推进腰椎手术中的机器人引导技术:系统回顾和荟萃分析。

Expert review of medical devices Pub Date : 2024-08-01 Epub Date: 2024-07-15 DOI:10.1080/17434440.2024.2378080
Temitope Emmanuel Komolafe, Liang Zhou, Wenlong Zhao, Jiachen Guo, Zongdao Li, Zhiping Fan, Blessing Funmi Komolafe, Wang Wei, Oluwarotimi Williams Samuel
{"title":"推进腰椎手术中的机器人引导技术:系统回顾和荟萃分析。","authors":"Temitope Emmanuel Komolafe, Liang Zhou, Wenlong Zhao, Jiachen Guo, Zongdao Li, Zhiping Fan, Blessing Funmi Komolafe, Wang Wei, Oluwarotimi Williams Samuel","doi":"10.1080/17434440.2024.2378080","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Lumbar spine surgery is a crucial intervention for addressing spinal injuries or conditions affecting the spine, often involving lumbar fusion through pedicle screw (PS) insertion. The precision of PS placement is pivotal in orthopedic surgery. This systematic review compares the accuracy of robot-guided (RG) surgery with free-hand fluoroscopy-guided (FFG), free-hand without fluoroscopy-guided (FHG), and computed tomography image-guided (CTG) techniques for PS insertion.</p><p><strong>Methods: </strong>A systematic search of various databases from 1 January 2013 to 30 December 2023 was conducted following PRISMA guidelines. Primary outcomes, including PS insertion accuracy and breach rate, were analyzed using a random-effects model. Risk of bias was assessed using the Newcastle-Ottawa Scale.</p><p><strong>Results: </strong>The overall accuracy of PS insertion using RG, based on 37 studies involving 3,837 patients and 22,117 PS, is 97.9%, with a breach rate of 0.021. RG demonstrated superior accuracy compared to FHG and CTG, with breach rates of 3.4 and 0.015 respectively for RG versus FHG, and 3.8 and 0.026 for RG versus CTG. Additionally, RG was associated with reduced mean estimated blood loss compared to CTG, indicating improved safety.</p><p><strong>Conclusions: </strong>The RG is associated with enhanced accuracy of PS insertion and reduced breach rates over other methods. However, additional randomized controlled trials comparing these modalities are needed for further validation.</p><p><strong>Prospero registration: </strong>CRD42023483997.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advancing robot-guided techniques in lumbar spine surgery: a systematic review and meta-analysis.\",\"authors\":\"Temitope Emmanuel Komolafe, Liang Zhou, Wenlong Zhao, Jiachen Guo, Zongdao Li, Zhiping Fan, Blessing Funmi Komolafe, Wang Wei, Oluwarotimi Williams Samuel\",\"doi\":\"10.1080/17434440.2024.2378080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Lumbar spine surgery is a crucial intervention for addressing spinal injuries or conditions affecting the spine, often involving lumbar fusion through pedicle screw (PS) insertion. The precision of PS placement is pivotal in orthopedic surgery. This systematic review compares the accuracy of robot-guided (RG) surgery with free-hand fluoroscopy-guided (FFG), free-hand without fluoroscopy-guided (FHG), and computed tomography image-guided (CTG) techniques for PS insertion.</p><p><strong>Methods: </strong>A systematic search of various databases from 1 January 2013 to 30 December 2023 was conducted following PRISMA guidelines. Primary outcomes, including PS insertion accuracy and breach rate, were analyzed using a random-effects model. Risk of bias was assessed using the Newcastle-Ottawa Scale.</p><p><strong>Results: </strong>The overall accuracy of PS insertion using RG, based on 37 studies involving 3,837 patients and 22,117 PS, is 97.9%, with a breach rate of 0.021. RG demonstrated superior accuracy compared to FHG and CTG, with breach rates of 3.4 and 0.015 respectively for RG versus FHG, and 3.8 and 0.026 for RG versus CTG. Additionally, RG was associated with reduced mean estimated blood loss compared to CTG, indicating improved safety.</p><p><strong>Conclusions: </strong>The RG is associated with enhanced accuracy of PS insertion and reduced breach rates over other methods. However, additional randomized controlled trials comparing these modalities are needed for further validation.</p><p><strong>Prospero registration: </strong>CRD42023483997.</p>\",\"PeriodicalId\":94006,\"journal\":{\"name\":\"Expert review of medical devices\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert review of medical devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2024.2378080\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2024.2378080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:腰椎手术是治疗脊柱损伤或影响脊柱的疾病的重要干预措施,通常涉及通过椎弓根螺钉(PS)插入进行腰椎融合。椎弓根螺钉置入的精确度在骨科手术中至关重要。本系统性综述比较了机器人引导(RG)手术与徒手透视引导(FFG)、徒手无透视引导(FHG)和计算机断层扫描图像引导(CTG)技术植入 PS 的准确性:按照 PRISMA 指南对 2013 年 1 月 1 日至 2023 年 12 月 30 日的各种数据库进行了系统检索。采用随机效应模型分析了主要结果,包括PS插入的准确性和破损率。采用纽卡斯尔-渥太华量表评估偏倚风险:根据涉及 3,837 名患者和 22,117 个 PS 的 37 项研究,使用 RG 插入 PS 的总体准确率为 97.9%,破损率为 0.021。与 FHG 和 CTG 相比,RG 显示出更高的准确性,RG 与 FHG 相比,破损率分别为 3.4 和 0.015,RG 与 CTG 相比,破损率分别为 3.8 和 0.026。此外,与 CTG 相比,RG 可降低平均估计失血量,从而提高安全性:结论:与其他方法相比,RG 可提高 PS 插入的准确性并降低破损率。结论:与其他方法相比,RG 可提高 PS 插入的准确性并降低破损率,但还需要更多的随机对照试验对这些方法进行比较,以进一步验证其有效性:CRD42023483997。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Advancing robot-guided techniques in lumbar spine surgery: a systematic review and meta-analysis.

Background: Lumbar spine surgery is a crucial intervention for addressing spinal injuries or conditions affecting the spine, often involving lumbar fusion through pedicle screw (PS) insertion. The precision of PS placement is pivotal in orthopedic surgery. This systematic review compares the accuracy of robot-guided (RG) surgery with free-hand fluoroscopy-guided (FFG), free-hand without fluoroscopy-guided (FHG), and computed tomography image-guided (CTG) techniques for PS insertion.

Methods: A systematic search of various databases from 1 January 2013 to 30 December 2023 was conducted following PRISMA guidelines. Primary outcomes, including PS insertion accuracy and breach rate, were analyzed using a random-effects model. Risk of bias was assessed using the Newcastle-Ottawa Scale.

Results: The overall accuracy of PS insertion using RG, based on 37 studies involving 3,837 patients and 22,117 PS, is 97.9%, with a breach rate of 0.021. RG demonstrated superior accuracy compared to FHG and CTG, with breach rates of 3.4 and 0.015 respectively for RG versus FHG, and 3.8 and 0.026 for RG versus CTG. Additionally, RG was associated with reduced mean estimated blood loss compared to CTG, indicating improved safety.

Conclusions: The RG is associated with enhanced accuracy of PS insertion and reduced breach rates over other methods. However, additional randomized controlled trials comparing these modalities are needed for further validation.

Prospero registration: CRD42023483997.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Orphan and paediatric medical devices in Europe: recommendations to support their availability for on-label and off-label clinical indications. Medical device similarity analysis: a promising approach to medical device equivalence regulation. Delivery systems for transcatheter therapies of congenital heart disease. Evaluation and management of coronary artery disease in transcatheter aortic valve implantation candidates with severe aortic stenosis and coronary artery disease: technology and techniques. Transforming medical education: the impact of innovations in technology and medical devices.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1