关节镜下跗关节内杠杆的近端外侧插入门户:尸体研究

IF 1.3 2区 农林科学 Q2 VETERINARY SCIENCES Veterinary Surgery Pub Date : 2024-07-19 DOI:10.1111/vsu.14133
Peter J Lotsikas, Harrison D Ramsey, Nina R Kieves
{"title":"关节镜下跗关节内杠杆的近端外侧插入门户:尸体研究","authors":"Peter J Lotsikas, Harrison D Ramsey, Nina R Kieves","doi":"10.1111/vsu.14133","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To (1) Describe the proximal lateral insertion portal for the placement of an intra-articular distraction lever. (2) Assess for associated damage with the insertion of the lever and (3) evaluate the impact of duration of lever use on articular cartilage damage.</p><p><strong>Study design: </strong>Ex vivo canine cadaveric experimental study.</p><p><strong>Animals: </strong>Paired canine stifles from seven cadavers (14 stifles from dogs weighing >20 kg).</p><p><strong>Methods: </strong>A separate 0.5 cm proximal lateral portal was established adjacent to the lateral scope portal. A standard Ventura stifle thrust lever (VSTL) was inserted without removing the arthroscope. In Group A, the VSTL was placed in distraction for 5 min while in Group B the VSTL was placed for 10 min. The stifle joints were disarticulated and evaluated for associated damage to the long digital extensor tendon and iatrogenic articular cartilage injury (IACI) via India ink assay.</p><p><strong>Results: </strong>No damage to the long digital extensor tendon was noted in any of the specimens during dissection. Superficial IACI was present in all specimens. There were no differences between groups when assessing for overall IACI.</p><p><strong>Conclusion: </strong>A proximal lateral portal and insertion of a standard VSTL can be performed without removing the arthroscope.</p><p><strong>Clinical significance: </strong>The use of a proximal lateral lever portal without repositioning the arthroscope was repeatable without damaging the long digital extensor tendon. A duration of up to 10 min in which the thrust lever was engaged did not result in increased visual cartilage damage.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proximal lateral insertion portal of an intra-articular arthroscopic stifle lever: A cadaveric study.\",\"authors\":\"Peter J Lotsikas, Harrison D Ramsey, Nina R Kieves\",\"doi\":\"10.1111/vsu.14133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To (1) Describe the proximal lateral insertion portal for the placement of an intra-articular distraction lever. (2) Assess for associated damage with the insertion of the lever and (3) evaluate the impact of duration of lever use on articular cartilage damage.</p><p><strong>Study design: </strong>Ex vivo canine cadaveric experimental study.</p><p><strong>Animals: </strong>Paired canine stifles from seven cadavers (14 stifles from dogs weighing >20 kg).</p><p><strong>Methods: </strong>A separate 0.5 cm proximal lateral portal was established adjacent to the lateral scope portal. A standard Ventura stifle thrust lever (VSTL) was inserted without removing the arthroscope. In Group A, the VSTL was placed in distraction for 5 min while in Group B the VSTL was placed for 10 min. The stifle joints were disarticulated and evaluated for associated damage to the long digital extensor tendon and iatrogenic articular cartilage injury (IACI) via India ink assay.</p><p><strong>Results: </strong>No damage to the long digital extensor tendon was noted in any of the specimens during dissection. Superficial IACI was present in all specimens. There were no differences between groups when assessing for overall IACI.</p><p><strong>Conclusion: </strong>A proximal lateral portal and insertion of a standard VSTL can be performed without removing the arthroscope.</p><p><strong>Clinical significance: </strong>The use of a proximal lateral lever portal without repositioning the arthroscope was repeatable without damaging the long digital extensor tendon. A duration of up to 10 min in which the thrust lever was engaged did not result in increased visual cartilage damage.</p>\",\"PeriodicalId\":23667,\"journal\":{\"name\":\"Veterinary Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1111/vsu.14133\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14133","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的目的:(1)描述用于放置关节内牵引杆的近侧插入入口。(2)评估杠杆插入时的相关损伤;(3)评估杠杆使用时间对关节软骨损伤的影响:研究设计:活体犬尸体实验研究:动物:来自 7 具尸体的配对犬胫骨(14 具胫骨来自体重大于 20 千克的犬):方法:在侧窥镜入口附近建立一个单独的 0.5 厘米近端侧门。在不移除关节镜的情况下插入标准的文图拉跗关节推力杆(VSTL)。A 组的 VSTL 放置 5 分钟,B 组的 VSTL 放置 10 分钟。对步枪关节进行解剖,并通过印度墨水检测法评估长伸肌腱的相关损伤和先天性关节软骨损伤(IACI):结果:所有标本在解剖过程中均未发现长伸肌腱损伤。所有标本均存在表层 IACI。在评估整体 IACI 时,各组之间没有差异:临床意义:临床意义:在不重新定位关节镜的情况下使用近侧杠杆入口是可重复的,且不会损伤长的数字伸肌腱。使用推力杆的时间最长可达10分钟,不会导致视觉软骨损伤增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Proximal lateral insertion portal of an intra-articular arthroscopic stifle lever: A cadaveric study.

Objective: To (1) Describe the proximal lateral insertion portal for the placement of an intra-articular distraction lever. (2) Assess for associated damage with the insertion of the lever and (3) evaluate the impact of duration of lever use on articular cartilage damage.

Study design: Ex vivo canine cadaveric experimental study.

Animals: Paired canine stifles from seven cadavers (14 stifles from dogs weighing >20 kg).

Methods: A separate 0.5 cm proximal lateral portal was established adjacent to the lateral scope portal. A standard Ventura stifle thrust lever (VSTL) was inserted without removing the arthroscope. In Group A, the VSTL was placed in distraction for 5 min while in Group B the VSTL was placed for 10 min. The stifle joints were disarticulated and evaluated for associated damage to the long digital extensor tendon and iatrogenic articular cartilage injury (IACI) via India ink assay.

Results: No damage to the long digital extensor tendon was noted in any of the specimens during dissection. Superficial IACI was present in all specimens. There were no differences between groups when assessing for overall IACI.

Conclusion: A proximal lateral portal and insertion of a standard VSTL can be performed without removing the arthroscope.

Clinical significance: The use of a proximal lateral lever portal without repositioning the arthroscope was repeatable without damaging the long digital extensor tendon. A duration of up to 10 min in which the thrust lever was engaged did not result in increased visual cartilage damage.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary Surgery
Veterinary Surgery 农林科学-兽医学
CiteScore
3.40
自引率
22.20%
发文量
162
审稿时长
8-16 weeks
期刊介绍: Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations. It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.
期刊最新文献
Significance of incidentally identified bullae and blebs on thoracic computed tomography and prevalence of subsequent pneumothorax in dogs. Radical surgical excision of extensive perianal melanomas on standing horses: Twenty cases. Application and influence of four drain configurations on fluid dispersal and retrieval in a cadaveric canine wound infusion-retrieval system model. Evaluation of 3D-printed patient-specific guides to facilitate fluoroscopic-assisted Kirschner wire stabilization of simulated capital physeal fractures in 3D-printed dog femur models. Effect of thread direction on rotational stability in lag-screw fixation of sacroiliac luxation: An ex vivo cadaveric study in small-breed dogs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1