在全口义齿中使用可折叠的手术模板,并立即安装

Valeria G. Logunkova, Mahmud M. Mazlum, Alexander V. Kuznetsov
{"title":"在全口义齿中使用可折叠的手术模板,并立即安装","authors":"Valeria G. Logunkova, Mahmud M. Mazlum, Alexander V. Kuznetsov","doi":"10.17816/dd626183","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Complete prosthetics employs the use of collapsible navigable surgical templates, which can effectively mitigate the complications associated with dental implantation at each stage of the process [1–3]. The correct positioning of the implant is of paramount importance, as it directly influences the success of subsequent prosthetics. This is because the planning of the surgical template is conducted simultaneously, taking into account the subsequent prosthetic construction [4–6]. \nAIM: The study aimed to compare the technique of using collapsible surgical templates versus simple ones in complete dentures. \nMATERIALS AND METHODS: The main group consisted of 15 patients, aged 52–70 years, with four women and 11 men. Half of the patients exhibited marked atrophy of the maxilla, while the other half exhibited atrophy of the mandible. All patients underwent the technique of using collapsible surgical templates in full dentures with immediate loading. The control group consisted of 15 patients aged 50–67 years, 6 men and 9 women. They underwent surgery with the use of a conventional surgical navigation template and in whom fixation of the prosthetic structure was performed by the classical method. \nRESULTS: In the primary group, the initial two components of the collapsible template are fixed to the teeth. The template structures are connected to each other with pins, which eliminates micro-vibrations of the initial component. The second template element is then removed. Following the removal of the teeth, the third component of the surgical template is fixed to the pins of the initial component. Following the placement of dental implants, the temporary prosthetic construction is also fixed using a special template. \nThe control group underwent standard surgical technique with a simple surgical template. \nIn the main group, the accuracy of implant positioning, reduction of the risk of complications, and reduction of the operation time were observed. One-stage fixation of the temporary prosthetic structure did not cause aesthetic and functional inconvenience to the patients. In the control group, errors in implant placement were observed in 34% of cases, and intraoperative complications related to neuralgia developed. \nCONCLUSIONS: The use of advanced technology enhances the effectiveness of dental implantation.","PeriodicalId":34831,"journal":{"name":"Digital Diagnostics","volume":"111 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of collapsible surgical templates in full dentures with immediate loading\",\"authors\":\"Valeria G. Logunkova, Mahmud M. Mazlum, Alexander V. Kuznetsov\",\"doi\":\"10.17816/dd626183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND: Complete prosthetics employs the use of collapsible navigable surgical templates, which can effectively mitigate the complications associated with dental implantation at each stage of the process [1–3]. The correct positioning of the implant is of paramount importance, as it directly influences the success of subsequent prosthetics. This is because the planning of the surgical template is conducted simultaneously, taking into account the subsequent prosthetic construction [4–6]. \\nAIM: The study aimed to compare the technique of using collapsible surgical templates versus simple ones in complete dentures. \\nMATERIALS AND METHODS: The main group consisted of 15 patients, aged 52–70 years, with four women and 11 men. Half of the patients exhibited marked atrophy of the maxilla, while the other half exhibited atrophy of the mandible. All patients underwent the technique of using collapsible surgical templates in full dentures with immediate loading. The control group consisted of 15 patients aged 50–67 years, 6 men and 9 women. They underwent surgery with the use of a conventional surgical navigation template and in whom fixation of the prosthetic structure was performed by the classical method. \\nRESULTS: In the primary group, the initial two components of the collapsible template are fixed to the teeth. The template structures are connected to each other with pins, which eliminates micro-vibrations of the initial component. The second template element is then removed. Following the removal of the teeth, the third component of the surgical template is fixed to the pins of the initial component. Following the placement of dental implants, the temporary prosthetic construction is also fixed using a special template. \\nThe control group underwent standard surgical technique with a simple surgical template. \\nIn the main group, the accuracy of implant positioning, reduction of the risk of complications, and reduction of the operation time were observed. One-stage fixation of the temporary prosthetic structure did not cause aesthetic and functional inconvenience to the patients. In the control group, errors in implant placement were observed in 34% of cases, and intraoperative complications related to neuralgia developed. \\nCONCLUSIONS: The use of advanced technology enhances the effectiveness of dental implantation.\",\"PeriodicalId\":34831,\"journal\":{\"name\":\"Digital Diagnostics\",\"volume\":\"111 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digital Diagnostics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17816/dd626183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digital Diagnostics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/dd626183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:全口义齿修复术采用可折叠的可导航手术模板,可有效减少种植牙过程中每个阶段的并发症[1-3]。种植体的正确定位至关重要,因为它直接影响到后续修复的成功与否。这是因为手术模板的规划是同时进行的,要考虑到后续的修复结构[4-6]。目的:本研究旨在比较在全口义齿中使用可折叠手术模板和简单模板的技术。材料和方法:主要研究对象包括 15 名患者,年龄在 52-70 岁之间,其中 4 名女性,11 名男性。其中一半患者上颌骨明显萎缩,另一半患者下颌骨萎缩。所有患者都接受了在全口义齿中使用可折叠手术模板并立即加载的技术。对照组有 15 名患者,年龄在 50-67 岁之间,其中 6 名男性,9 名女性。他们使用传统的手术导航模板进行手术,修复结构的固定采用传统方法。结果:在初级组中,可折叠模板的最初两个组件被固定在牙齿上。模板结构通过销钉相互连接,从而消除了初始组件的微振动。然后取下第二个模板元件。移除牙齿后,将手术模板的第三个组件固定到初始组件的销钉上。植入牙科植入物后,临时修复体也使用特殊模板进行固定。对照组采用标准手术技术,使用简单的手术模板。在主要组中,我们观察到了种植体定位的准确性、并发症风险的降低以及手术时间的缩短。临时假体结构的一段式固定没有给患者带来美观和功能上的不便。在对照组中,34%的病例出现了种植体植入错误,术中出现了与神经痛相关的并发症。结论:先进技术的使用提高了种植牙的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Use of collapsible surgical templates in full dentures with immediate loading
BACKGROUND: Complete prosthetics employs the use of collapsible navigable surgical templates, which can effectively mitigate the complications associated with dental implantation at each stage of the process [1–3]. The correct positioning of the implant is of paramount importance, as it directly influences the success of subsequent prosthetics. This is because the planning of the surgical template is conducted simultaneously, taking into account the subsequent prosthetic construction [4–6]. AIM: The study aimed to compare the technique of using collapsible surgical templates versus simple ones in complete dentures. MATERIALS AND METHODS: The main group consisted of 15 patients, aged 52–70 years, with four women and 11 men. Half of the patients exhibited marked atrophy of the maxilla, while the other half exhibited atrophy of the mandible. All patients underwent the technique of using collapsible surgical templates in full dentures with immediate loading. The control group consisted of 15 patients aged 50–67 years, 6 men and 9 women. They underwent surgery with the use of a conventional surgical navigation template and in whom fixation of the prosthetic structure was performed by the classical method. RESULTS: In the primary group, the initial two components of the collapsible template are fixed to the teeth. The template structures are connected to each other with pins, which eliminates micro-vibrations of the initial component. The second template element is then removed. Following the removal of the teeth, the third component of the surgical template is fixed to the pins of the initial component. Following the placement of dental implants, the temporary prosthetic construction is also fixed using a special template. The control group underwent standard surgical technique with a simple surgical template. In the main group, the accuracy of implant positioning, reduction of the risk of complications, and reduction of the operation time were observed. One-stage fixation of the temporary prosthetic structure did not cause aesthetic and functional inconvenience to the patients. In the control group, errors in implant placement were observed in 34% of cases, and intraoperative complications related to neuralgia developed. CONCLUSIONS: The use of advanced technology enhances the effectiveness of dental implantation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
44
审稿时长
5 weeks
期刊最新文献
A new AI program for the automatic evaluation of scoliosis on frontal spinal radiographs: Accuracy, pros and cons. Conventional and innovative imaging modalities in Bladder Cancer: techniques and applications Possibilities and limitations of MRI diagnostics of endocervical adenocarcinomas of the cervix. An unknown situs viscerum inversus totalis, accidentally discovered after a CT scan The Role of Teleradiology in Interpretation of Ultrasounds Performed in the Emergency Setting
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1