屈光需求对眼球偏差的影响:Zernike 系数重复性和变异性研究。

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY Current Eye Research Pub Date : 2024-12-01 Epub Date: 2024-07-14 DOI:10.1080/02713683.2024.2378009
María Mechó-García, María Arcas-Carbonell, Elvira Orduna-Hospital, Ana Sánchez-Cano, José Manuel González-Méijome
{"title":"屈光需求对眼球偏差的影响:Zernike 系数重复性和变异性研究。","authors":"María Mechó-García, María Arcas-Carbonell, Elvira Orduna-Hospital, Ana Sánchez-Cano, José Manuel González-Méijome","doi":"10.1080/02713683.2024.2378009","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the repeatability of the Zernike coefficients in healthy eyes when monocular accommodation was stimulated at different vergences demands.</p><p><strong>Methods: </strong>A total of 36 right eyes from healthy volunteers were prospectively and consecutively recruited for this study. Wavefront aberrometry was conducted to objectively characterize the ocular optical quality during accommodation, from the individual's far point to a 5 D accommodation demand in steps of 0.5 D. The repeatability of Zernike coefficients up to the fourth order was assessed by calculating the within-eye repeatability (<i>Sw</i>), the coefficient of repeatability (<i>CR</i>), the coefficient of variation (<i>CV</i>), and the intraclass correlation coefficient (<i>ICC</i>) as an indicator of measurement reliability.</p><p><strong>Results: </strong>Correlation among repeated measurements showed high reliability (ICC > 0.513) for all parameters measured except some fourth-order Zernike coefficients, C(4, -4) (ICC < 0.766), C(4, -2) (ICC < 0.875), C(4, 2) (ICC < 0.778) and C(4, 4) (ICC < 0.811). Greater repeatability and less variability were obtained for high-order Zernike coefficients (CR < 0.154), although an increase in CR in the coefficients analyzed was observed with increasing accommodative demand. No clear trend was evident in CV; however, it was observed that the low-order Zernike coefficients exhibit lower CV (CV < 1.93) compared to the high-order Zernike coefficients (CV > 0).</p><p><strong>Conclusions: </strong>The reliability of Zernike coefficients up to the fourth order in healthy young individuals demonstrated a strong consistency in measuring terms up to the fourth order, with more variability observed for high-order terms. The Zernike coefficients up to the third order exhibited the highest level of repeatability.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"1237-1246"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Influence of Accommodative Demand on Ocular Aberrations: A Study of Zernike Coefficients Repeatability and Variability.\",\"authors\":\"María Mechó-García, María Arcas-Carbonell, Elvira Orduna-Hospital, Ana Sánchez-Cano, José Manuel González-Méijome\",\"doi\":\"10.1080/02713683.2024.2378009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the repeatability of the Zernike coefficients in healthy eyes when monocular accommodation was stimulated at different vergences demands.</p><p><strong>Methods: </strong>A total of 36 right eyes from healthy volunteers were prospectively and consecutively recruited for this study. Wavefront aberrometry was conducted to objectively characterize the ocular optical quality during accommodation, from the individual's far point to a 5 D accommodation demand in steps of 0.5 D. The repeatability of Zernike coefficients up to the fourth order was assessed by calculating the within-eye repeatability (<i>Sw</i>), the coefficient of repeatability (<i>CR</i>), the coefficient of variation (<i>CV</i>), and the intraclass correlation coefficient (<i>ICC</i>) as an indicator of measurement reliability.</p><p><strong>Results: </strong>Correlation among repeated measurements showed high reliability (ICC > 0.513) for all parameters measured except some fourth-order Zernike coefficients, C(4, -4) (ICC < 0.766), C(4, -2) (ICC < 0.875), C(4, 2) (ICC < 0.778) and C(4, 4) (ICC < 0.811). Greater repeatability and less variability were obtained for high-order Zernike coefficients (CR < 0.154), although an increase in CR in the coefficients analyzed was observed with increasing accommodative demand. No clear trend was evident in CV; however, it was observed that the low-order Zernike coefficients exhibit lower CV (CV < 1.93) compared to the high-order Zernike coefficients (CV > 0).</p><p><strong>Conclusions: </strong>The reliability of Zernike coefficients up to the fourth order in healthy young individuals demonstrated a strong consistency in measuring terms up to the fourth order, with more variability observed for high-order terms. The Zernike coefficients up to the third order exhibited the highest level of repeatability.</p>\",\"PeriodicalId\":10782,\"journal\":{\"name\":\"Current Eye Research\",\"volume\":\" \",\"pages\":\"1237-1246\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Eye Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02713683.2024.2378009\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2024.2378009","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估健康眼睛在不同辐辏要求下刺激单眼调节时Zernike系数的可重复性:本研究前瞻性地连续招募了 36 名健康志愿者的右眼。通过计算眼内重复性(Sw)、重复性系数(CR)、变异系数(CV)和作为测量可靠性指标的类内相关系数(ICC),评估了Zernike系数四阶以下的重复性:除了一些四阶 Zernike 系数:C(4, -4)(ICC < 0.766)、C(4, -2)(ICC < 0.875)、C(4, 2)(ICC < 0.778)和 C(4,4)(ICC < 0.811)外,重复测量之间的相关性显示所有测量参数的可靠性都很高(ICC > 0.513)。高阶 Zernike 系数的重复性更高,变异性更小(CR < 0.154),但随着适应需求的增加,所分析系数的 CR 也在增加。CV方面没有明显的趋势;不过,与高阶泽尔内克系数(CV > 0)相比,低阶泽尔内克系数的CV较低(CV < 1.93):健康年轻人四阶以下 Zernike 系数的可靠性表明,四阶以下项的测量具有很强的一致性,而高阶项的测量变异性更大。三阶以下的泽尼克系数具有最高的重复性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Influence of Accommodative Demand on Ocular Aberrations: A Study of Zernike Coefficients Repeatability and Variability.

Purpose: To evaluate the repeatability of the Zernike coefficients in healthy eyes when monocular accommodation was stimulated at different vergences demands.

Methods: A total of 36 right eyes from healthy volunteers were prospectively and consecutively recruited for this study. Wavefront aberrometry was conducted to objectively characterize the ocular optical quality during accommodation, from the individual's far point to a 5 D accommodation demand in steps of 0.5 D. The repeatability of Zernike coefficients up to the fourth order was assessed by calculating the within-eye repeatability (Sw), the coefficient of repeatability (CR), the coefficient of variation (CV), and the intraclass correlation coefficient (ICC) as an indicator of measurement reliability.

Results: Correlation among repeated measurements showed high reliability (ICC > 0.513) for all parameters measured except some fourth-order Zernike coefficients, C(4, -4) (ICC < 0.766), C(4, -2) (ICC < 0.875), C(4, 2) (ICC < 0.778) and C(4, 4) (ICC < 0.811). Greater repeatability and less variability were obtained for high-order Zernike coefficients (CR < 0.154), although an increase in CR in the coefficients analyzed was observed with increasing accommodative demand. No clear trend was evident in CV; however, it was observed that the low-order Zernike coefficients exhibit lower CV (CV < 1.93) compared to the high-order Zernike coefficients (CV > 0).

Conclusions: The reliability of Zernike coefficients up to the fourth order in healthy young individuals demonstrated a strong consistency in measuring terms up to the fourth order, with more variability observed for high-order terms. The Zernike coefficients up to the third order exhibited the highest level of repeatability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Eye Research
Current Eye Research 医学-眼科学
CiteScore
4.60
自引率
0.00%
发文量
163
审稿时长
12 months
期刊介绍: The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.
期刊最新文献
Relationship of Angle Kappa with Ocular Parameters using Swept-Source Ocular Coherence Tomography in Cataract Surgery Patients. Selective Gamma-Secretase Inhibition by CHF5074 Attenuates Inflammation and Neovascularization in a Murine Model of Choroidal Neovascularization. Expression of PAX6 and Keratocyte-Characteristic Markers in Human Limbal Stromal Cells of Congenital Aniridia and Healthy Subjects, In Vitro. Brolucizumab and Platelet Activation and Reactivity. Correction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1