{"title":"白内障和微创青光眼联合手术后的屈光效果。","authors":"Abdulla Shaheen MD ,&nbsp;Gabriele Gallo Afflitto MD ,&nbsp;Swarup S. Swaminathan MD","doi":"10.1016/j.ogla.2024.07.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To compare refractive outcomes in eyes undergoing cataract extraction (CE) alone, CE with goniotomy (CE/goniotomy), and CE with Schlemm’s canal stent (CE/SCS) insertion.</div></div><div><h3>Design</h3><div>Retrospective cohort study.</div></div><div><h3>Participants</h3><div>Eyes from the Bascom Palmer Glaucoma Repository undergoing CE/goniotomy, CE/SCS insertion, or uncomplicated CE alone between July 2014 and February 2022 were identified.</div></div><div><h3>Methods</h3><div>Refraction data were analyzed at postoperative month (POM) 1 and 6 with Kruskal–Wallis and Dunn’s tests. Anisometropia was defined as a spherical equivalent (SE) difference of ≥2D.</div></div><div><h3>Main Outcome Measures</h3><div>The primary outcome was mean refraction at POM1 and POM6 across the 3 surgical groups. Secondary outcomes were comparisons of refraction and visual acuity (VA) among different goniotomy and Schlemm’s canal stent (SCS) devices, as well as incidence of anisometropia.</div></div><div><h3>Results</h3><div>A total of 8360 eyes (150 CE/goniotomy, 395 CE/SCS, and 7815 CE alone) from 6059 patients were analyzed. At POM1, mean SE in the CE/goniotomy, CE/SCS, and CE alone groups was −0.36 ± 0.91D, −0.31 ± 0.85D, and −0.39 ± 0.88D respectively (<em>P</em> = 0.019). Mean logarithm of the minimum angle of resolution VA was 0.10 ± 0.20, 0.08 ± 0.19, and 0.14 ± 0.26 respectively (<em>P</em> = 0.002, CE/SCS vs. CE alone). No statistically significant differences were noted at POM6. Anisometropia occurred at POM1 in 2 patients (13.3%) in the CE/goniotomy-CE group, 1 patient (3.2%) in the CE/SCS-CE group, and 184 patients (4.9%) in the CE-CE group (<em>P</em> = 0.217). At POM6, mean SEs were −0.38 ± 0.97D (CE/goniotomy), −0.35 ± 0.81D (CE/SCS), and −0.40 ± 0.91D (CE alone; <em>P</em> = 0.473). No significant differences in overall refractive outcomes were observed with different SCS or goniotomy devices. Among primary open-angle glaucoma/normal-tension glaucoma eyes, mean SE at POM1 was −0.36 ± 0.73D (CE/goniotomy), −0.24 ± 0.84D (CE/SCS), and −0.45 ± 0.81D (CE alone; <em>P</em> &lt; 0.001).</div></div><div><h3>Conclusions</h3><div>Concurrent SCS insertion or goniotomy with CE was associated with some statistically significant differences in postoperative refraction and VA, although these small magnitude differences were unlikely to be clinically meaningful.</div></div><div><h3>Financial Disclosure(s)</h3><div>Proprietary or commercial disclosure may be found after the references in the Footnotes and Disclosures at the end of this article.</div></div>","PeriodicalId":19519,"journal":{"name":"Ophthalmology. Glaucoma","volume":"7 6","pages":"Pages 608-614"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Refractive Outcomes Following Combined Cataract and Microinvasive Glaucoma Surgery\",\"authors\":\"Abdulla Shaheen MD ,&nbsp;Gabriele Gallo Afflitto MD ,&nbsp;Swarup S. Swaminathan MD\",\"doi\":\"10.1016/j.ogla.2024.07.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><div>To compare refractive outcomes in eyes undergoing cataract extraction (CE) alone, CE with goniotomy (CE/goniotomy), and CE with Schlemm’s canal stent (CE/SCS) insertion.</div></div><div><h3>Design</h3><div>Retrospective cohort study.</div></div><div><h3>Participants</h3><div>Eyes from the Bascom Palmer Glaucoma Repository undergoing CE/goniotomy, CE/SCS insertion, or uncomplicated CE alone between July 2014 and February 2022 were identified.</div></div><div><h3>Methods</h3><div>Refraction data were analyzed at postoperative month (POM) 1 and 6 with Kruskal–Wallis and Dunn’s tests. Anisometropia was defined as a spherical equivalent (SE) difference of ≥2D.</div></div><div><h3>Main Outcome Measures</h3><div>The primary outcome was mean refraction at POM1 and POM6 across the 3 surgical groups. Secondary outcomes were comparisons of refraction and visual acuity (VA) among different goniotomy and Schlemm’s canal stent (SCS) devices, as well as incidence of anisometropia.</div></div><div><h3>Results</h3><div>A total of 8360 eyes (150 CE/goniotomy, 395 CE/SCS, and 7815 CE alone) from 6059 patients were analyzed. At POM1, mean SE in the CE/goniotomy, CE/SCS, and CE alone groups was −0.36 ± 0.91D, −0.31 ± 0.85D, and −0.39 ± 0.88D respectively (<em>P</em> = 0.019). Mean logarithm of the minimum angle of resolution VA was 0.10 ± 0.20, 0.08 ± 0.19, and 0.14 ± 0.26 respectively (<em>P</em> = 0.002, CE/SCS vs. CE alone). No statistically significant differences were noted at POM6. Anisometropia occurred at POM1 in 2 patients (13.3%) in the CE/goniotomy-CE group, 1 patient (3.2%) in the CE/SCS-CE group, and 184 patients (4.9%) in the CE-CE group (<em>P</em> = 0.217). At POM6, mean SEs were −0.38 ± 0.97D (CE/goniotomy), −0.35 ± 0.81D (CE/SCS), and −0.40 ± 0.91D (CE alone; <em>P</em> = 0.473). No significant differences in overall refractive outcomes were observed with different SCS or goniotomy devices. Among primary open-angle glaucoma/normal-tension glaucoma eyes, mean SE at POM1 was −0.36 ± 0.73D (CE/goniotomy), −0.24 ± 0.84D (CE/SCS), and −0.45 ± 0.81D (CE alone; <em>P</em> &lt; 0.001).</div></div><div><h3>Conclusions</h3><div>Concurrent SCS insertion or goniotomy with CE was associated with some statistically significant differences in postoperative refraction and VA, although these small magnitude differences were unlikely to be clinically meaningful.</div></div><div><h3>Financial Disclosure(s)</h3><div>Proprietary or commercial disclosure may be found after the references in the Footnotes and Disclosures at the end of this article.</div></div>\",\"PeriodicalId\":19519,\"journal\":{\"name\":\"Ophthalmology. Glaucoma\",\"volume\":\"7 6\",\"pages\":\"Pages 608-614\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmology. Glaucoma\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2589419624001339\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology. Glaucoma","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589419624001339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较单纯白内障摘除术(CE)、CE联合眼球切开术(CE/goniotomy)和CE联合Schlemm's管支架植入术(CE/SCS)的屈光结果:设计:回顾性队列研究:从巴斯科姆-帕尔默青光眼资料库中找出2014年7月至2022年2月期间接受CE/开颅手术、CE/SCS植入术或单纯无并发症CE手术的眼球:采用Kruskal-Wallis和Dunn检验分析术后第1个月和第6个月的屈光数据。主要结果指标:主要结果是三个手术组 POM1 和 POM6 时的平均屈光度。次要结果是比较不同眼球切开术和 SCS 设备的屈光度和视力以及斜视发生率:共分析了来自 6059 名患者的 8360 只眼睛(150 只 CE/眼球切开术、395 只 CE/SCS 和 7815 只 CE)。POM1时,CE/开颅手术组、CE/SCS组和单纯CE组的平均SE分别为-0.36±0.91D、-0.31±0.85D和-0.39±0.88D(P=0.019)。平均 logMAR VA 分别为 0.10±0.20、0.08±0.19 和 0.14±0.26(P=0.002,CE/SCS vs. 单用 CE)。在 POM6 时,差异无统计学意义。在POM1时,CE/眼球切开术-CE组有2名患者(13.3%)出现斜视,CE/SCS-CE组有1名患者(3.2%)出现斜视,CE-CE组有184名患者(4.9%)出现斜视(P=0.217)。POM6时,平均SE为-0.38±0.97D(CE/角膜切开术)、-0.35±0.81D(CE/SCS)和-0.40±0.91D(单用CE;P=0.473)。不同的 SCS 或眼球切开术设备在总体屈光结果上没有明显差异。在原发性开角型青光眼(POAG)/正常张力青光眼(NTG)眼中,POM1时的平均SE为-0.36±0.73D(CE/眼压切开术)、-0.24±0.84D(CE/SCS)和-0.45±0.81D(仅CE;p结论:同时插入 SCS 或进行神经节切开术与 CE 在术后屈光度和视力方面存在一些统计学意义上的显著差异,尽管这些微小的差异不太可能具有临床意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Refractive Outcomes Following Combined Cataract and Microinvasive Glaucoma Surgery

Purpose

To compare refractive outcomes in eyes undergoing cataract extraction (CE) alone, CE with goniotomy (CE/goniotomy), and CE with Schlemm’s canal stent (CE/SCS) insertion.

Design

Retrospective cohort study.

Participants

Eyes from the Bascom Palmer Glaucoma Repository undergoing CE/goniotomy, CE/SCS insertion, or uncomplicated CE alone between July 2014 and February 2022 were identified.

Methods

Refraction data were analyzed at postoperative month (POM) 1 and 6 with Kruskal–Wallis and Dunn’s tests. Anisometropia was defined as a spherical equivalent (SE) difference of ≥2D.

Main Outcome Measures

The primary outcome was mean refraction at POM1 and POM6 across the 3 surgical groups. Secondary outcomes were comparisons of refraction and visual acuity (VA) among different goniotomy and Schlemm’s canal stent (SCS) devices, as well as incidence of anisometropia.

Results

A total of 8360 eyes (150 CE/goniotomy, 395 CE/SCS, and 7815 CE alone) from 6059 patients were analyzed. At POM1, mean SE in the CE/goniotomy, CE/SCS, and CE alone groups was −0.36 ± 0.91D, −0.31 ± 0.85D, and −0.39 ± 0.88D respectively (P = 0.019). Mean logarithm of the minimum angle of resolution VA was 0.10 ± 0.20, 0.08 ± 0.19, and 0.14 ± 0.26 respectively (P = 0.002, CE/SCS vs. CE alone). No statistically significant differences were noted at POM6. Anisometropia occurred at POM1 in 2 patients (13.3%) in the CE/goniotomy-CE group, 1 patient (3.2%) in the CE/SCS-CE group, and 184 patients (4.9%) in the CE-CE group (P = 0.217). At POM6, mean SEs were −0.38 ± 0.97D (CE/goniotomy), −0.35 ± 0.81D (CE/SCS), and −0.40 ± 0.91D (CE alone; P = 0.473). No significant differences in overall refractive outcomes were observed with different SCS or goniotomy devices. Among primary open-angle glaucoma/normal-tension glaucoma eyes, mean SE at POM1 was −0.36 ± 0.73D (CE/goniotomy), −0.24 ± 0.84D (CE/SCS), and −0.45 ± 0.81D (CE alone; P < 0.001).

Conclusions

Concurrent SCS insertion or goniotomy with CE was associated with some statistically significant differences in postoperative refraction and VA, although these small magnitude differences were unlikely to be clinically meaningful.

Financial Disclosure(s)

Proprietary or commercial disclosure may be found after the references in the Footnotes and Disclosures at the end of this article.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ophthalmology. Glaucoma
Ophthalmology. Glaucoma OPHTHALMOLOGY-
CiteScore
4.80
自引率
6.90%
发文量
140
审稿时长
46 days
期刊最新文献
Reply Editorial Board Contents Posterior Capsular Pigment Deposition in a Case of Pigmentary Glaucoma Iridoschisis: The Shredded Iris
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1