评估 Sysmex DI-60 集成切片处理系统对血液学鉴别周转时间和患者护理的影响:一家大型退伍军人事务医院的实际实施经验。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-07-19 DOI:10.1093/ajcp/aqae084
Cory R Lundgren
{"title":"评估 Sysmex DI-60 集成切片处理系统对血液学鉴别周转时间和患者护理的影响:一家大型退伍军人事务医院的实际实施经验。","authors":"Cory R Lundgren","doi":"10.1093/ajcp/aqae084","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This quality improvement study conducted at the Kansas City VA Medical Center in Kansas City, Missouri, investigated the Sysmex DI-60 Integrated Slide Processing System's ability to improve hematology turnaround times when integrated into daily practices. It further addressed potential patient care factors associated with changes in turnaround times.</p><p><strong>Methods: </strong>Three months of manual and Sysmex DI-60 patient data were examined between May 2022 and February 2023. White blood cell (WBC) ranges, turnaround times, working hours, and study months were analyzed using 2-tailed unpaired t testing and percentage change. The number of specimens in these categories was further analyzed using 2-tailed, 2-sample proportion testing.</p><p><strong>Results: </strong>This quality improvement study indicated that the Sysmex DI-60 system produced a statisitcally significant reduction in turnaround times overall and for various ranges of WBCs plus work shifts. The most statistically significant improvement in turnaround times occurred for WBC concentrations less than 2.0 × 103/µL and concentrations within the reference range. In addition, the off shifts experienced a notable improvement in turnaround times.</p><p><strong>Conclusions: </strong>The Sysmex DI-60 system substantially decreases turnaround times for differentials, thus potentially benefiting patient care by providing prompt results. It is possible that reducing turnaround times could expedite emergency department admissions and discharges as well as enhance care for the oncology department's patients. It could also lead to more timely results for patients with false-positive flags by the Sysmex analyzer, which may also help with clinician decision-making.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating the Sysmex DI-60 Integrated Slide Processing System's impact on hematology differential turnaround times and patient care: Real-world implementation experience in a large Veterans Affairs hospital.\",\"authors\":\"Cory R Lundgren\",\"doi\":\"10.1093/ajcp/aqae084\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This quality improvement study conducted at the Kansas City VA Medical Center in Kansas City, Missouri, investigated the Sysmex DI-60 Integrated Slide Processing System's ability to improve hematology turnaround times when integrated into daily practices. It further addressed potential patient care factors associated with changes in turnaround times.</p><p><strong>Methods: </strong>Three months of manual and Sysmex DI-60 patient data were examined between May 2022 and February 2023. White blood cell (WBC) ranges, turnaround times, working hours, and study months were analyzed using 2-tailed unpaired t testing and percentage change. The number of specimens in these categories was further analyzed using 2-tailed, 2-sample proportion testing.</p><p><strong>Results: </strong>This quality improvement study indicated that the Sysmex DI-60 system produced a statisitcally significant reduction in turnaround times overall and for various ranges of WBCs plus work shifts. The most statistically significant improvement in turnaround times occurred for WBC concentrations less than 2.0 × 103/µL and concentrations within the reference range. In addition, the off shifts experienced a notable improvement in turnaround times.</p><p><strong>Conclusions: </strong>The Sysmex DI-60 system substantially decreases turnaround times for differentials, thus potentially benefiting patient care by providing prompt results. It is possible that reducing turnaround times could expedite emergency department admissions and discharges as well as enhance care for the oncology department's patients. It could also lead to more timely results for patients with false-positive flags by the Sysmex analyzer, which may also help with clinician decision-making.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ajcp/aqae084\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目标:这项在密苏里州堪萨斯城退伍军人医疗中心进行的质量改进研究调查了 Sysmex DI-60 集成切片处理系统在融入日常实践后改善血液学周转时间的能力。研究还进一步探讨了与周转时间变化相关的潜在病人护理因素:方法:检查了 2022 年 5 月至 2023 年 2 月期间三个月的人工和 Sysmex DI-60 患者数据。使用双尾非配对 t 检验和百分比变化分析了白细胞 (WBC) 范围、周转时间、工作时间和研究月份。使用双尾双样本比例检验进一步分析了这些类别中的标本数量:这项质量改进研究表明,Sysmex DI-60 系统在总体上显著缩短了周转时间,在白细胞和工作班次的不同范围内也是如此。白细胞浓度低于 2.0 × 103/µL 和浓度在参考范围内时,周转时间的缩短在统计学上最为明显。此外,下班班次的周转时间也有明显改善:结论:Sysmex DI-60 系统大大缩短了鉴别的周转时间,从而通过提供及时的结果为病人护理带来潜在的益处。缩短周转时间有可能加快急诊科入院和出院的速度,并加强对肿瘤科病人的护理。它还能为 Sysmex 分析仪出现假阳性信号的病人提供更及时的结果,这也有助于临床医生做出决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluating the Sysmex DI-60 Integrated Slide Processing System's impact on hematology differential turnaround times and patient care: Real-world implementation experience in a large Veterans Affairs hospital.

Objectives: This quality improvement study conducted at the Kansas City VA Medical Center in Kansas City, Missouri, investigated the Sysmex DI-60 Integrated Slide Processing System's ability to improve hematology turnaround times when integrated into daily practices. It further addressed potential patient care factors associated with changes in turnaround times.

Methods: Three months of manual and Sysmex DI-60 patient data were examined between May 2022 and February 2023. White blood cell (WBC) ranges, turnaround times, working hours, and study months were analyzed using 2-tailed unpaired t testing and percentage change. The number of specimens in these categories was further analyzed using 2-tailed, 2-sample proportion testing.

Results: This quality improvement study indicated that the Sysmex DI-60 system produced a statisitcally significant reduction in turnaround times overall and for various ranges of WBCs plus work shifts. The most statistically significant improvement in turnaround times occurred for WBC concentrations less than 2.0 × 103/µL and concentrations within the reference range. In addition, the off shifts experienced a notable improvement in turnaround times.

Conclusions: The Sysmex DI-60 system substantially decreases turnaround times for differentials, thus potentially benefiting patient care by providing prompt results. It is possible that reducing turnaround times could expedite emergency department admissions and discharges as well as enhance care for the oncology department's patients. It could also lead to more timely results for patients with false-positive flags by the Sysmex analyzer, which may also help with clinician decision-making.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1