使用全自动系统对重组蛋白进行快速糖定量评估

IF 1.2 4区 综合性期刊 Q3 MULTIDISCIPLINARY SCIENCES Jove-Journal of Visualized Experiments Pub Date : 2024-06-28 DOI:10.3791/66571
Sayaka Fuseya, Ayaka Ono, Hiromi Ootani, Saho Mizukado, Tomomi Obayashi, Nana Tanaka, Hiroko Shimazaki, Kenji Kajiyama, Moe Ashitomi, Shiori Yasuda, Takenori Miyabe, Kazuhiro Nakamura, Osamu Segawa, Kazumi Sawakami, Atsushi Kuno
{"title":"使用全自动系统对重组蛋白进行快速糖定量评估","authors":"Sayaka Fuseya, Ayaka Ono, Hiromi Ootani, Saho Mizukado, Tomomi Obayashi, Nana Tanaka, Hiroko Shimazaki, Kenji Kajiyama, Moe Ashitomi, Shiori Yasuda, Takenori Miyabe, Kazuhiro Nakamura, Osamu Segawa, Kazumi Sawakami, Atsushi Kuno","doi":"10.3791/66571","DOIUrl":null,"url":null,"abstract":"<p><p>Protein glycosylation, a critical post-translational modification, influences the stability, efficacy, and immunogenicity of recombinant proteins, including biopharmaceuticals. Glycan structures exhibit significant heterogeneity, varying with production cell types, culture conditions, and purification methods. Consequently, monitoring and evaluating the glycan structures of recombinant proteins is vital, particularly in biopharmaceutical production. The lectin microarray, a technique complementary to mass spectrometry, boasts high sensitivity and ease of use. However, it typically requires more than a day to yield results. To adapt it to non-glycoscience research or drug product process development, an automated, high-throughput alternative is needed. Therefore, the world's first fully automated lectin-based glycan profiling system was developed, utilizing the \"bead array in a single tip (BIST)\" technology concept. This system allows for the preparation and storage of lectin-immobilized beads in units of 1,000, with customizable parallel insertion orders for various purposes. This article presents a practical protocol for research involving \"glyco-qualified\" recombinant proteins. After testing their reactivity against 12 polyacrylamide-glycan conjugates, 15 lectins were selected to increase the system's versatility. In addition, the sample labeling process was optimized by switching from Cy3 to biotin, reducing the overall processing time by 30 min. For immediate data qualification, lectin-binding signals are displayed as a dotcode on the top monitor. The system's reliability was confirmed through day-to-day reproducibility tests, repeatability tests, and long-term storage tests, with a coefficient of variation of <10%. This user-friendly and rapid glyco-analyzer has potential applications in the quality monitoring of endogenous glycoproteins for biomarker evaluation and validation. This method facilitates analysis for those new to glycoscience, thereby broadening its practical utility.</p>","PeriodicalId":48787,"journal":{"name":"Jove-Journal of Visualized Experiments","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid Glyco-Qualitative Assessment of Recombinant Proteins Using a Fully Automated System.\",\"authors\":\"Sayaka Fuseya, Ayaka Ono, Hiromi Ootani, Saho Mizukado, Tomomi Obayashi, Nana Tanaka, Hiroko Shimazaki, Kenji Kajiyama, Moe Ashitomi, Shiori Yasuda, Takenori Miyabe, Kazuhiro Nakamura, Osamu Segawa, Kazumi Sawakami, Atsushi Kuno\",\"doi\":\"10.3791/66571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Protein glycosylation, a critical post-translational modification, influences the stability, efficacy, and immunogenicity of recombinant proteins, including biopharmaceuticals. Glycan structures exhibit significant heterogeneity, varying with production cell types, culture conditions, and purification methods. Consequently, monitoring and evaluating the glycan structures of recombinant proteins is vital, particularly in biopharmaceutical production. The lectin microarray, a technique complementary to mass spectrometry, boasts high sensitivity and ease of use. However, it typically requires more than a day to yield results. To adapt it to non-glycoscience research or drug product process development, an automated, high-throughput alternative is needed. Therefore, the world's first fully automated lectin-based glycan profiling system was developed, utilizing the \\\"bead array in a single tip (BIST)\\\" technology concept. This system allows for the preparation and storage of lectin-immobilized beads in units of 1,000, with customizable parallel insertion orders for various purposes. This article presents a practical protocol for research involving \\\"glyco-qualified\\\" recombinant proteins. After testing their reactivity against 12 polyacrylamide-glycan conjugates, 15 lectins were selected to increase the system's versatility. In addition, the sample labeling process was optimized by switching from Cy3 to biotin, reducing the overall processing time by 30 min. For immediate data qualification, lectin-binding signals are displayed as a dotcode on the top monitor. The system's reliability was confirmed through day-to-day reproducibility tests, repeatability tests, and long-term storage tests, with a coefficient of variation of <10%. This user-friendly and rapid glyco-analyzer has potential applications in the quality monitoring of endogenous glycoproteins for biomarker evaluation and validation. This method facilitates analysis for those new to glycoscience, thereby broadening its practical utility.</p>\",\"PeriodicalId\":48787,\"journal\":{\"name\":\"Jove-Journal of Visualized Experiments\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jove-Journal of Visualized Experiments\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3791/66571\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jove-Journal of Visualized Experiments","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3791/66571","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

蛋白质糖基化是一种关键的翻译后修饰,影响着包括生物制药在内的重组蛋白质的稳定性、功效和免疫原性。糖基化结构表现出明显的异质性,随生产细胞类型、培养条件和纯化方法的不同而变化。因此,监测和评估重组蛋白的糖分子结构至关重要,尤其是在生物制药生产中。凝集素微阵列是质谱法的补充技术,具有灵敏度高、使用方便等优点。然而,它通常需要一天以上的时间才能得出结果。为使其适用于非糖科学研究或药物产品工艺开发,需要一种自动化、高通量的替代方法。因此,利用 "单头微珠阵列(BIST)"技术概念,开发出了世界上首个基于凝集素的全自动聚糖分析系统。该系统可制备和储存以 1,000 为单位的凝集素固定珠,并可根据不同目的定制平行插入顺序。本文介绍了涉及 "糖限定 "重组蛋白研究的实用方案。在测试了它们对 12 种聚丙烯酰胺-聚糖共轭物的反应性后,选择了 15 种凝集素来提高系统的通用性。此外,还优化了样品标记过程,将 Cy3 改为生物素,使整个处理时间缩短了 30 分钟。为了即时鉴定数据,凝集素结合信号会以点码形式显示在顶部显示器上。该系统的可靠性已通过日常重现性测试、重复性测试和长期储存测试得到证实,其变异系数为
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rapid Glyco-Qualitative Assessment of Recombinant Proteins Using a Fully Automated System.

Protein glycosylation, a critical post-translational modification, influences the stability, efficacy, and immunogenicity of recombinant proteins, including biopharmaceuticals. Glycan structures exhibit significant heterogeneity, varying with production cell types, culture conditions, and purification methods. Consequently, monitoring and evaluating the glycan structures of recombinant proteins is vital, particularly in biopharmaceutical production. The lectin microarray, a technique complementary to mass spectrometry, boasts high sensitivity and ease of use. However, it typically requires more than a day to yield results. To adapt it to non-glycoscience research or drug product process development, an automated, high-throughput alternative is needed. Therefore, the world's first fully automated lectin-based glycan profiling system was developed, utilizing the "bead array in a single tip (BIST)" technology concept. This system allows for the preparation and storage of lectin-immobilized beads in units of 1,000, with customizable parallel insertion orders for various purposes. This article presents a practical protocol for research involving "glyco-qualified" recombinant proteins. After testing their reactivity against 12 polyacrylamide-glycan conjugates, 15 lectins were selected to increase the system's versatility. In addition, the sample labeling process was optimized by switching from Cy3 to biotin, reducing the overall processing time by 30 min. For immediate data qualification, lectin-binding signals are displayed as a dotcode on the top monitor. The system's reliability was confirmed through day-to-day reproducibility tests, repeatability tests, and long-term storage tests, with a coefficient of variation of <10%. This user-friendly and rapid glyco-analyzer has potential applications in the quality monitoring of endogenous glycoproteins for biomarker evaluation and validation. This method facilitates analysis for those new to glycoscience, thereby broadening its practical utility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Jove-Journal of Visualized Experiments
Jove-Journal of Visualized Experiments MULTIDISCIPLINARY SCIENCES-
CiteScore
2.10
自引率
0.00%
发文量
992
期刊介绍: JoVE, the Journal of Visualized Experiments, is the world''s first peer reviewed scientific video journal. Established in 2006, JoVE is devoted to publishing scientific research in a visual format to help researchers overcome two of the biggest challenges facing the scientific research community today; poor reproducibility and the time and labor intensive nature of learning new experimental techniques.
期刊最新文献
A Rapid Method to Confine and Safely Handle Bees in the Field. Characterizing Mediated Extracellular Electron Transfer in Lactic Acid Bacteria with a Three-Electrode, Two-Chamber Bioelectrochemical System. Consistent Delivery of Adeno-Associated Virus via Lateral Tail-Vein Injection in Adult Mice. Detection of DNA Breaks in Dividing Human Cells by Neutral Comet Assay. Effective Detection of Hoechst Side Population Cells by Flow Cytometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1