A. Karmakar, M. J. Khan, N. A. H. Shallik, A. H. M. N. Moustafa, Y. M. R. A. Toble, G. F. Strandvik
{"title":"正确的轨迹错误的位置:尽管气管导管的尖端位于气道外,但仍能显示正常的气管造影轨迹。","authors":"A. Karmakar, M. J. Khan, N. A. H. Shallik, A. H. M. N. Moustafa, Y. M. R. A. Toble, G. F. Strandvik","doi":"10.1002/anr3.12313","DOIUrl":null,"url":null,"abstract":"<p>Head and neck trauma can result in difficult airway management. A 25-year-old male required emergency tracheal intubation on arrival to the emergency department following a motorbike accident. Despite the presence of a normal capnography a computed tomography scan demonstrated a tracheal opening, an extra-tracheal position of the distal end of the tracheal tube, and extensive subcutaneous emphysema. The tube was re-directed into the trachea and the tracheal injury was surgically repaired. This case highlights that the presence of a normal capnograph does not necessarily mean that the distal end of the tracheal tube resides within the airway.</p>","PeriodicalId":72186,"journal":{"name":"Anaesthesia reports","volume":"12 2","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11237171/pdf/","citationCount":"0","resultStr":"{\"title\":\"Right trace wrong place: a normal capnography trace despite the tip of the tracheal tube existing outside the airway\",\"authors\":\"A. Karmakar, M. J. Khan, N. A. H. Shallik, A. H. M. N. Moustafa, Y. M. R. A. Toble, G. F. Strandvik\",\"doi\":\"10.1002/anr3.12313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Head and neck trauma can result in difficult airway management. A 25-year-old male required emergency tracheal intubation on arrival to the emergency department following a motorbike accident. Despite the presence of a normal capnography a computed tomography scan demonstrated a tracheal opening, an extra-tracheal position of the distal end of the tracheal tube, and extensive subcutaneous emphysema. The tube was re-directed into the trachea and the tracheal injury was surgically repaired. This case highlights that the presence of a normal capnograph does not necessarily mean that the distal end of the tracheal tube resides within the airway.</p>\",\"PeriodicalId\":72186,\"journal\":{\"name\":\"Anaesthesia reports\",\"volume\":\"12 2\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11237171/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesia reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/anr3.12313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia reports","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/anr3.12313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
Right trace wrong place: a normal capnography trace despite the tip of the tracheal tube existing outside the airway
Head and neck trauma can result in difficult airway management. A 25-year-old male required emergency tracheal intubation on arrival to the emergency department following a motorbike accident. Despite the presence of a normal capnography a computed tomography scan demonstrated a tracheal opening, an extra-tracheal position of the distal end of the tracheal tube, and extensive subcutaneous emphysema. The tube was re-directed into the trachea and the tracheal injury was surgically repaired. This case highlights that the presence of a normal capnograph does not necessarily mean that the distal end of the tracheal tube resides within the airway.