分析胸腔镜手术中动脉肝素采血器中丢弃不同体积血液样本时的动脉血气值。

IF 1.6 3区 医学 Q2 SURGERY BMC Surgery Pub Date : 2024-07-16 DOI:10.1186/s12893-024-02501-4
Ping Xue, Zhirong Sun
{"title":"分析胸腔镜手术中动脉肝素采血器中丢弃不同体积血液样本时的动脉血气值。","authors":"Ping Xue, Zhirong Sun","doi":"10.1186/s12893-024-02501-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Arterial blood gas analysis (ABGA) plays a vital role in emergency and intensive care, which is affected by many factors, such as different instrumentation, temperature, and testing time. However, there are still no relevant reports on the difference in discarding different blood volumes on ABGA values.</p><p><strong>Methods: </strong>We enrolled 54 patients who underwent thoracoscopic surgery and analysed differences in blood gas analysis results when different blood volumes were discarded from the front line of the arterial heparin blood collector. A paired t test was used to compare the results of the same patient with different volumes of blood discarded from the samples. The difference was corrected by Bonferroni correction.</p><p><strong>Results: </strong>Our results demonstrated that the PaO2, PaCO2, and THbc were more stable in the 4th ml (PaO2 = 231.3600 ± 68.4878 mmHg, PaCO2 = 41.9232 ± 7.4490 mmHg) and 5th ml (PaO2 = 223.7600 ± 12.9895 mmHg, PaCO2 = 42.5679 ± 7.6410 mmHg) blood sample than in the 3rd ml (PaO2 = 234.1000 ± 99.7570 mmHg, PaCO2 = 40.6179 ± 7.2040 mmHg).</p><p><strong>Conclusion: </strong>It may be more appropriate to discard the first 3 ml of blood sample in the analysis of blood gas results without wasting blood samples.</p>","PeriodicalId":49229,"journal":{"name":"BMC Surgery","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11250960/pdf/","citationCount":"0","resultStr":"{\"title\":\"Analysis of arterial blood gas values when discarding different volumes of blood samples in an arterial heparin blood collector during thoracoscopic surgery.\",\"authors\":\"Ping Xue, Zhirong Sun\",\"doi\":\"10.1186/s12893-024-02501-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Arterial blood gas analysis (ABGA) plays a vital role in emergency and intensive care, which is affected by many factors, such as different instrumentation, temperature, and testing time. However, there are still no relevant reports on the difference in discarding different blood volumes on ABGA values.</p><p><strong>Methods: </strong>We enrolled 54 patients who underwent thoracoscopic surgery and analysed differences in blood gas analysis results when different blood volumes were discarded from the front line of the arterial heparin blood collector. A paired t test was used to compare the results of the same patient with different volumes of blood discarded from the samples. The difference was corrected by Bonferroni correction.</p><p><strong>Results: </strong>Our results demonstrated that the PaO2, PaCO2, and THbc were more stable in the 4th ml (PaO2 = 231.3600 ± 68.4878 mmHg, PaCO2 = 41.9232 ± 7.4490 mmHg) and 5th ml (PaO2 = 223.7600 ± 12.9895 mmHg, PaCO2 = 42.5679 ± 7.6410 mmHg) blood sample than in the 3rd ml (PaO2 = 234.1000 ± 99.7570 mmHg, PaCO2 = 40.6179 ± 7.2040 mmHg).</p><p><strong>Conclusion: </strong>It may be more appropriate to discard the first 3 ml of blood sample in the analysis of blood gas results without wasting blood samples.</p>\",\"PeriodicalId\":49229,\"journal\":{\"name\":\"BMC Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11250960/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12893-024-02501-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12893-024-02501-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:动脉血气分析(ABGA)在急诊和重症监护中起着至关重要的作用,它受到许多因素的影响,如不同的仪器、温度和测试时间。然而,目前仍没有相关报告显示放弃不同血容量对 ABGA 值的影响存在差异:方法:我们招募了 54 名接受胸腔镜手术的患者,分析了从动脉肝素采血器前线丢弃不同血量时血气分析结果的差异。采用配对 t 检验来比较同一患者不同样本弃血量的结果。差异经 Bonferroni 校正:结果表明,第 4 毫升(PaO2 = 231.3600 ± 68.4878 mmHg,PaCO2 = 41.9232 ± 7.4490 mmHg)和第 5 毫升(PaO2 = 223.与第 3 毫升血样(PaO2 = 234.1000 ± 99.7570 mmHg,PaCO2 = 40.6179 ± 7.2040 mmHg)相比,第 5 毫升血样(PaO2 = 223.7600 ± 12.9895 mmHg,PaCO2 = 42.5679 ± 7.6410 mmHg)的血氧饱和度更高:结论:在分析血气结果时,舍弃前 3 毫升血液样本可能更合适,且不会浪费血液样本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of arterial blood gas values when discarding different volumes of blood samples in an arterial heparin blood collector during thoracoscopic surgery.

Background: Arterial blood gas analysis (ABGA) plays a vital role in emergency and intensive care, which is affected by many factors, such as different instrumentation, temperature, and testing time. However, there are still no relevant reports on the difference in discarding different blood volumes on ABGA values.

Methods: We enrolled 54 patients who underwent thoracoscopic surgery and analysed differences in blood gas analysis results when different blood volumes were discarded from the front line of the arterial heparin blood collector. A paired t test was used to compare the results of the same patient with different volumes of blood discarded from the samples. The difference was corrected by Bonferroni correction.

Results: Our results demonstrated that the PaO2, PaCO2, and THbc were more stable in the 4th ml (PaO2 = 231.3600 ± 68.4878 mmHg, PaCO2 = 41.9232 ± 7.4490 mmHg) and 5th ml (PaO2 = 223.7600 ± 12.9895 mmHg, PaCO2 = 42.5679 ± 7.6410 mmHg) blood sample than in the 3rd ml (PaO2 = 234.1000 ± 99.7570 mmHg, PaCO2 = 40.6179 ± 7.2040 mmHg).

Conclusion: It may be more appropriate to discard the first 3 ml of blood sample in the analysis of blood gas results without wasting blood samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Surgery
BMC Surgery SURGERY-
CiteScore
2.90
自引率
5.30%
发文量
391
审稿时长
58 days
期刊介绍: BMC Surgery is an open access, peer-reviewed journal that considers articles on surgical research, training, and practice.
期刊最新文献
Real-world study on the application of enhanced recovery after surgery protocol in video-assisted thoracoscopic day surgery for pulmonary nodule resection. The seven-day cumulative post-esophagectomy inflammatory response predicts cancer recurrence. Seprafilm® and adhesive small bowel obstruction in colorectal/abdominal surgery: an updated systematic review. The safety and efficacy of stapler method for transection of the pancreatic parenchyma during pancreatoduodenectomy (STRAP-PD trial): study protocol for a randomized control trial. Challenges and opportunities for Mohs surgery implementation in African healthcare systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1