomes of CAS under flow reversal were acceptable even without ECA occlusion. The ECA occlusion may not be necessary for CAS under dual protection; however, distal filter protection should be used even under flow reversal.
期刊介绍:
Clinical Neurology and Neurosurgery is devoted to publishing papers and reports on the clinical aspects of neurology and neurosurgery. It is an international forum for papers of high scientific standard that are of interest to Neurologists and Neurosurgeons world-wide.