{"title":"基于物联网的血压实时监测系统","authors":"Gusti Made, Ngurah Desnanjaya, I. Made, Aditya Nugraha","doi":"10.11591/ijeecs.v35.i1.pp62-69","DOIUrl":null,"url":null,"abstract":"Blood pressure is an important cardiovascular health indicator, with normal values set by the WHO at 140 mmHg for systole and 90 mmHg for diastole. Excess of these values indicates hypertension, which increases the risk of serious medical complications. This research developed an internet of things (IoT)-based blood pressure monitoring device, which facilitates digital blood pressure measurement and data transmission to widely accessible applications and websites. The device uses an MPX5050GP pressure sensor, Arduino Nano, and NodeMCU ESP32, as well as other components programmed using the Arduino IDE. Test results obtained from 10 subjects, the device showed an average difference in systole of 7.9 mmHg and diastole of 5.4 mmHg. This complies with recognized accuracy standards of a maximum error of 10 mmHg and indicates that the device operates effectively with the designed concept.","PeriodicalId":13480,"journal":{"name":"Indonesian Journal of Electrical Engineering and Computer Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Real-time monitoring system for blood pressure monitoring based on internet of things\",\"authors\":\"Gusti Made, Ngurah Desnanjaya, I. Made, Aditya Nugraha\",\"doi\":\"10.11591/ijeecs.v35.i1.pp62-69\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood pressure is an important cardiovascular health indicator, with normal values set by the WHO at 140 mmHg for systole and 90 mmHg for diastole. Excess of these values indicates hypertension, which increases the risk of serious medical complications. This research developed an internet of things (IoT)-based blood pressure monitoring device, which facilitates digital blood pressure measurement and data transmission to widely accessible applications and websites. The device uses an MPX5050GP pressure sensor, Arduino Nano, and NodeMCU ESP32, as well as other components programmed using the Arduino IDE. Test results obtained from 10 subjects, the device showed an average difference in systole of 7.9 mmHg and diastole of 5.4 mmHg. This complies with recognized accuracy standards of a maximum error of 10 mmHg and indicates that the device operates effectively with the designed concept.\",\"PeriodicalId\":13480,\"journal\":{\"name\":\"Indonesian Journal of Electrical Engineering and Computer Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indonesian Journal of Electrical Engineering and Computer Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/ijeecs.v35.i1.pp62-69\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Electrical Engineering and Computer Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijeecs.v35.i1.pp62-69","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

摘要

血压是一项重要的心血管健康指标,世卫组织规定的正常值为收缩压 140 毫米汞柱,舒张压 90 毫米汞柱。血压超标表明患有高血压,会增加出现严重医疗并发症的风险。这项研究开发了一种基于物联网(IoT)的血压监测设备,便于进行数字血压测量,并将数据传输到可广泛访问的应用程序和网站。该设备使用了 MPX5050GP 压力传感器、Arduino Nano 和 NodeMCU ESP32,以及使用 Arduino IDE 编程的其他组件。10 名受试者的测试结果显示,该设备在收缩期和舒张期的平均压力差分别为 7.9 mmHg 和 5.4 mmHg。这符合公认的最大误差为 10 mmHg 的精确度标准,表明该设备能按照设计理念有效运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Real-time monitoring system for blood pressure monitoring based on internet of things
Blood pressure is an important cardiovascular health indicator, with normal values set by the WHO at 140 mmHg for systole and 90 mmHg for diastole. Excess of these values indicates hypertension, which increases the risk of serious medical complications. This research developed an internet of things (IoT)-based blood pressure monitoring device, which facilitates digital blood pressure measurement and data transmission to widely accessible applications and websites. The device uses an MPX5050GP pressure sensor, Arduino Nano, and NodeMCU ESP32, as well as other components programmed using the Arduino IDE. Test results obtained from 10 subjects, the device showed an average difference in systole of 7.9 mmHg and diastole of 5.4 mmHg. This complies with recognized accuracy standards of a maximum error of 10 mmHg and indicates that the device operates effectively with the designed concept.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
782
期刊介绍: The aim of Indonesian Journal of Electrical Engineering and Computer Science (formerly TELKOMNIKA Indonesian Journal of Electrical Engineering) is to publish high-quality articles dedicated to all aspects of the latest outstanding developments in the field of electrical engineering. Its scope encompasses the applications of Telecommunication and Information Technology, Applied Computing and Computer, Instrumentation and Control, Electrical (Power), Electronics Engineering and Informatics which covers, but not limited to, the following scope: Signal Processing[...] Electronics[...] Electrical[...] Telecommunication[...] Instrumentation & Control[...] Computing and Informatics[...]
期刊最新文献
Sampled-data observer design for sensorless control of wind energy conversion system with PMSG URL shortener for web consumption: an extensive and impressive security algorithm Artificial intelligence powered internet of vehicles: securing connected vehicles in 6G PQ enhancement in grid connected EV charging station using novel GVCR control algorithm for AUPQC device Identification of soluble solid content and total acid content using real-time visual inspection system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1