{"title":"放射诊断中碘化造影剂引起的超敏反应:基于 FAERS 数据库的比例失调分析。","authors":"Jinjin Long, Yifan Yi, Yawen Zhang, Xinghui Li","doi":"10.2174/0115734056306358240607115422","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the Pharmacovigilance (PV) and severity of hypersensitivity reactions induced by non-ionic Iodinated Contrast Media (ICM) in the radiology diagnosis reported to the United States Food and Drug Administration Adverse Event Reporting System (FAERS).</p><p><strong>Methods: </strong>We retrospectively reviewed the reports of ICM-induced hypersensitivity reactions submitted to the FAERS database between January 2015 and January 2023 and conducted a disproportionality analysis. The seven most common non-ionic ICM, including iohexol, iopamidol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, were chiefly analyzed. Our primary endpoint was the PV of non-ionic ICM-induced total hypersensitivity events. STATA 17.0 MP was used for statistical analysis.</p><p><strong>Results: </strong>In total, 35357 reports of adverse reaction events in radiology diagnosis were retrieved from the FAERS database. Among them, 6181 reports were on hypersensitivity reaction events (mean age: 57.1 ± 17.8 years). The hypersensitivity reaction-related PV signal was detected for iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, but not for iopamidol. The proportion of iomeprol-induced hypersensitivity reactions and the probability of ioversol-induced severe hypersensitivity reactions have been found to be significantly increased.</p><p><strong>Conclusion: </strong>The probability and severity of hypersensitivity reaction events in non-ionic ICM are different. Iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol have higher risks compared to iopamidol. In addition, the constituent ratio of hypersensitivity reactions induced by iomeprol is significantly increased, and the associated probability induced by ioversol is significantly increased.</p>","PeriodicalId":54215,"journal":{"name":"Current Medical Imaging Reviews","volume":"20 1","pages":"e15734056306358"},"PeriodicalIF":1.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hypersensitivity Reactions Induced by Iodinated Contrast Media in Radiological Diagnosis: A Disproportionality Analysis Based on the FAERS Database.\",\"authors\":\"Jinjin Long, Yifan Yi, Yawen Zhang, Xinghui Li\",\"doi\":\"10.2174/0115734056306358240607115422\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to evaluate the Pharmacovigilance (PV) and severity of hypersensitivity reactions induced by non-ionic Iodinated Contrast Media (ICM) in the radiology diagnosis reported to the United States Food and Drug Administration Adverse Event Reporting System (FAERS).</p><p><strong>Methods: </strong>We retrospectively reviewed the reports of ICM-induced hypersensitivity reactions submitted to the FAERS database between January 2015 and January 2023 and conducted a disproportionality analysis. The seven most common non-ionic ICM, including iohexol, iopamidol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, were chiefly analyzed. Our primary endpoint was the PV of non-ionic ICM-induced total hypersensitivity events. STATA 17.0 MP was used for statistical analysis.</p><p><strong>Results: </strong>In total, 35357 reports of adverse reaction events in radiology diagnosis were retrieved from the FAERS database. Among them, 6181 reports were on hypersensitivity reaction events (mean age: 57.1 ± 17.8 years). The hypersensitivity reaction-related PV signal was detected for iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, but not for iopamidol. The proportion of iomeprol-induced hypersensitivity reactions and the probability of ioversol-induced severe hypersensitivity reactions have been found to be significantly increased.</p><p><strong>Conclusion: </strong>The probability and severity of hypersensitivity reaction events in non-ionic ICM are different. Iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol have higher risks compared to iopamidol. In addition, the constituent ratio of hypersensitivity reactions induced by iomeprol is significantly increased, and the associated probability induced by ioversol is significantly increased.</p>\",\"PeriodicalId\":54215,\"journal\":{\"name\":\"Current Medical Imaging Reviews\",\"volume\":\"20 1\",\"pages\":\"e15734056306358\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Medical Imaging Reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2174/0115734056306358240607115422\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Medical Imaging Reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2174/0115734056306358240607115422","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Hypersensitivity Reactions Induced by Iodinated Contrast Media in Radiological Diagnosis: A Disproportionality Analysis Based on the FAERS Database.
Purpose: This study aimed to evaluate the Pharmacovigilance (PV) and severity of hypersensitivity reactions induced by non-ionic Iodinated Contrast Media (ICM) in the radiology diagnosis reported to the United States Food and Drug Administration Adverse Event Reporting System (FAERS).
Methods: We retrospectively reviewed the reports of ICM-induced hypersensitivity reactions submitted to the FAERS database between January 2015 and January 2023 and conducted a disproportionality analysis. The seven most common non-ionic ICM, including iohexol, iopamidol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, were chiefly analyzed. Our primary endpoint was the PV of non-ionic ICM-induced total hypersensitivity events. STATA 17.0 MP was used for statistical analysis.
Results: In total, 35357 reports of adverse reaction events in radiology diagnosis were retrieved from the FAERS database. Among them, 6181 reports were on hypersensitivity reaction events (mean age: 57.1 ± 17.8 years). The hypersensitivity reaction-related PV signal was detected for iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, but not for iopamidol. The proportion of iomeprol-induced hypersensitivity reactions and the probability of ioversol-induced severe hypersensitivity reactions have been found to be significantly increased.
Conclusion: The probability and severity of hypersensitivity reaction events in non-ionic ICM are different. Iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol have higher risks compared to iopamidol. In addition, the constituent ratio of hypersensitivity reactions induced by iomeprol is significantly increased, and the associated probability induced by ioversol is significantly increased.
期刊介绍:
Current Medical Imaging Reviews publishes frontier review articles, original research articles, drug clinical trial studies and guest edited thematic issues on all the latest advances on medical imaging dedicated to clinical research. All relevant areas are covered by the journal, including advances in the diagnosis, instrumentation and therapeutic applications related to all modern medical imaging techniques.
The journal is essential reading for all clinicians and researchers involved in medical imaging and diagnosis.