一名重度多血症患者在导管消融过程中出现的反常发电机阻抗行为

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Arrhythmia Pub Date : 2024-07-10 DOI:10.1002/joa3.13115
Takayuki Sekihara MD, Tomoaki Nakano MD, Akira Yoshida MD, PhD, Takafumi Oka MD, PhD, Yasushi Sakata MD, PhD
{"title":"一名重度多血症患者在导管消融过程中出现的反常发电机阻抗行为","authors":"Takayuki Sekihara MD,&nbsp;Tomoaki Nakano MD,&nbsp;Akira Yoshida MD, PhD,&nbsp;Takafumi Oka MD, PhD,&nbsp;Yasushi Sakata MD, PhD","doi":"10.1002/joa3.13115","DOIUrl":null,"url":null,"abstract":"<p>An extremely high generator impedance in the blood pool can be observed in a patient with severe polycythemia. However, ablation can be performed safely as long as the generator impedance during contact with the myocardial tissue is within acceptable limits.\n <figure>\n <div><picture>\n <source></source></picture><p></p>\n </div>\n </figure></p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 4","pages":"1045-1048"},"PeriodicalIF":2.2000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13115","citationCount":"0","resultStr":"{\"title\":\"Paradoxical generator impedance behavior during catheter ablation in a patient with severe polycythemia\",\"authors\":\"Takayuki Sekihara MD,&nbsp;Tomoaki Nakano MD,&nbsp;Akira Yoshida MD, PhD,&nbsp;Takafumi Oka MD, PhD,&nbsp;Yasushi Sakata MD, PhD\",\"doi\":\"10.1002/joa3.13115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>An extremely high generator impedance in the blood pool can be observed in a patient with severe polycythemia. However, ablation can be performed safely as long as the generator impedance during contact with the myocardial tissue is within acceptable limits.\\n <figure>\\n <div><picture>\\n <source></source></picture><p></p>\\n </div>\\n </figure></p>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"40 4\",\"pages\":\"1045-1048\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13115\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13115\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

在严重多血症患者的血池中可观察到极高的发生器阻抗。不过,只要发生器与心肌组织接触时的阻抗在可接受的范围内,消融手术就可以安全进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Paradoxical generator impedance behavior during catheter ablation in a patient with severe polycythemia

An extremely high generator impedance in the blood pool can be observed in a patient with severe polycythemia. However, ablation can be performed safely as long as the generator impedance during contact with the myocardial tissue is within acceptable limits.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
期刊最新文献
Issue Information Dementia risk reduction between DOACs and VKAs in AF: A systematic review and meta-analysis Electro-anatomically confirmed sites of origin of ventricular tachycardia and premature ventricular contractions and occurrence of R wave in lead aVR: A proof of concept study The Japanese Catheter Ablation Registry (J-AB): Annual report in 2022 Slow left atrial conduction velocity in the anterior wall calculated by electroanatomic mapping predicts atrial fibrillation recurrence after catheter ablation—Systematic review and meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1