Michell Ruiz Suárez M.D., José Eduardo Torres Rangel M.D., Rafael Gamba Galeazzi M.D., Antonio César Miguel Lara M.D., Andrés Felipe Cobaleda Aristizabal M.D., Daniel Calderón Hernández M.D.
{"title":"使用可吸收压力消散嵌体缝合盘植入物优化无茎肩关节置换术中的肩胛下肌腱修复术","authors":"Michell Ruiz Suárez M.D., José Eduardo Torres Rangel M.D., Rafael Gamba Galeazzi M.D., Antonio César Miguel Lara M.D., Andrés Felipe Cobaleda Aristizabal M.D., Daniel Calderón Hernández M.D.","doi":"10.1016/j.eats.2024.103094","DOIUrl":null,"url":null,"abstract":"<div><div>Successful subscapularis repair in stemless shoulder arthroplasty is crucial to reduce complications and improve postoperative function. As stemless shoulder arthroplasty continues to grow in popularity, several subscapularis tendon repair techniques are being developed, with a current trend toward knotless devices and double-row anchor-based constructs. In this article, we present our technique for repair of a subscapularis tendon peel using a suture-capture construct that aids in compression of the tendon onto its footprint and then gradually releases the tension as the capture resorbs and tendon healing occurs. The suture-capture tissue repair technology uses a disk or button that pushes down a larger area of tissue onto the bone, eliminating gap formation between the bone and tendon; as the button’s material degrades, compressive, shearing, and tensile forces are transferred to the tendon tissue to achieve complete remodeling of the repair.</div></div>","PeriodicalId":47827,"journal":{"name":"Arthroscopy Techniques","volume":"13 11","pages":"Article 103094"},"PeriodicalIF":1.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of Subscapularis Tendon Repair in Stemless Shoulder Arthroplasty Using a Resorbable Pressure-Dissipating Onlay Suture Disk Implant\",\"authors\":\"Michell Ruiz Suárez M.D., José Eduardo Torres Rangel M.D., Rafael Gamba Galeazzi M.D., Antonio César Miguel Lara M.D., Andrés Felipe Cobaleda Aristizabal M.D., Daniel Calderón Hernández M.D.\",\"doi\":\"10.1016/j.eats.2024.103094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Successful subscapularis repair in stemless shoulder arthroplasty is crucial to reduce complications and improve postoperative function. As stemless shoulder arthroplasty continues to grow in popularity, several subscapularis tendon repair techniques are being developed, with a current trend toward knotless devices and double-row anchor-based constructs. In this article, we present our technique for repair of a subscapularis tendon peel using a suture-capture construct that aids in compression of the tendon onto its footprint and then gradually releases the tension as the capture resorbs and tendon healing occurs. The suture-capture tissue repair technology uses a disk or button that pushes down a larger area of tissue onto the bone, eliminating gap formation between the bone and tendon; as the button’s material degrades, compressive, shearing, and tensile forces are transferred to the tendon tissue to achieve complete remodeling of the repair.</div></div>\",\"PeriodicalId\":47827,\"journal\":{\"name\":\"Arthroscopy Techniques\",\"volume\":\"13 11\",\"pages\":\"Article 103094\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroscopy Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212628724002111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroscopy Techniques","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212628724002111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Optimization of Subscapularis Tendon Repair in Stemless Shoulder Arthroplasty Using a Resorbable Pressure-Dissipating Onlay Suture Disk Implant
Successful subscapularis repair in stemless shoulder arthroplasty is crucial to reduce complications and improve postoperative function. As stemless shoulder arthroplasty continues to grow in popularity, several subscapularis tendon repair techniques are being developed, with a current trend toward knotless devices and double-row anchor-based constructs. In this article, we present our technique for repair of a subscapularis tendon peel using a suture-capture construct that aids in compression of the tendon onto its footprint and then gradually releases the tension as the capture resorbs and tendon healing occurs. The suture-capture tissue repair technology uses a disk or button that pushes down a larger area of tissue onto the bone, eliminating gap formation between the bone and tendon; as the button’s material degrades, compressive, shearing, and tensile forces are transferred to the tendon tissue to achieve complete remodeling of the repair.