利用平板电脑技术开发标准化护理交接:质量改进计划。

Pub Date : 2024-07-01 Epub Date: 2024-07-04 DOI:10.1097/JTN.0000000000000801
Briana R Miller, Kimberly A Maye, Frances D Charlton
{"title":"利用平板电脑技术开发标准化护理交接:质量改进计划。","authors":"Briana R Miller, Kimberly A Maye, Frances D Charlton","doi":"10.1097/JTN.0000000000000801","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nursing handoff of complete and accurate information is critical for patient safety yet is often difficult to achieve with consistency between nursing departments.</p><p><strong>Objective: </strong>This quality improvement project aims to describe the development and piloting of a standardized handoff tool for administration by computer tablet for nursing report.</p><p><strong>Methods: </strong>This descriptive quality improvement initiative was conducted in an 885-bed Level I trauma center in the Southeast Region of the United States. The study was completed in three phases. First, emergency department and trauma intensive care unit nurses were surveyed to determine handoff barriers and best practices. Second, the survey information was used to develop a standardized handoff tool incorporating tablet technology. Third, staff pilot testing was performed, followed by a final survey to ascertain staff feedback on the tool.</p><p><strong>Results: </strong>A total of n = 120 nurses completed the surveys, and pilot testing was conducted on n = 177 patient handoffs. Ninety-five percent of nurses expressed satisfaction with the tool and 65% with the tablet.</p><p><strong>Conclusion: </strong>This study supported using a standardized handoff tool between the emergency department and trauma intensive care unit and substantiated the benefits of using a tablet for face-to-face communication.</p>","PeriodicalId":0,"journal":{"name":"","volume":"31 4","pages":"218-223"},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a Standardized Nursing Handoff With Tablet Technology: A Quality Improvement Initiative.\",\"authors\":\"Briana R Miller, Kimberly A Maye, Frances D Charlton\",\"doi\":\"10.1097/JTN.0000000000000801\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Nursing handoff of complete and accurate information is critical for patient safety yet is often difficult to achieve with consistency between nursing departments.</p><p><strong>Objective: </strong>This quality improvement project aims to describe the development and piloting of a standardized handoff tool for administration by computer tablet for nursing report.</p><p><strong>Methods: </strong>This descriptive quality improvement initiative was conducted in an 885-bed Level I trauma center in the Southeast Region of the United States. The study was completed in three phases. First, emergency department and trauma intensive care unit nurses were surveyed to determine handoff barriers and best practices. Second, the survey information was used to develop a standardized handoff tool incorporating tablet technology. Third, staff pilot testing was performed, followed by a final survey to ascertain staff feedback on the tool.</p><p><strong>Results: </strong>A total of n = 120 nurses completed the surveys, and pilot testing was conducted on n = 177 patient handoffs. Ninety-five percent of nurses expressed satisfaction with the tool and 65% with the tablet.</p><p><strong>Conclusion: </strong>This study supported using a standardized handoff tool between the emergency department and trauma intensive care unit and substantiated the benefits of using a tablet for face-to-face communication.</p>\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":\"31 4\",\"pages\":\"218-223\"},\"PeriodicalIF\":0.0,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/JTN.0000000000000801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/JTN.0000000000000801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/4 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:完整准确的护理信息交接对患者安全至关重要,但护理部门之间往往难以实现信息交接的一致性:本质量改进项目旨在介绍标准化交接工具的开发和试用情况,该工具可通过电脑平板管理,用于护理报告:这项描述性质量改进项目在美国东南部地区一家拥有 885 张床位的一级创伤中心进行。研究分三个阶段完成。首先,对急诊科和创伤重症监护室的护士进行调查,以确定交接障碍和最佳实践。其次,利用调查信息开发了一种结合平板电脑技术的标准化交接工具。第三,对员工进行试点测试,然后进行最终调查,以确定员工对该工具的反馈意见:共有 n = 120 名护士完成了调查,并在 n = 177 次病人交接中进行了试点测试。95%的护士对该工具表示满意,65%的护士对平板电脑表示满意:这项研究支持在急诊科和创伤重症监护室之间使用标准化交接工具,并证实了使用平板电脑进行面对面交流的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
Development of a Standardized Nursing Handoff With Tablet Technology: A Quality Improvement Initiative.

Background: Nursing handoff of complete and accurate information is critical for patient safety yet is often difficult to achieve with consistency between nursing departments.

Objective: This quality improvement project aims to describe the development and piloting of a standardized handoff tool for administration by computer tablet for nursing report.

Methods: This descriptive quality improvement initiative was conducted in an 885-bed Level I trauma center in the Southeast Region of the United States. The study was completed in three phases. First, emergency department and trauma intensive care unit nurses were surveyed to determine handoff barriers and best practices. Second, the survey information was used to develop a standardized handoff tool incorporating tablet technology. Third, staff pilot testing was performed, followed by a final survey to ascertain staff feedback on the tool.

Results: A total of n = 120 nurses completed the surveys, and pilot testing was conducted on n = 177 patient handoffs. Ninety-five percent of nurses expressed satisfaction with the tool and 65% with the tablet.

Conclusion: This study supported using a standardized handoff tool between the emergency department and trauma intensive care unit and substantiated the benefits of using a tablet for face-to-face communication.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1