心率在反映 2 型糖尿病患者心脏交感神经过度驱动方面的可靠性。

IF 3.9 3区 医学 Q1 CLINICAL NEUROLOGY Clinical Autonomic Research Pub Date : 2024-08-01 Epub Date: 2024-07-22 DOI:10.1007/s10286-024-01054-z
Raffaella Dell'Oro, Fosca Quarti-Trevano, Stefano Ciardullo, Gianluca Perseghin, Giuseppe Mancia, Guido Grassi
{"title":"心率在反映 2 型糖尿病患者心脏交感神经过度驱动方面的可靠性。","authors":"Raffaella Dell'Oro, Fosca Quarti-Trevano, Stefano Ciardullo, Gianluca Perseghin, Giuseppe Mancia, Guido Grassi","doi":"10.1007/s10286-024-01054-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Clinical trials have shown that in type 2 diabetes mellitus (T2D) resting office heart rate (HR) values > 70 beats/minute are associated with an increased cardiovascular risk, a worse prognosis and an unfavorable outcome. The present study was aimed at investigating whether the above mentioned treshold HR values reflect a sympathetic overdrive of marked degree.</p><p><strong>Methods: </strong>In 58 T2D patients (age range: 39-57 years) without signs of autonomic neuropathy and in 52 age-matched healthy controls, we assessed muscle sympathetic nerve activity (MSNA, microneurography) and venous plasma norepinephrine (NE, HPLC), subdividing the study population in different subgroups according to their clinic and 24-h HR values.</p><p><strong>Results: </strong>In T2D progressively greater clinic and 24-h HR values were accompanied by progressive increases in MSNA and NE. HR cutoff values indicated by clinical trials as associated with an increased cardiovascular risk (> 70 beats/minute) were accompanied by MSNA values significantly higher than those detected in patients with lower HR, this being the case also for NE. In T2D both MSNA and NE were significantly related to clinic (r = 0.93, P < 0.0001 and r = 0.87, P < 0.0001, respectively) and 24-h (r = 0.92, P < 0.0001 and r = 0.84, P < 0.0001, respectively) HR. The MSNA and NE behaviour observed in T2D was not detected in healthy controls.</p><p><strong>Conclusions: </strong>In T2D clinic HR values allow to detect patients with a greater sympathetic overactivity. Considering the adverse clinical impact of the sympathetic overdrive on prognosis, our data emphasize the need of future studies investigating the potential usefulness of lifestyle and pharmacological interventions exerting sympathomodulatory effects.</p>","PeriodicalId":10168,"journal":{"name":"Clinical Autonomic Research","volume":" ","pages":"437-445"},"PeriodicalIF":3.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11362466/pdf/","citationCount":"0","resultStr":"{\"title\":\"Reliability of heart rate in reflecting cardiac sympathetic overdrive in type 2 diabetes mellitus.\",\"authors\":\"Raffaella Dell'Oro, Fosca Quarti-Trevano, Stefano Ciardullo, Gianluca Perseghin, Giuseppe Mancia, Guido Grassi\",\"doi\":\"10.1007/s10286-024-01054-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Clinical trials have shown that in type 2 diabetes mellitus (T2D) resting office heart rate (HR) values > 70 beats/minute are associated with an increased cardiovascular risk, a worse prognosis and an unfavorable outcome. The present study was aimed at investigating whether the above mentioned treshold HR values reflect a sympathetic overdrive of marked degree.</p><p><strong>Methods: </strong>In 58 T2D patients (age range: 39-57 years) without signs of autonomic neuropathy and in 52 age-matched healthy controls, we assessed muscle sympathetic nerve activity (MSNA, microneurography) and venous plasma norepinephrine (NE, HPLC), subdividing the study population in different subgroups according to their clinic and 24-h HR values.</p><p><strong>Results: </strong>In T2D progressively greater clinic and 24-h HR values were accompanied by progressive increases in MSNA and NE. HR cutoff values indicated by clinical trials as associated with an increased cardiovascular risk (> 70 beats/minute) were accompanied by MSNA values significantly higher than those detected in patients with lower HR, this being the case also for NE. In T2D both MSNA and NE were significantly related to clinic (r = 0.93, P < 0.0001 and r = 0.87, P < 0.0001, respectively) and 24-h (r = 0.92, P < 0.0001 and r = 0.84, P < 0.0001, respectively) HR. The MSNA and NE behaviour observed in T2D was not detected in healthy controls.</p><p><strong>Conclusions: </strong>In T2D clinic HR values allow to detect patients with a greater sympathetic overactivity. Considering the adverse clinical impact of the sympathetic overdrive on prognosis, our data emphasize the need of future studies investigating the potential usefulness of lifestyle and pharmacological interventions exerting sympathomodulatory effects.</p>\",\"PeriodicalId\":10168,\"journal\":{\"name\":\"Clinical Autonomic Research\",\"volume\":\" \",\"pages\":\"437-445\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11362466/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Autonomic Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10286-024-01054-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Autonomic Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10286-024-01054-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/22 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:临床试验表明,2 型糖尿病(T2D)患者的静息办公室心率(HR)值大于 70 次/分钟与心血管风险增加、预后恶化和结局不利有关。本研究旨在探讨上述阈值心率值是否反映了明显程度的交感神经过度驱动:在 58 名无自主神经病变症状的 T2D 患者(年龄范围:39-57 岁)和 52 名年龄匹配的健康对照者中,我们评估了肌肉交感神经活动(MSNA,微神经电图)和静脉血浆去甲肾上腺素(NE,HPLC),并根据临床和 24 小时 HR 值将研究对象细分为不同的亚组:结果:T2D患者的临床和24小时心率值逐渐升高,同时MSNA和NE也逐渐升高。临床试验表明,心率临界值与心血管风险增加有关(> 70 次/分),而 MSNA 值明显高于心率较低患者的 MSNA 值,NE 也是如此。在 T2D 患者中,MSNA 和 NE 均与临床显著相关(r = 0.93,P 结论):在 T2D 患者中,临床心率值有助于发现交感神经过度活跃的患者。考虑到交感神经功能亢进对预后的不利临床影响,我们的数据强调,今后有必要开展研究,探讨具有交感调节作用的生活方式和药物干预措施的潜在效用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability of heart rate in reflecting cardiac sympathetic overdrive in type 2 diabetes mellitus.

Purpose: Clinical trials have shown that in type 2 diabetes mellitus (T2D) resting office heart rate (HR) values > 70 beats/minute are associated with an increased cardiovascular risk, a worse prognosis and an unfavorable outcome. The present study was aimed at investigating whether the above mentioned treshold HR values reflect a sympathetic overdrive of marked degree.

Methods: In 58 T2D patients (age range: 39-57 years) without signs of autonomic neuropathy and in 52 age-matched healthy controls, we assessed muscle sympathetic nerve activity (MSNA, microneurography) and venous plasma norepinephrine (NE, HPLC), subdividing the study population in different subgroups according to their clinic and 24-h HR values.

Results: In T2D progressively greater clinic and 24-h HR values were accompanied by progressive increases in MSNA and NE. HR cutoff values indicated by clinical trials as associated with an increased cardiovascular risk (> 70 beats/minute) were accompanied by MSNA values significantly higher than those detected in patients with lower HR, this being the case also for NE. In T2D both MSNA and NE were significantly related to clinic (r = 0.93, P < 0.0001 and r = 0.87, P < 0.0001, respectively) and 24-h (r = 0.92, P < 0.0001 and r = 0.84, P < 0.0001, respectively) HR. The MSNA and NE behaviour observed in T2D was not detected in healthy controls.

Conclusions: In T2D clinic HR values allow to detect patients with a greater sympathetic overactivity. Considering the adverse clinical impact of the sympathetic overdrive on prognosis, our data emphasize the need of future studies investigating the potential usefulness of lifestyle and pharmacological interventions exerting sympathomodulatory effects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Autonomic Research
Clinical Autonomic Research 医学-临床神经学
CiteScore
7.40
自引率
6.90%
发文量
65
审稿时长
>12 weeks
期刊介绍: Clinical Autonomic Research aims to draw together and disseminate research work from various disciplines and specialties dealing with clinical problems resulting from autonomic dysfunction. Areas to be covered include: cardiovascular system, neurology, diabetes, endocrinology, urology, pain disorders, ophthalmology, gastroenterology, toxicology and clinical pharmacology, skin infectious diseases, renal disease. This journal is an essential source of new information for everyone working in areas involving the autonomic nervous system. A major feature of Clinical Autonomic Research is its speed of publication coupled with the highest refereeing standards.
期刊最新文献
Comment to the article titled: sympathetic dysfunction as an early indicator of autonomic involvement in Parkinson's disease. Autonomic failure associated with 16p11.2 duplication in two siblings. Adiposity and cardiac autonomic function in children with a family history of obesity. Responses to Valsalva's maneuver in spinal cord injury do not broadly relate to vasoconstrictor capacity. The insular cortex, autonomic asymmetry and cardiovascular control: looking at the right side of stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1