P. Yu. Mylnikov, A. V. Shchulkin, S. V. Seleznev, S. K. Pravkin, Yu. V. Abalenikhina, E. N. Yakusheva
{"title":"利用 HPLC-MS/MS 法开发和验证人血清中利辛普利、吲达帕胺、美托洛尔、缬沙坦和氨苯蝶啶的定量方法","authors":"P. Yu. Mylnikov, A. V. Shchulkin, S. V. Seleznev, S. K. Pravkin, Yu. V. Abalenikhina, E. N. Yakusheva","doi":"10.1007/s11094-024-03171-5","DOIUrl":null,"url":null,"abstract":"<p>A method for quantification of antihypertensive drugs (lisinopril, indapamide, metoprolol, valsartan, and amlodipine) in human blood serum was developed using high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). MeOH with added fexofenadine hydrochloride as an internal standard was used for sample preparation. The developed method was validated for the following parameters: selectivity, limit of quantitation, linearity, intra- and inter-run accuracy and precision, sample transfer, matrix effect, extraction effect, and sample stability. The analytical range of the method for all analytes was 1 – 1000 ng/mL, which made it possible to assess the patient adherence to treatment and conduct therapeutic drug monitoring.</p>","PeriodicalId":19990,"journal":{"name":"Pharmaceutical Chemistry Journal","volume":"39 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Validation of a Method for Quantification of Lisinopril, Indapamide, Metoprolol, Valsartan, and Amoldipine in Human Blood Serum by HPLC-MS/MS\",\"authors\":\"P. Yu. Mylnikov, A. V. Shchulkin, S. V. Seleznev, S. K. Pravkin, Yu. V. Abalenikhina, E. N. Yakusheva\",\"doi\":\"10.1007/s11094-024-03171-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A method for quantification of antihypertensive drugs (lisinopril, indapamide, metoprolol, valsartan, and amlodipine) in human blood serum was developed using high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). MeOH with added fexofenadine hydrochloride as an internal standard was used for sample preparation. The developed method was validated for the following parameters: selectivity, limit of quantitation, linearity, intra- and inter-run accuracy and precision, sample transfer, matrix effect, extraction effect, and sample stability. The analytical range of the method for all analytes was 1 – 1000 ng/mL, which made it possible to assess the patient adherence to treatment and conduct therapeutic drug monitoring.</p>\",\"PeriodicalId\":19990,\"journal\":{\"name\":\"Pharmaceutical Chemistry Journal\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutical Chemistry Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11094-024-03171-5\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MEDICINAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Chemistry Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11094-024-03171-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MEDICINAL","Score":null,"Total":0}
Development and Validation of a Method for Quantification of Lisinopril, Indapamide, Metoprolol, Valsartan, and Amoldipine in Human Blood Serum by HPLC-MS/MS
A method for quantification of antihypertensive drugs (lisinopril, indapamide, metoprolol, valsartan, and amlodipine) in human blood serum was developed using high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). MeOH with added fexofenadine hydrochloride as an internal standard was used for sample preparation. The developed method was validated for the following parameters: selectivity, limit of quantitation, linearity, intra- and inter-run accuracy and precision, sample transfer, matrix effect, extraction effect, and sample stability. The analytical range of the method for all analytes was 1 – 1000 ng/mL, which made it possible to assess the patient adherence to treatment and conduct therapeutic drug monitoring.
期刊介绍:
Pharmaceutical Chemistry Journal is a monthly publication devoted to scientific and technical research on the creation of new drugs and the improvement of manufacturing technology of drugs and intermediates. International contributors cover the entire spectrum of new drug research, including:
methods of synthesis;
results of pharmacological, toxicological, and biochemical studies;
investigation of structure - activity relationships in prediction of new compounds;
methods and technical facilities used; and
problems associated with the development of ecologically safe and economically feasible methods of industrial production.
In addition, analytical reviews of the international literature in the field provide coverage of the most recent developments around the world.
Pharmaceutical Chemistry Journal is a translation of the Russian journal Khimiko-Farmatsevticheskii Zhurnal. The Russian Volume Year is published in English from April.
All articles are peer-reviewed.