用于血癌检测的高性能等离子体生物传感器:实现超高效价比

IF 3.3 4区 物理与天体物理 Q2 CHEMISTRY, PHYSICAL Plasmonics Pub Date : 2024-07-27 DOI:10.1007/s11468-024-02429-8
Yashaswini Singh, Adarsh Chandra Mishra, Sapana Yadav, Laxmi Jaiswal, Pooja Lohia, D. K. Dwivedi, R. K. Yadav, Gaber E. Eldesoky, M. Khalid Hossain
{"title":"用于血癌检测的高性能等离子体生物传感器:实现超高效价比","authors":"Yashaswini Singh, Adarsh Chandra Mishra, Sapana Yadav, Laxmi Jaiswal, Pooja Lohia, D. K. Dwivedi, R. K. Yadav, Gaber E. Eldesoky, M. Khalid Hossain","doi":"10.1007/s11468-024-02429-8","DOIUrl":null,"url":null,"abstract":"<p>A highly sensitive hybrid structure for biosensing application based on surface plasmon resonance for the detection of blood cancer has been proposed in this article. The biosensor comprises of a CaF<sub>2</sub> Prism, Ag metal, an oxide layer Al<sub>2</sub>O<sub>3</sub> and a 2D nanomaterial graphene, which is grounded on Kretschmann configuration. The transfer matrix method is used to interrogate the performance parameters of proposed biosensor. To analyze the change in refractive index, the analyte has been considered over the graphene layer. To achieve maximum sensitivity and minimum reflectance the thickness of Ag, Al<sub>2</sub>O<sub>3</sub> layers and number of graphene layers have been optimized. The suggested structure’s sensitivity can be enhanced up to 427.43 deg/RIU with the optimized value for the detection accuracy and FOM of 0.7027 deg<sup>−1</sup> and 217 RIU<sup>−1</sup> respectively. The work focuses on the development of plasmonic sensors with high performance and stability. Role of different material layers is also analyzed in terms of enhancement in sensitivity and evanescent field. The paper offers better optimization technique and selection of material than previously reported works, which eventually leads to enhancement in both sensitivity and FOM. This research could lead to the development of a useful biological sample sensing tool for the quick and precise detection of the blood cancer in its early stages.</p>","PeriodicalId":736,"journal":{"name":"Plasmonics","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-Performance Plasmonic Biosensor for Blood Cancer Detection: Achieving Ultrahigh Figure-of-Merit\",\"authors\":\"Yashaswini Singh, Adarsh Chandra Mishra, Sapana Yadav, Laxmi Jaiswal, Pooja Lohia, D. K. Dwivedi, R. K. Yadav, Gaber E. Eldesoky, M. Khalid Hossain\",\"doi\":\"10.1007/s11468-024-02429-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A highly sensitive hybrid structure for biosensing application based on surface plasmon resonance for the detection of blood cancer has been proposed in this article. The biosensor comprises of a CaF<sub>2</sub> Prism, Ag metal, an oxide layer Al<sub>2</sub>O<sub>3</sub> and a 2D nanomaterial graphene, which is grounded on Kretschmann configuration. The transfer matrix method is used to interrogate the performance parameters of proposed biosensor. To analyze the change in refractive index, the analyte has been considered over the graphene layer. To achieve maximum sensitivity and minimum reflectance the thickness of Ag, Al<sub>2</sub>O<sub>3</sub> layers and number of graphene layers have been optimized. The suggested structure’s sensitivity can be enhanced up to 427.43 deg/RIU with the optimized value for the detection accuracy and FOM of 0.7027 deg<sup>−1</sup> and 217 RIU<sup>−1</sup> respectively. The work focuses on the development of plasmonic sensors with high performance and stability. Role of different material layers is also analyzed in terms of enhancement in sensitivity and evanescent field. The paper offers better optimization technique and selection of material than previously reported works, which eventually leads to enhancement in both sensitivity and FOM. This research could lead to the development of a useful biological sample sensing tool for the quick and precise detection of the blood cancer in its early stages.</p>\",\"PeriodicalId\":736,\"journal\":{\"name\":\"Plasmonics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasmonics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1007/s11468-024-02429-8\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasmonics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1007/s11468-024-02429-8","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种基于表面等离子体共振的高灵敏度混合结构生物传感应用,用于检测血癌。该生物传感器由 CaF2 棱镜、银金属、氧化层 Al2O3 和二维纳米材料石墨烯组成,并以 Kretschmann 构型接地。传递矩阵法用于检测拟议生物传感器的性能参数。为了分析折射率的变化,分析物被考虑覆盖在石墨烯层上。为了达到最高灵敏度和最低反射率,对银层、Al2O3 层的厚度和石墨烯层的数量进行了优化。建议结构的灵敏度可提高到 427.43 deg/RIU,检测精度和 FOM 的优化值分别为 0.7027 deg-1 和 217 RIU-1。这项工作的重点是开发具有高性能和高稳定性的等离子体传感器。论文还分析了不同材料层在提高灵敏度和增强蒸发场方面的作用。与以前的研究相比,本文提供了更好的优化技术和材料选择,最终提高了灵敏度和 FOM。这项研究可以开发出一种有用的生物样本传感工具,用于快速、精确地检测早期血癌。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-Performance Plasmonic Biosensor for Blood Cancer Detection: Achieving Ultrahigh Figure-of-Merit

A highly sensitive hybrid structure for biosensing application based on surface plasmon resonance for the detection of blood cancer has been proposed in this article. The biosensor comprises of a CaF2 Prism, Ag metal, an oxide layer Al2O3 and a 2D nanomaterial graphene, which is grounded on Kretschmann configuration. The transfer matrix method is used to interrogate the performance parameters of proposed biosensor. To analyze the change in refractive index, the analyte has been considered over the graphene layer. To achieve maximum sensitivity and minimum reflectance the thickness of Ag, Al2O3 layers and number of graphene layers have been optimized. The suggested structure’s sensitivity can be enhanced up to 427.43 deg/RIU with the optimized value for the detection accuracy and FOM of 0.7027 deg−1 and 217 RIU−1 respectively. The work focuses on the development of plasmonic sensors with high performance and stability. Role of different material layers is also analyzed in terms of enhancement in sensitivity and evanescent field. The paper offers better optimization technique and selection of material than previously reported works, which eventually leads to enhancement in both sensitivity and FOM. This research could lead to the development of a useful biological sample sensing tool for the quick and precise detection of the blood cancer in its early stages.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Plasmonics
Plasmonics 工程技术-材料科学:综合
CiteScore
5.90
自引率
6.70%
发文量
164
审稿时长
2.1 months
期刊介绍: Plasmonics is an international forum for the publication of peer-reviewed leading-edge original articles that both advance and report our knowledge base and practice of the interactions of free-metal electrons, Plasmons. Topics covered include notable advances in the theory, Physics, and applications of surface plasmons in metals, to the rapidly emerging areas of nanotechnology, biophotonics, sensing, biochemistry and medicine. Topics, including the theory, synthesis and optical properties of noble metal nanostructures, patterned surfaces or materials, continuous or grated surfaces, devices, or wires for their multifarious applications are particularly welcome. Typical applications might include but are not limited to, surface enhanced spectroscopic properties, such as Raman scattering or fluorescence, as well developments in techniques such as surface plasmon resonance and near-field scanning optical microscopy.
期刊最新文献
Comparative Analysis of Two Different MIM Configurations of a Plasmonic Nanoantenna On the Transmission Line Analogy for Modeling Plasmonic Nanowire Circuits Terahertz-Multiplexed Metallic Metasurfaces for Enhanced Trace Sample Absorption Plasmonic Characteristics of LiF Filled Slab Waveguide in Isotropic Plasma Environment Synthesis, Characterization, and Modeling of Reduced Graphene Oxide Supported Adsorbent for Sorption of Pb(II) and Cr(VI) Ions from Binary Mixture
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1