用可伸缩和生物兼容电极阵列连接神经元-运动通路

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-08-20 Epub Date: 2024-07-18 DOI:10.1021/acs.accounts.4c00215
Zhi Jiang, Ming Zhu, Xiaodong Chen
{"title":"用可伸缩和生物兼容电极阵列连接神经元-运动通路","authors":"Zhi Jiang, Ming Zhu, Xiaodong Chen","doi":"10.1021/acs.accounts.4c00215","DOIUrl":null,"url":null,"abstract":"<p><p>ConspectusIn the field of neuroscience, understanding the complex interactions within the intricate neuron-motor system depends crucially on the use of high-density, physiological multiple electrode arrays (MEAs). In the neuron-motor system, the transmission of biological signals primarily occurs through electrical and chemical signaling. Taking neurons for instance, when a neuron receives external stimuli, it generates an electrical signal known as the action potential. This action potential propagates along the neuron's axon and is transmitted to other neurons via synapses. At the synapse, chemical signals (neurotransmitters) are released, allowing the electrical signal to traverse the synaptic gap and influence the next neuron. MEAs can provide unparalleled insights into neural signal patterns when interfacing with the nerve systems through their excellent spatiotemporal resolution. However, the inherent differences in mechanical and chemical properties between these artificial devices and biological tissues can lead to serious complications after chronic implantation, such as body rejection, infection, tissue damage, or device malfunction. A promising strategy to enhance MEAs' biocompatibility involves minimizing their thickness, which aligns their bending stiffness with that of surrounding tissues, thereby minimizing damage over time. However, this solution has its limits; the resulting ultrathin devices, typically based on plastic films, lack the necessary stretchability, restricting their use to organs that neither stretch nor grow.For practical deployments, devices must exhibit certain levels of stretchability (ranging from 20 to 70%), tailored to the specific requirements of the target organs. In this Account, we outline recent advancements in developing stretchable MEAs that balance stretchability with sufficient electrical conductivity for effective use in physiological research, acting as sensors and stimulators. By concentrating on the neuron-motor pathways, we summarize how the stretchable MEAs meet various application needs and examine their effectiveness. We distinguish between on-skin and implantable uses, given their vastly different requirements. Within each application scope, we highlight cutting-edge technologies, evaluating their strengths and shortcomings. Recognizing that most current devices rely on elastic films with a Young's modulus value between ∼0.5 and 5 MPa, we delve into the potential for softer MEAs, particularly those using multifunctional hydrogels for an optimizing tissue-device interface and address the challenges in adapting such hydrogel-based MEAs for chronic implants. Additionally, transitioning soft MEAs from lab to fab involves connecting them to a rigid adapter and external machinery, highlighting a critical challenge at the soft-rigid interface due to strain concentration, especially in chronic studies subject to unforeseen mechanical strains. We discuss innovative solutions to this integration challenge, being optimistic that the development of durable, biocompatible, stretchable MEAs will significantly advance neuroscience and related fields.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interfacing Neuron-Motor Pathways with Stretchable and Biocompatible Electrode Arrays.\",\"authors\":\"Zhi Jiang, Ming Zhu, Xiaodong Chen\",\"doi\":\"10.1021/acs.accounts.4c00215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>ConspectusIn the field of neuroscience, understanding the complex interactions within the intricate neuron-motor system depends crucially on the use of high-density, physiological multiple electrode arrays (MEAs). In the neuron-motor system, the transmission of biological signals primarily occurs through electrical and chemical signaling. Taking neurons for instance, when a neuron receives external stimuli, it generates an electrical signal known as the action potential. This action potential propagates along the neuron's axon and is transmitted to other neurons via synapses. At the synapse, chemical signals (neurotransmitters) are released, allowing the electrical signal to traverse the synaptic gap and influence the next neuron. MEAs can provide unparalleled insights into neural signal patterns when interfacing with the nerve systems through their excellent spatiotemporal resolution. However, the inherent differences in mechanical and chemical properties between these artificial devices and biological tissues can lead to serious complications after chronic implantation, such as body rejection, infection, tissue damage, or device malfunction. A promising strategy to enhance MEAs' biocompatibility involves minimizing their thickness, which aligns their bending stiffness with that of surrounding tissues, thereby minimizing damage over time. However, this solution has its limits; the resulting ultrathin devices, typically based on plastic films, lack the necessary stretchability, restricting their use to organs that neither stretch nor grow.For practical deployments, devices must exhibit certain levels of stretchability (ranging from 20 to 70%), tailored to the specific requirements of the target organs. In this Account, we outline recent advancements in developing stretchable MEAs that balance stretchability with sufficient electrical conductivity for effective use in physiological research, acting as sensors and stimulators. By concentrating on the neuron-motor pathways, we summarize how the stretchable MEAs meet various application needs and examine their effectiveness. We distinguish between on-skin and implantable uses, given their vastly different requirements. Within each application scope, we highlight cutting-edge technologies, evaluating their strengths and shortcomings. Recognizing that most current devices rely on elastic films with a Young's modulus value between ∼0.5 and 5 MPa, we delve into the potential for softer MEAs, particularly those using multifunctional hydrogels for an optimizing tissue-device interface and address the challenges in adapting such hydrogel-based MEAs for chronic implants. Additionally, transitioning soft MEAs from lab to fab involves connecting them to a rigid adapter and external machinery, highlighting a critical challenge at the soft-rigid interface due to strain concentration, especially in chronic studies subject to unforeseen mechanical strains. We discuss innovative solutions to this integration challenge, being optimistic that the development of durable, biocompatible, stretchable MEAs will significantly advance neuroscience and related fields.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-08-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.accounts.4c00215\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.accounts.4c00215","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

前言 在神经科学领域,要了解错综复杂的神经元-运动系统内部的复杂相互作用,关键在于使用高密度、生理多电极阵列(MEA)。在神经元-运动系统中,生物信号的传递主要通过电子和化学信号进行。以神经元为例,当神经元接收到外部刺激时,会产生称为动作电位的电信号。这种动作电位沿着神经元的轴突传播,并通过突触传递给其他神经元。在突触处,化学信号(神经递质)被释放,使电信号穿过突触间隙,影响下一个神经元。当与神经系统连接时,MEA 凭借其出色的时空分辨率,可以提供对神经信号模式的无与伦比的洞察力。然而,这些人工设备与生物组织之间在机械和化学特性上的固有差异会导致长期植入后出现严重的并发症,如机体排斥、感染、组织损伤或设备故障。增强 MEA 生物相容性的一个可行策略是尽量减小其厚度,使其弯曲刚度与周围组织的弯曲刚度一致,从而最大限度地减少随着时间的推移而造成的损伤。然而,这种解决方案也有其局限性;由此产生的超薄装置通常以塑料薄膜为基础,缺乏必要的伸展性,因此只能用于既不会伸展也不会生长的器官。在本报告中,我们概述了在开发可拉伸 MEA 方面取得的最新进展,这些 MEA 在可拉伸性与足够导电性之间取得了平衡,可有效用于生理研究,充当传感器和刺激器。通过集中研究神经元-运动通路,我们总结了可拉伸 MEA 如何满足各种应用需求并检验其有效性。鉴于皮肤和植入式应用的要求大相径庭,我们对它们进行了区分。在每种应用范围内,我们都重点介绍了前沿技术,评估了它们的优势和不足。我们认识到目前的大多数设备都依赖于杨氏模量值介于 0.5 至 5 兆帕之间的弹性薄膜,因此我们深入研究了更柔软的 MEA 的潜力,特别是那些使用多功能水凝胶来优化组织-设备界面的 MEA,并探讨了将这种基于水凝胶的 MEA 用于慢性植入物所面临的挑战。此外,将软性 MEA 从实验室过渡到工厂需要将其连接到刚性适配器和外部机械,这凸显了软硬界面因应变集中而面临的严峻挑战,尤其是在受到不可预见的机械应变影响的慢性研究中。我们讨论了这一集成挑战的创新解决方案,并乐观地认为,耐用、生物兼容、可拉伸的 MEA 的开发将极大地推动神经科学及相关领域的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Interfacing Neuron-Motor Pathways with Stretchable and Biocompatible Electrode Arrays.

ConspectusIn the field of neuroscience, understanding the complex interactions within the intricate neuron-motor system depends crucially on the use of high-density, physiological multiple electrode arrays (MEAs). In the neuron-motor system, the transmission of biological signals primarily occurs through electrical and chemical signaling. Taking neurons for instance, when a neuron receives external stimuli, it generates an electrical signal known as the action potential. This action potential propagates along the neuron's axon and is transmitted to other neurons via synapses. At the synapse, chemical signals (neurotransmitters) are released, allowing the electrical signal to traverse the synaptic gap and influence the next neuron. MEAs can provide unparalleled insights into neural signal patterns when interfacing with the nerve systems through their excellent spatiotemporal resolution. However, the inherent differences in mechanical and chemical properties between these artificial devices and biological tissues can lead to serious complications after chronic implantation, such as body rejection, infection, tissue damage, or device malfunction. A promising strategy to enhance MEAs' biocompatibility involves minimizing their thickness, which aligns their bending stiffness with that of surrounding tissues, thereby minimizing damage over time. However, this solution has its limits; the resulting ultrathin devices, typically based on plastic films, lack the necessary stretchability, restricting their use to organs that neither stretch nor grow.For practical deployments, devices must exhibit certain levels of stretchability (ranging from 20 to 70%), tailored to the specific requirements of the target organs. In this Account, we outline recent advancements in developing stretchable MEAs that balance stretchability with sufficient electrical conductivity for effective use in physiological research, acting as sensors and stimulators. By concentrating on the neuron-motor pathways, we summarize how the stretchable MEAs meet various application needs and examine their effectiveness. We distinguish between on-skin and implantable uses, given their vastly different requirements. Within each application scope, we highlight cutting-edge technologies, evaluating their strengths and shortcomings. Recognizing that most current devices rely on elastic films with a Young's modulus value between ∼0.5 and 5 MPa, we delve into the potential for softer MEAs, particularly those using multifunctional hydrogels for an optimizing tissue-device interface and address the challenges in adapting such hydrogel-based MEAs for chronic implants. Additionally, transitioning soft MEAs from lab to fab involves connecting them to a rigid adapter and external machinery, highlighting a critical challenge at the soft-rigid interface due to strain concentration, especially in chronic studies subject to unforeseen mechanical strains. We discuss innovative solutions to this integration challenge, being optimistic that the development of durable, biocompatible, stretchable MEAs will significantly advance neuroscience and related fields.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Magnetoelectrics for Implantable Bioelectronics: Progress to Date Emergent Research Trends on the Structural Relaxation Dynamics of Molecular Clusters: From Structure-Property Relationship to New Function Prediction. Chiral Organometallic Complexes Derived from Helicenic N-Heterocyclic Carbenes (NHCs): Design, Structural Diversity, and Chiroptical and Photophysical Properties. Solid-Solution MXenes: Synthesis, Properties, and Applications Selective Functionalization of Alkenes and Alkynes by Dinuclear Manganese Catalysts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1