韩国版冠心病自我护理量表第 3 版的心理测试。

IF 2.1 3区 医学 Q2 NURSING Asian Nursing Research Pub Date : 2024-08-01 DOI:10.1016/j.anr.2024.07.001
Jin-Hee Park , Seok Hyun Gwon , Myeong-Ho Yoon , A-Young Lee , Sun Hyoung Bae
{"title":"韩国版冠心病自我护理量表第 3 版的心理测试。","authors":"Jin-Hee Park ,&nbsp;Seok Hyun Gwon ,&nbsp;Myeong-Ho Yoon ,&nbsp;A-Young Lee ,&nbsp;Sun Hyoung Bae","doi":"10.1016/j.anr.2024.07.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>This methodological study evaluated the psychometric properties of the Self-Care of Coronary Heart Disease Inventory version 3 (SC-CHDI v3) in a Korean context.</p></div><div><h3>Methods</h3><p>The SC-CHDI v3 was translated into Korean following a rigorous translation process. Participants were 452 patients who had experienced coronary heart disease (CHD), all recruited from a tertiary hospital in Korea. Exploratory and confirmatory factor analyses were performed to test construct validity. Concurrent validity was examined by correlating scores from the Korean version of the SC-CHDI v3 with those from the Cardiac Self-Efficacy Scale. Internal consistency was analyzed using Cronbach's alpha and McDonald's omega.</p></div><div><h3>Results</h3><p>The Korean version of the SC-CHDI v3 consists of 21 items, excluding two from the original instrument. The self-care maintenance subscale identified a two-factor structure: “treatment adherence” and “health-promoting behaviors.” The goodness-of-fit indices were satisfied: <em>χ</em><sup>2</sup> = 18.19, <em>p</em> = .110, comparative fit index (CFI) = .97, Tucker-Lewis Index (TLI) = .95, and standardized root mean square residual (SRMR) = .04. The self-care monitoring subscale consisted of a one-dimensional structure (“monitoring behaviors”) and the goodness-of-fit indices were satisfied: <em>χ</em><sup>2</sup> = 19.19, <em>p</em> = .059, CFI = .99, TLI = .99, and SRMR = .04. The self-care management subscales had a two-factor structure of “consulting behaviors” and “problem-solving behaviors.” The goodness-of-fit indices were satisfied: <em>χ</em><sup>2</sup> = 16.44, <em>p</em> = .037, CFI = .99, TLI = .98, and SRMR = .03. Scores from the Cardiac Self-Efficacy Scale showed a positive correlation with the Korean version of SC-CHDI v3 subscales. Reliability estimates were ≥ .80 for all subscales except for the self-care maintenance subscale.</p></div><div><h3>Conclusions</h3><p>The Korean version of the SC-CHDI v3 consists of 21 items in 3 subscales and is a valid and reliable instrument. Therefore, healthcare providers can effectively utilize it to assess the self-care levels of patients with CHD.</p></div>","PeriodicalId":55450,"journal":{"name":"Asian Nursing Research","volume":"18 3","pages":"Pages 238-245"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1976131724000689/pdfft?md5=e8b327330f81793a8fe1054be1356c1c&pid=1-s2.0-S1976131724000689-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Psychometric Testing of the Korean Version of the Self-Care of Coronary Heart Disease Inventory Version 3\",\"authors\":\"Jin-Hee Park ,&nbsp;Seok Hyun Gwon ,&nbsp;Myeong-Ho Yoon ,&nbsp;A-Young Lee ,&nbsp;Sun Hyoung Bae\",\"doi\":\"10.1016/j.anr.2024.07.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>This methodological study evaluated the psychometric properties of the Self-Care of Coronary Heart Disease Inventory version 3 (SC-CHDI v3) in a Korean context.</p></div><div><h3>Methods</h3><p>The SC-CHDI v3 was translated into Korean following a rigorous translation process. Participants were 452 patients who had experienced coronary heart disease (CHD), all recruited from a tertiary hospital in Korea. Exploratory and confirmatory factor analyses were performed to test construct validity. Concurrent validity was examined by correlating scores from the Korean version of the SC-CHDI v3 with those from the Cardiac Self-Efficacy Scale. Internal consistency was analyzed using Cronbach's alpha and McDonald's omega.</p></div><div><h3>Results</h3><p>The Korean version of the SC-CHDI v3 consists of 21 items, excluding two from the original instrument. The self-care maintenance subscale identified a two-factor structure: “treatment adherence” and “health-promoting behaviors.” The goodness-of-fit indices were satisfied: <em>χ</em><sup>2</sup> = 18.19, <em>p</em> = .110, comparative fit index (CFI) = .97, Tucker-Lewis Index (TLI) = .95, and standardized root mean square residual (SRMR) = .04. The self-care monitoring subscale consisted of a one-dimensional structure (“monitoring behaviors”) and the goodness-of-fit indices were satisfied: <em>χ</em><sup>2</sup> = 19.19, <em>p</em> = .059, CFI = .99, TLI = .99, and SRMR = .04. The self-care management subscales had a two-factor structure of “consulting behaviors” and “problem-solving behaviors.” The goodness-of-fit indices were satisfied: <em>χ</em><sup>2</sup> = 16.44, <em>p</em> = .037, CFI = .99, TLI = .98, and SRMR = .03. Scores from the Cardiac Self-Efficacy Scale showed a positive correlation with the Korean version of SC-CHDI v3 subscales. Reliability estimates were ≥ .80 for all subscales except for the self-care maintenance subscale.</p></div><div><h3>Conclusions</h3><p>The Korean version of the SC-CHDI v3 consists of 21 items in 3 subscales and is a valid and reliable instrument. Therefore, healthcare providers can effectively utilize it to assess the self-care levels of patients with CHD.</p></div>\",\"PeriodicalId\":55450,\"journal\":{\"name\":\"Asian Nursing Research\",\"volume\":\"18 3\",\"pages\":\"Pages 238-245\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1976131724000689/pdfft?md5=e8b327330f81793a8fe1054be1356c1c&pid=1-s2.0-S1976131724000689-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Nursing Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1976131724000689\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NURSING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Nursing Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1976131724000689","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

摘要

目的:本方法学研究评估了冠心病自我护理量表第 3 版(SC-CHDI v3)在韩国背景下的心理测量特性:SC-CHDI v3经过严格的翻译程序被翻译成韩文。参与者为 452 名冠心病(CHD)患者,均来自韩国一家三级医院。为检验结构效度,进行了探索性和确认性因子分析。通过将韩国版 SC-CHDI v3 的得分与心脏自我效能感量表的得分进行相关性分析,检验了并发效度。采用 Cronbach's alpha 和 McDonald's omega 分析了内部一致性:结果:韩国版 SC-CHDI v3 包括 21 个项目,其中不包括原工具中的两个项目。自我护理维持分量表具有双因素结构:"治疗依从性 "和 "健康促进行为"。拟合优度指数符合要求:χ2 = 18.19,p = 0.110,比较拟合指数 (CFI) = 0.97,塔克-刘易斯指数 (TLI) = 0.95,标准化均方根残差 (SRMR) = 0.04。自我护理监控子量表由一维结构("监控行为")组成,拟合优度指数符合要求:χ2 = 19.19,p = 0.059,CFI = 0.99,TLI = 0.99,SRMR = 0.04。自我护理管理分量表具有 "咨询行为 "和 "解决问题行为 "的双因子结构。拟合优度指数符合要求:χ2 = 16.44,p = .037,CFI = .99,TLI = .98,SRMR = .03。心脏自我效能量表的得分与韩国版 SC-CHDI v3 分量表呈正相关。除自我保健维持量表外,其他所有分量表的信度估计值均≥.80:韩国版 SC-CHDI v3 包括 3 个分量表中的 21 个项目,是一个有效且可靠的工具。因此,医疗服务提供者可以有效地利用它来评估心脏病患者的自我护理水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Psychometric Testing of the Korean Version of the Self-Care of Coronary Heart Disease Inventory Version 3

Purpose

This methodological study evaluated the psychometric properties of the Self-Care of Coronary Heart Disease Inventory version 3 (SC-CHDI v3) in a Korean context.

Methods

The SC-CHDI v3 was translated into Korean following a rigorous translation process. Participants were 452 patients who had experienced coronary heart disease (CHD), all recruited from a tertiary hospital in Korea. Exploratory and confirmatory factor analyses were performed to test construct validity. Concurrent validity was examined by correlating scores from the Korean version of the SC-CHDI v3 with those from the Cardiac Self-Efficacy Scale. Internal consistency was analyzed using Cronbach's alpha and McDonald's omega.

Results

The Korean version of the SC-CHDI v3 consists of 21 items, excluding two from the original instrument. The self-care maintenance subscale identified a two-factor structure: “treatment adherence” and “health-promoting behaviors.” The goodness-of-fit indices were satisfied: χ2 = 18.19, p = .110, comparative fit index (CFI) = .97, Tucker-Lewis Index (TLI) = .95, and standardized root mean square residual (SRMR) = .04. The self-care monitoring subscale consisted of a one-dimensional structure (“monitoring behaviors”) and the goodness-of-fit indices were satisfied: χ2 = 19.19, p = .059, CFI = .99, TLI = .99, and SRMR = .04. The self-care management subscales had a two-factor structure of “consulting behaviors” and “problem-solving behaviors.” The goodness-of-fit indices were satisfied: χ2 = 16.44, p = .037, CFI = .99, TLI = .98, and SRMR = .03. Scores from the Cardiac Self-Efficacy Scale showed a positive correlation with the Korean version of SC-CHDI v3 subscales. Reliability estimates were ≥ .80 for all subscales except for the self-care maintenance subscale.

Conclusions

The Korean version of the SC-CHDI v3 consists of 21 items in 3 subscales and is a valid and reliable instrument. Therefore, healthcare providers can effectively utilize it to assess the self-care levels of patients with CHD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.20
自引率
4.50%
发文量
32
审稿时长
45 days
期刊介绍: Asian Nursing Research is the official peer-reviewed research journal of the Korean Society of Nursing Science, and is devoted to publication of a wide range of research that will contribute to the body of nursing science and inform the practice of nursing, nursing education, administration, and history, on health issues relevant to nursing, and on the testing of research findings in practice.
期刊最新文献
Predictors of nurses' intention to stay: Examining the Impact of Healthcare Policy Involvement. Validity and Reliability of the Korean Version of Supportive Care Needs Survey-Short Form 34 for Patients with Cancer: A Methodological Study. Poor Nutritional Status Predicts Mortality in Patients with Acute Heart Failure Admitted to the Cardiac Intensive Care Unit: A Retrospective Cohort Study. The Mediating Role of Resilience between Dyadic Perceived Social Support and Depression at the Older Adults with Disabilities and their Family Caregivers in China: an Actor-partner Interdependence Model Extended to Mediation. Health Literacy in Fall Prevention Strategy: A Scoping Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1