Akash H Patel, Vishal Patel, Yicheng Tang, Sai Shah, George Tang, Morton J Kern
{"title":"实施 \"无导联[围裙]\"心导管检查:现状。","authors":"Akash H Patel, Vishal Patel, Yicheng Tang, Sai Shah, George Tang, Morton J Kern","doi":"10.1007/s11886-024-02102-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>In this review, we discuss the status of novel radiation shielding and other methods to reduce radiation exposure and its associated health risks within the CCL.</p><p><strong>Recent findings: </strong>There are many devices on the market each with its unique advantages and inherent flaws. Several are available for widespread use with promising data, while others still in development. The field of percutaneous transcatheter interventions includes complex procedures often involving significant radiation exposure. Increased radiation exposes the proceduralist and CCL staff to potential harm from both direct effects of radiation but also from the ergonomic consequences of daily use of heavy personal protective equipment. Here we discuss several innovative efforts to reduce both radiation exposure and orthopedic injury within the CCL that are available, leading to a safer daily routine in a \"lead [apron]-free\" environment.</p>","PeriodicalId":10829,"journal":{"name":"Current Cardiology Reports","volume":" ","pages":"1021-1029"},"PeriodicalIF":3.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379795/pdf/","citationCount":"0","resultStr":"{\"title\":\"Implementing a 'Lead [Apron]-Free' Cardiac Catheterization: Current Status.\",\"authors\":\"Akash H Patel, Vishal Patel, Yicheng Tang, Sai Shah, George Tang, Morton J Kern\",\"doi\":\"10.1007/s11886-024-02102-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>In this review, we discuss the status of novel radiation shielding and other methods to reduce radiation exposure and its associated health risks within the CCL.</p><p><strong>Recent findings: </strong>There are many devices on the market each with its unique advantages and inherent flaws. Several are available for widespread use with promising data, while others still in development. The field of percutaneous transcatheter interventions includes complex procedures often involving significant radiation exposure. Increased radiation exposes the proceduralist and CCL staff to potential harm from both direct effects of radiation but also from the ergonomic consequences of daily use of heavy personal protective equipment. Here we discuss several innovative efforts to reduce both radiation exposure and orthopedic injury within the CCL that are available, leading to a safer daily routine in a \\\"lead [apron]-free\\\" environment.</p>\",\"PeriodicalId\":10829,\"journal\":{\"name\":\"Current Cardiology Reports\",\"volume\":\" \",\"pages\":\"1021-1029\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379795/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Cardiology Reports\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11886-024-02102-w\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Cardiology Reports","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11886-024-02102-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Implementing a 'Lead [Apron]-Free' Cardiac Catheterization: Current Status.
Purpose of review: In this review, we discuss the status of novel radiation shielding and other methods to reduce radiation exposure and its associated health risks within the CCL.
Recent findings: There are many devices on the market each with its unique advantages and inherent flaws. Several are available for widespread use with promising data, while others still in development. The field of percutaneous transcatheter interventions includes complex procedures often involving significant radiation exposure. Increased radiation exposes the proceduralist and CCL staff to potential harm from both direct effects of radiation but also from the ergonomic consequences of daily use of heavy personal protective equipment. Here we discuss several innovative efforts to reduce both radiation exposure and orthopedic injury within the CCL that are available, leading to a safer daily routine in a "lead [apron]-free" environment.
期刊介绍:
The aim of this journal is to provide timely perspectives from experts on current advances in cardiovascular medicine. We also seek to provide reviews that highlight the most important recently published papers selected from the wealth of available cardiovascular literature.
We accomplish this aim by appointing key authorities in major subject areas across the discipline. Section editors select topics to be reviewed by leading experts who emphasize recent developments and highlight important papers published over the past year. An Editorial Board of internationally diverse members suggests topics of special interest to their country/region and ensures that topics are current and include emerging research. We also provide commentaries from well-known figures in the field.