{"title":"[心外起搏器感染通过再梗阻切除术拔除导线治疗:一例病例报告]。","authors":"Akira Hashino, Hiroshi Kumano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A 69-year-old woman was diagnosed with a pacemaker infection after generator-exchange. Eight years ago, she underwent mitral and tricuspid valve replacement and had biventricular pacing with three pairs of epicardial leads placed in the right atrium, right ventricle, and left ventricle for left ventricular dysfunction. Skin perforation due to infection was detected 1 month after generator-exchange. At first, antibiotic treatment, generator-re-exchange, and pocket repositioning surgery were performed. Following all these failed attempts, a temporary pacemaker was placed, the infected generator was removed, and the lead was cut short. Eight days later, new intravenous caradiac resynchronization therapy pacemaker (CRT-P) implantation was performed. However, despite the repeat debridement, infection at the lead stumps recurred. Moreover, plain chest computed tomography (CT) revealed an abscess around the leads in the anterior mediastinum. Eventually, leads were removed under extracorporeal circulation via re-sternotomy. Postoperative course was uneventful, and she has been doing well without recurrence of infection for 6 years after operation.</p>","PeriodicalId":17841,"journal":{"name":"Kyobu geka. The Japanese journal of thoracic surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Epicardial Pacemaker Infection Treated by Leads Removal via Re-sternotomy:Report of a Case].\",\"authors\":\"Akira Hashino, Hiroshi Kumano\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A 69-year-old woman was diagnosed with a pacemaker infection after generator-exchange. Eight years ago, she underwent mitral and tricuspid valve replacement and had biventricular pacing with three pairs of epicardial leads placed in the right atrium, right ventricle, and left ventricle for left ventricular dysfunction. Skin perforation due to infection was detected 1 month after generator-exchange. At first, antibiotic treatment, generator-re-exchange, and pocket repositioning surgery were performed. Following all these failed attempts, a temporary pacemaker was placed, the infected generator was removed, and the lead was cut short. Eight days later, new intravenous caradiac resynchronization therapy pacemaker (CRT-P) implantation was performed. However, despite the repeat debridement, infection at the lead stumps recurred. Moreover, plain chest computed tomography (CT) revealed an abscess around the leads in the anterior mediastinum. Eventually, leads were removed under extracorporeal circulation via re-sternotomy. Postoperative course was uneventful, and she has been doing well without recurrence of infection for 6 years after operation.</p>\",\"PeriodicalId\":17841,\"journal\":{\"name\":\"Kyobu geka. The Japanese journal of thoracic surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kyobu geka. The Japanese journal of thoracic surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kyobu geka. The Japanese journal of thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

一名 69 岁的妇女在更换发电机后被诊断出起搏器感染。八年前,她接受了二尖瓣和三尖瓣置换术,并因左心室功能障碍在右心房、右心室和左心室放置了三对心外膜导联进行双心室起搏。更换发电机 1 个月后,发现因感染导致皮肤穿孔。起初,医生采取了抗生素治疗、重新更换发生器和口袋复位手术。在所有这些尝试失败后,患者被安置了一个临时起搏器,被感染的发生器被移除,导联被剪短。八天后,又进行了新的静脉注射心脏再同步治疗起搏器(CRT-P)植入手术。然而,尽管再次进行了清创,但导联线残端仍再次发生感染。此外,胸部计算机断层扫描(CT)显示前纵隔的导联周围有脓肿。最终,在体外循环下通过再切口取出了导联。术后病程顺利,术后 6 年来情况良好,未再发生感染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Epicardial Pacemaker Infection Treated by Leads Removal via Re-sternotomy:Report of a Case].

A 69-year-old woman was diagnosed with a pacemaker infection after generator-exchange. Eight years ago, she underwent mitral and tricuspid valve replacement and had biventricular pacing with three pairs of epicardial leads placed in the right atrium, right ventricle, and left ventricle for left ventricular dysfunction. Skin perforation due to infection was detected 1 month after generator-exchange. At first, antibiotic treatment, generator-re-exchange, and pocket repositioning surgery were performed. Following all these failed attempts, a temporary pacemaker was placed, the infected generator was removed, and the lead was cut short. Eight days later, new intravenous caradiac resynchronization therapy pacemaker (CRT-P) implantation was performed. However, despite the repeat debridement, infection at the lead stumps recurred. Moreover, plain chest computed tomography (CT) revealed an abscess around the leads in the anterior mediastinum. Eventually, leads were removed under extracorporeal circulation via re-sternotomy. Postoperative course was uneventful, and she has been doing well without recurrence of infection for 6 years after operation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
213
期刊最新文献
[Concurrent Thymoma and Mature Teratoma in the Mediastinum]. [Coronary Artery Bypass Grafting in a Patient with Hemophilia A Assisted by Thromboelastography: Report of a Case]. [Double-chambered Right Ventricle with Difficult Preoperative Diagnosis of Ventricular Septal Defect in Adulthood]. [Mediastinal Dedifferentiated Liposarcoma Reconstructing Defected Chest Wall Using Prosthetic Materials:Report of a Case]. [Minimally Invasive Aortic Valve Replacement for Aortic Valve Infective Endocarditis Complicated by Septic Arthritis of the Sternoclavicular Joint:Report of a Case].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1