在一个大型实验室网络中继续统一国际标准化比值:仪器更换后实验室间差异和偏差持续降低的证据。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-07-18 DOI:10.1093/ajcp/aqae090
Emmanuel J Favaloro, Sandya Arunachalam, Kent Chapman, Leonardo Pasalic
{"title":"在一个大型实验室网络中继续统一国际标准化比值:仪器更换后实验室间差异和偏差持续降低的证据。","authors":"Emmanuel J Favaloro, Sandya Arunachalam, Kent Chapman, Leonardo Pasalic","doi":"10.1093/ajcp/aqae090","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Our objective was to maintain low interlaboratory variation and bias in international normalized ratio (INR) results following a network change in instrumentation and reagents, using a process of ongoing standardization and harmonization.</p><p><strong>Methods: </strong>Network-wide standardization to new common instrument and reagent platforms followed by network-wide application of a simple novel process of verification of international sensitive index and mean normal prothrombin time values for each new lot of prothrombin time (PT) reagent that does not require use of World Health Organization reference thromboplastin or INR calibration/certified plasma.</p><p><strong>Results: </strong>The network transitioned from mechanical hemostasis detection instruments with associated PT reagent (Diagnostica Stago; NeoPTimal) to optical detection (ACL TOPs) with associated PT reagent (Werfen; RecombiPlasTin 2G). Comparing 3 years of data for each situation, the network (n = 27 laboratories) maintained low INR variability and bias relative to general mechanical and optical groups and other laboratories.</p><p><strong>Conclusions: </strong>Harmonized support for patient management of vitamin K antagonists such as warfarin was continuously maintained in our geography, with potentially positive implications for other coagulation laboratories and geographies. For the United States in particular, paucity of US Food and Drug Administration-cleared INR certified plasmas potentially compromises INR test accuracy; our novel approach may provide workable alternatives for other laboratories/networks.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continued harmonization of the international normalized ratio across a large laboratory network: Evidence of sustained low interlaboratory variation and bias after a change in instrumentation.\",\"authors\":\"Emmanuel J Favaloro, Sandya Arunachalam, Kent Chapman, Leonardo Pasalic\",\"doi\":\"10.1093/ajcp/aqae090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Our objective was to maintain low interlaboratory variation and bias in international normalized ratio (INR) results following a network change in instrumentation and reagents, using a process of ongoing standardization and harmonization.</p><p><strong>Methods: </strong>Network-wide standardization to new common instrument and reagent platforms followed by network-wide application of a simple novel process of verification of international sensitive index and mean normal prothrombin time values for each new lot of prothrombin time (PT) reagent that does not require use of World Health Organization reference thromboplastin or INR calibration/certified plasma.</p><p><strong>Results: </strong>The network transitioned from mechanical hemostasis detection instruments with associated PT reagent (Diagnostica Stago; NeoPTimal) to optical detection (ACL TOPs) with associated PT reagent (Werfen; RecombiPlasTin 2G). Comparing 3 years of data for each situation, the network (n = 27 laboratories) maintained low INR variability and bias relative to general mechanical and optical groups and other laboratories.</p><p><strong>Conclusions: </strong>Harmonized support for patient management of vitamin K antagonists such as warfarin was continuously maintained in our geography, with potentially positive implications for other coagulation laboratories and geographies. For the United States in particular, paucity of US Food and Drug Administration-cleared INR certified plasmas potentially compromises INR test accuracy; our novel approach may provide workable alternatives for other laboratories/networks.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ajcp/aqae090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目标我们的目标是在网络更换仪器和试剂后,通过持续的标准化和协调过程,保持国际标准化比值(INR)结果的低实验室间差异和低偏差:方法:在全网络范围内对新的通用仪器和试剂平台进行标准化,然后在全网络范围内采用一种简单的新程序,对每批新的凝血酶原时间(PT)试剂的国际敏感指数和平均正常凝血酶原时间值进行验证,该程序无需使用世界卫生组织参考凝血酶原或 INR 校准/认证血浆:该网络从使用相关 PT 试剂的机械止血检测仪器(Diagnostica Stago;NeoPTimal)过渡到使用相关 PT 试剂的光学检测仪器(ACL TOPs)(Werfen;RecombiPlasTin 2G)。比较每种情况下的 3 年数据,该网络(n = 27 个实验室)与一般机械和光学组及其他实验室相比,保持了较低的 INR 变异性和偏差:结论:在我们所在的地区,对华法林等维生素 K 拮抗剂患者管理的统一支持得以持续保持,这对其他凝血实验室和地区具有潜在的积极意义。特别是在美国,美国食品和药物管理局批准的 INR 认证等离子体的缺乏可能会影响 INR 检测的准确性;我们的新方法可能会为其他实验室/网络提供可行的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continued harmonization of the international normalized ratio across a large laboratory network: Evidence of sustained low interlaboratory variation and bias after a change in instrumentation.

Objectives: Our objective was to maintain low interlaboratory variation and bias in international normalized ratio (INR) results following a network change in instrumentation and reagents, using a process of ongoing standardization and harmonization.

Methods: Network-wide standardization to new common instrument and reagent platforms followed by network-wide application of a simple novel process of verification of international sensitive index and mean normal prothrombin time values for each new lot of prothrombin time (PT) reagent that does not require use of World Health Organization reference thromboplastin or INR calibration/certified plasma.

Results: The network transitioned from mechanical hemostasis detection instruments with associated PT reagent (Diagnostica Stago; NeoPTimal) to optical detection (ACL TOPs) with associated PT reagent (Werfen; RecombiPlasTin 2G). Comparing 3 years of data for each situation, the network (n = 27 laboratories) maintained low INR variability and bias relative to general mechanical and optical groups and other laboratories.

Conclusions: Harmonized support for patient management of vitamin K antagonists such as warfarin was continuously maintained in our geography, with potentially positive implications for other coagulation laboratories and geographies. For the United States in particular, paucity of US Food and Drug Administration-cleared INR certified plasmas potentially compromises INR test accuracy; our novel approach may provide workable alternatives for other laboratories/networks.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1