{"title":"内镜黏膜下剥离术后,弹力袜对 D-二聚体水平升高的预防效果。","authors":"Fumito Harada, Shinya Kodashima, Ken Ikusaka, Naoaki Aoki, Yuki Shimizu, Taku Honda, Miyoko Sakurai, Kyohei Maruyama, Hitoshi Aoyagi, Akari Isono, Ryo Miura, Koichiro Abe, Toshihiko Arizumi, Yoshinari Asaoka, Takatsugu Yamamoto, Atsushi Tanaka","doi":"10.1002/deo2.405","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>A relationship between endoscopic submucosal dissection (ESD) and deep vein thrombosis has been recognized. We previously reported that a high corrected midazolam dose (total midazolam dose/initial dose of midazolam used to induce sedation) is related to elevated D-dimer levels after ESD. In this study, the effect of compression stockings (CSs) in preventing thrombosis following ESD under sedation was evaluated by measuring D-dimer levels before and after ESD.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The participants were patients who underwent ESD for upper gastrointestinal tumors during the period between April 2018 and October 2022. Patients with pre-ESD D-dimer levels ≥1.6 µg/m and patients with corrected midazolam doses ≤3.0 were excluded. A retrospective investigation of the relationship between CS use and high post-ESD D-dimer levels (difference in D-dimer levels ≥1.0 µg/mL between before and after ESD) was conducted.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>There were 27 patients in the non-CS group (NCS) and 33 patients in the CS group. The number of patients with high post-ESD D-dimer levels was 13 (48.2%) in the non-CS group and six (18.2%) in the CS group; the number in the CS group was significantly lower (<i>p</i> = 0.024). On logistic regression analysis, a relationship was seen between the wearing of CSs and a lower number of patients with high post-ESD D-dimer levels (odds ratio 0.24, 95% confidence interval 0.08–0.79, <i>p</i> = 0.019).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Wearing CSs was related to a lower risk of high post-ESD D-dimer levels. This result suggests that thrombus formation is a cause of elevated D-dimer levels after ESD.</p>\n </section>\n </div>","PeriodicalId":93973,"journal":{"name":"DEN open","volume":"5 1","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11248715/pdf/","citationCount":"0","resultStr":"{\"title\":\"Prophylactic effect of compression stockings for elevated D-dimer levels following endoscopic submucosal dissection\",\"authors\":\"Fumito Harada, Shinya Kodashima, Ken Ikusaka, Naoaki Aoki, Yuki Shimizu, Taku Honda, Miyoko Sakurai, Kyohei Maruyama, Hitoshi Aoyagi, Akari Isono, Ryo Miura, Koichiro Abe, Toshihiko Arizumi, Yoshinari Asaoka, Takatsugu Yamamoto, Atsushi Tanaka\",\"doi\":\"10.1002/deo2.405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>A relationship between endoscopic submucosal dissection (ESD) and deep vein thrombosis has been recognized. We previously reported that a high corrected midazolam dose (total midazolam dose/initial dose of midazolam used to induce sedation) is related to elevated D-dimer levels after ESD. In this study, the effect of compression stockings (CSs) in preventing thrombosis following ESD under sedation was evaluated by measuring D-dimer levels before and after ESD.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The participants were patients who underwent ESD for upper gastrointestinal tumors during the period between April 2018 and October 2022. Patients with pre-ESD D-dimer levels ≥1.6 µg/m and patients with corrected midazolam doses ≤3.0 were excluded. A retrospective investigation of the relationship between CS use and high post-ESD D-dimer levels (difference in D-dimer levels ≥1.0 µg/mL between before and after ESD) was conducted.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>There were 27 patients in the non-CS group (NCS) and 33 patients in the CS group. The number of patients with high post-ESD D-dimer levels was 13 (48.2%) in the non-CS group and six (18.2%) in the CS group; the number in the CS group was significantly lower (<i>p</i> = 0.024). On logistic regression analysis, a relationship was seen between the wearing of CSs and a lower number of patients with high post-ESD D-dimer levels (odds ratio 0.24, 95% confidence interval 0.08–0.79, <i>p</i> = 0.019).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Wearing CSs was related to a lower risk of high post-ESD D-dimer levels. This result suggests that thrombus formation is a cause of elevated D-dimer levels after ESD.</p>\\n </section>\\n </div>\",\"PeriodicalId\":93973,\"journal\":{\"name\":\"DEN open\",\"volume\":\"5 1\",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11248715/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DEN open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/deo2.405\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEN open","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/deo2.405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Prophylactic effect of compression stockings for elevated D-dimer levels following endoscopic submucosal dissection
Objectives
A relationship between endoscopic submucosal dissection (ESD) and deep vein thrombosis has been recognized. We previously reported that a high corrected midazolam dose (total midazolam dose/initial dose of midazolam used to induce sedation) is related to elevated D-dimer levels after ESD. In this study, the effect of compression stockings (CSs) in preventing thrombosis following ESD under sedation was evaluated by measuring D-dimer levels before and after ESD.
Methods
The participants were patients who underwent ESD for upper gastrointestinal tumors during the period between April 2018 and October 2022. Patients with pre-ESD D-dimer levels ≥1.6 µg/m and patients with corrected midazolam doses ≤3.0 were excluded. A retrospective investigation of the relationship between CS use and high post-ESD D-dimer levels (difference in D-dimer levels ≥1.0 µg/mL between before and after ESD) was conducted.
Results
There were 27 patients in the non-CS group (NCS) and 33 patients in the CS group. The number of patients with high post-ESD D-dimer levels was 13 (48.2%) in the non-CS group and six (18.2%) in the CS group; the number in the CS group was significantly lower (p = 0.024). On logistic regression analysis, a relationship was seen between the wearing of CSs and a lower number of patients with high post-ESD D-dimer levels (odds ratio 0.24, 95% confidence interval 0.08–0.79, p = 0.019).
Conclusion
Wearing CSs was related to a lower risk of high post-ESD D-dimer levels. This result suggests that thrombus formation is a cause of elevated D-dimer levels after ESD.