LASIK 术后双侧同时有序植入多焦点人工晶体以矫正屈光。临床病例

E. N. Eskina, A. Belogurova, A. I. Fisenko
{"title":"LASIK 术后双侧同时有序植入多焦点人工晶体以矫正屈光。临床病例","authors":"E. N. Eskina, A. Belogurova, A. I. Fisenko","doi":"10.21516/2072-0076-2024-17-2-108-115","DOIUrl":null,"url":null,"abstract":"The article presents a clinical example of intraocular presbyopia correction in a patient who previously underwent laser vision correction by LASIK for mild myopia. Before the surgery, the distance VA mono- and binocular was 1.0, ADD for reading distance 40 cm +2.0 D, objective refraction sph +0.5 D cyl -0.25 D ax 980, left eye sph +0.75 D cyl -0.25 D ax 660.  The patient was given a simultaneous bilateral refractive lens exchange with an implantation of a trifocal aspheric intraocular lens in the right eye and a trifocal toric aspheric intraocular lens in the left eye. We used the following IOL calculation formulas: ASCRS mean IOL power, Shammas formula, Barrett true K formula, Masket formula, Modified Masket formula, Haigis-L formula. 1 week postop: UDVA OU = 1.0, UNVA 40 cm = 1.0, UVA 70 cm = 0.7. The objective refraction OD was sph +0.0, D cyl -0.75 D ax 163, OS sph +0.25 D, cyl -0.0 D. The compliance with the modified algorithms of pre-and intraoperative behavior of the operating team, thorough preparation of the patient, careful calculation of the IOL allowed us to obtain the predictive refractive result with a high level of visual satisfaction and absence of undesirable postoperative phenomena. The patient underwent the examination with Salzburg reading desk before and after the surgery, to confirm the excellent functional results of the treatment. Despite the fact that simultaneous same day IOL implantation in both eyes, especially in eyes with previously operated corneas, is still disputable, the above case confirms that with modern equipment, precise multi formula calculation, and ample experience help achieve excellent functional and refractive results.","PeriodicalId":21436,"journal":{"name":"Russian Ophthalmological Journal","volume":"144 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simultaneous post-LASIK sequential bilateral implantation of multifocal IOLs aimed at refraction correction. A clinical case\",\"authors\":\"E. N. Eskina, A. Belogurova, A. I. Fisenko\",\"doi\":\"10.21516/2072-0076-2024-17-2-108-115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article presents a clinical example of intraocular presbyopia correction in a patient who previously underwent laser vision correction by LASIK for mild myopia. Before the surgery, the distance VA mono- and binocular was 1.0, ADD for reading distance 40 cm +2.0 D, objective refraction sph +0.5 D cyl -0.25 D ax 980, left eye sph +0.75 D cyl -0.25 D ax 660.  The patient was given a simultaneous bilateral refractive lens exchange with an implantation of a trifocal aspheric intraocular lens in the right eye and a trifocal toric aspheric intraocular lens in the left eye. We used the following IOL calculation formulas: ASCRS mean IOL power, Shammas formula, Barrett true K formula, Masket formula, Modified Masket formula, Haigis-L formula. 1 week postop: UDVA OU = 1.0, UNVA 40 cm = 1.0, UVA 70 cm = 0.7. The objective refraction OD was sph +0.0, D cyl -0.75 D ax 163, OS sph +0.25 D, cyl -0.0 D. The compliance with the modified algorithms of pre-and intraoperative behavior of the operating team, thorough preparation of the patient, careful calculation of the IOL allowed us to obtain the predictive refractive result with a high level of visual satisfaction and absence of undesirable postoperative phenomena. The patient underwent the examination with Salzburg reading desk before and after the surgery, to confirm the excellent functional results of the treatment. Despite the fact that simultaneous same day IOL implantation in both eyes, especially in eyes with previously operated corneas, is still disputable, the above case confirms that with modern equipment, precise multi formula calculation, and ample experience help achieve excellent functional and refractive results.\",\"PeriodicalId\":21436,\"journal\":{\"name\":\"Russian Ophthalmological Journal\",\"volume\":\"144 6\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Russian Ophthalmological Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21516/2072-0076-2024-17-2-108-115\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Ophthalmological Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21516/2072-0076-2024-17-2-108-115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

文章介绍了一个眼内老花矫正的临床案例,患者曾因轻度近视接受过 LASIK 激光视力矫正手术。手术前,单眼和双眼 VA 距离为 1.0,阅读距离 ADD 为 40 cm +2.0 D,客观屈光度 sph +0.5 D cyl -0.25 D ax 980,左眼 sph +0.75 D cyl -0.25 D ax 660。 患者同时接受了双侧屈光晶体置换术,右眼植入一枚三焦点非球面眼内晶体,左眼植入一枚三焦点散光非球面眼内晶体。我们使用了以下人工晶体计算公式:ASCRS 平均 IOL 功率、Shammas 公式、Barrett 真 K 公式、Masket 公式、修正 Masket 公式、Haigis-L 公式。术后 1 周:UDVA OU = 1.0,UNVA 40 cm = 1.0,UVA 70 cm = 0.7。客观屈光度 OD 为 sph +0.0,D cyl -0.75 D ax 163,OS 为 sph +0.25D,cyl -0.0 D。手术团队术前和术中行为遵守修改后的算法,患者准备充分,人工晶体计算仔细,使我们获得了预测的屈光结果,视觉满意度高,术后无不良现象。患者在手术前后接受了萨尔茨堡阅读台检查,以确认治疗的良好功能效果。尽管双眼当天同时植入人工晶体,尤其是在角膜曾接受过手术的双眼中植入人工晶体仍存在争议,但上述病例证实,现代化的设备、精确的多公式计算以及丰富的经验有助于获得极佳的功能和屈光效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A simultaneous post-LASIK sequential bilateral implantation of multifocal IOLs aimed at refraction correction. A clinical case
The article presents a clinical example of intraocular presbyopia correction in a patient who previously underwent laser vision correction by LASIK for mild myopia. Before the surgery, the distance VA mono- and binocular was 1.0, ADD for reading distance 40 cm +2.0 D, objective refraction sph +0.5 D cyl -0.25 D ax 980, left eye sph +0.75 D cyl -0.25 D ax 660.  The patient was given a simultaneous bilateral refractive lens exchange with an implantation of a trifocal aspheric intraocular lens in the right eye and a trifocal toric aspheric intraocular lens in the left eye. We used the following IOL calculation formulas: ASCRS mean IOL power, Shammas formula, Barrett true K formula, Masket formula, Modified Masket formula, Haigis-L formula. 1 week postop: UDVA OU = 1.0, UNVA 40 cm = 1.0, UVA 70 cm = 0.7. The objective refraction OD was sph +0.0, D cyl -0.75 D ax 163, OS sph +0.25 D, cyl -0.0 D. The compliance with the modified algorithms of pre-and intraoperative behavior of the operating team, thorough preparation of the patient, careful calculation of the IOL allowed us to obtain the predictive refractive result with a high level of visual satisfaction and absence of undesirable postoperative phenomena. The patient underwent the examination with Salzburg reading desk before and after the surgery, to confirm the excellent functional results of the treatment. Despite the fact that simultaneous same day IOL implantation in both eyes, especially in eyes with previously operated corneas, is still disputable, the above case confirms that with modern equipment, precise multi formula calculation, and ample experience help achieve excellent functional and refractive results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Endothelial keratoplasty in integrity-damaged iridolenticular diaphragm Scleral collagen crosslinking as a promising direction of sclera-strengthening treatment of progressive myopia Is microbiota a factor in the mechanism of glaucoma development? The effect of silicone oil on the anatomical and functional parameters of the retina during surgery of regmatogenic retinal detachment In memoriam of Abdul-Hamid Davudovich Aliyev
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1