免疫吸附和血浆置换在抗中性粒细胞胞浆抗体或抗肾小球基底膜清除动力学方面具有可比性

IF 8.3 2区 材料科学 Q1 MATERIALS SCIENCE, MULTIDISCIPLINARY ACS Applied Materials & Interfaces Pub Date : 2024-09-01 DOI:10.1016/j.ekir.2024.06.031
Marion Sallee , Noémie Resseguier , Thomas Crepin , Daniel Bertin , Dominique Bertrand , Mickaël Bobot , Thierry Krummel , Nicolas Maillard , Julie Moussi-Frances , Marion Pelletier , Pascale Poullin , Cédric Rafat , Thomas Robert , Benjamin Terrier , Lionel Rostaing , Stanislas Faguer , Noémie Jourde-Chiche
{"title":"免疫吸附和血浆置换在抗中性粒细胞胞浆抗体或抗肾小球基底膜清除动力学方面具有可比性","authors":"Marion Sallee ,&nbsp;Noémie Resseguier ,&nbsp;Thomas Crepin ,&nbsp;Daniel Bertin ,&nbsp;Dominique Bertrand ,&nbsp;Mickaël Bobot ,&nbsp;Thierry Krummel ,&nbsp;Nicolas Maillard ,&nbsp;Julie Moussi-Frances ,&nbsp;Marion Pelletier ,&nbsp;Pascale Poullin ,&nbsp;Cédric Rafat ,&nbsp;Thomas Robert ,&nbsp;Benjamin Terrier ,&nbsp;Lionel Rostaing ,&nbsp;Stanislas Faguer ,&nbsp;Noémie Jourde-Chiche","doi":"10.1016/j.ekir.2024.06.031","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Apheresis allows the fast removal of autoantibodies in anti-glomerular basement membrane (anti-GBM) disease, and in severe antineutrophil cytoplasmic antibodies (ANCA)-associated vasculitis. The CINEVAS study tested whether immunoadsorption (IA) allowed a faster removal of ANCA and/or anti-GBM antibodies than plasma exchanges (PEx).</p></div><div><h3>Methods</h3><p>CINEVAS was a prospective multicenter study comparing IA to PEx in consecutive patients with ANCA and/or anti-GBM vasculitides. The primary objective was the reduction rate in autoantibody titers between the beginning of the first and the end of the seventh apheresis session. Secondary objectives were number of sessions needed to obtain desired reduction rates; reduction rates of total Ig levels; tolerance of sessions; and patients’ outcome.</p></div><div><h3>Results</h3><p>The results of 38 patients (16 treated with IA and 22 with PEx), and 43 autoantibodies, were analyzed. There was no difference in the reduction rates in autoantibody titers between IA and PEx over 7 sessions (respectively 98% vs. 96%, <em>P</em> = 0.39). The numbers of sessions needed to obtain undetectable autoantibodies, or 50%, 75%, or 90% reductions, did not differ between techniques. Greater reduction rates of autoantibodies were observed when plasma was separated by filtration compared to centrifugation, with IA and PEx. IA allowed a greater reduction in total IgG levels, and better preservation of total IgA and IgM levels than PEx. PEx sessions required higher volumes of plasma, IA sessions higher volumes of citrate; IA sessions were longer.</p></div><div><h3>Conclusions</h3><p>IA and PEx were comparable in ANCA or anti-GBM removal kinetics, despite a faster reduction in total IgG with IA.</p></div>","PeriodicalId":5,"journal":{"name":"ACS Applied Materials & Interfaces","volume":null,"pages":null},"PeriodicalIF":8.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2468024924018084/pdfft?md5=16d17670cc0ed6a5718a3d9ca4673521&pid=1-s2.0-S2468024924018084-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Immunoadsorption and Plasma Exchange are Comparable in Anti-Neutrophil Cytoplasmic Antibodies or Anti-Glomerular Basement Membrane Removal Kinetics\",\"authors\":\"Marion Sallee ,&nbsp;Noémie Resseguier ,&nbsp;Thomas Crepin ,&nbsp;Daniel Bertin ,&nbsp;Dominique Bertrand ,&nbsp;Mickaël Bobot ,&nbsp;Thierry Krummel ,&nbsp;Nicolas Maillard ,&nbsp;Julie Moussi-Frances ,&nbsp;Marion Pelletier ,&nbsp;Pascale Poullin ,&nbsp;Cédric Rafat ,&nbsp;Thomas Robert ,&nbsp;Benjamin Terrier ,&nbsp;Lionel Rostaing ,&nbsp;Stanislas Faguer ,&nbsp;Noémie Jourde-Chiche\",\"doi\":\"10.1016/j.ekir.2024.06.031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Apheresis allows the fast removal of autoantibodies in anti-glomerular basement membrane (anti-GBM) disease, and in severe antineutrophil cytoplasmic antibodies (ANCA)-associated vasculitis. The CINEVAS study tested whether immunoadsorption (IA) allowed a faster removal of ANCA and/or anti-GBM antibodies than plasma exchanges (PEx).</p></div><div><h3>Methods</h3><p>CINEVAS was a prospective multicenter study comparing IA to PEx in consecutive patients with ANCA and/or anti-GBM vasculitides. The primary objective was the reduction rate in autoantibody titers between the beginning of the first and the end of the seventh apheresis session. Secondary objectives were number of sessions needed to obtain desired reduction rates; reduction rates of total Ig levels; tolerance of sessions; and patients’ outcome.</p></div><div><h3>Results</h3><p>The results of 38 patients (16 treated with IA and 22 with PEx), and 43 autoantibodies, were analyzed. There was no difference in the reduction rates in autoantibody titers between IA and PEx over 7 sessions (respectively 98% vs. 96%, <em>P</em> = 0.39). The numbers of sessions needed to obtain undetectable autoantibodies, or 50%, 75%, or 90% reductions, did not differ between techniques. Greater reduction rates of autoantibodies were observed when plasma was separated by filtration compared to centrifugation, with IA and PEx. IA allowed a greater reduction in total IgG levels, and better preservation of total IgA and IgM levels than PEx. PEx sessions required higher volumes of plasma, IA sessions higher volumes of citrate; IA sessions were longer.</p></div><div><h3>Conclusions</h3><p>IA and PEx were comparable in ANCA or anti-GBM removal kinetics, despite a faster reduction in total IgG with IA.</p></div>\",\"PeriodicalId\":5,\"journal\":{\"name\":\"ACS Applied Materials & Interfaces\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2468024924018084/pdfft?md5=16d17670cc0ed6a5718a3d9ca4673521&pid=1-s2.0-S2468024924018084-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Materials & Interfaces\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2468024924018084\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Materials & Interfaces","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468024924018084","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在抗肾小球基底膜(anti-GBM)疾病和严重的抗中性粒细胞胞浆抗体(ANCA)相关性血管炎中,免疫吸附可快速清除自身抗体。CINEVAS研究测试了免疫吸附(IA)是否能比血浆置换(PEx)更快地清除ANCA和/或抗GBM抗体。CINEVAS是一项前瞻性多中心研究,对ANCA和/或抗-GBM血管炎连续患者进行免疫吸附与血浆置换的比较。研究的首要目标是第一次无细胞疗法开始到第七次无细胞疗法结束时自身抗体滴度的降低率。次要目标是获得理想降低率所需的疗程次数、总Ig水平降低率、疗程耐受性和患者疗效。研究分析了38名患者(16名接受IA治疗,22名接受PEx治疗)和43种自身抗体的结果。在 7 个疗程中,IA 和 PEx 的自身抗体滴度降低率没有差异(分别为 98% 对 96%,= 0.39)。获得检测不到的自身抗体或50%、75%或90%的降低率所需的疗程次数在不同技术之间没有差异。与离心分离血浆相比,IA 和 PEx 过滤分离血浆的自身抗体减少率更高。与 PEx 相比,IA 能更大程度地降低总 IgG 水平,更好地保留总 IgA 和 IgM 水平。PEx疗程需要更多的血浆,IA疗程需要更多的枸橼酸;IA疗程更长。在 ANCA 或抗 GBM 清除动力学方面,IA 和 PEx 具有可比性,尽管 IA 能更快地减少总 IgG。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Immunoadsorption and Plasma Exchange are Comparable in Anti-Neutrophil Cytoplasmic Antibodies or Anti-Glomerular Basement Membrane Removal Kinetics

Introduction

Apheresis allows the fast removal of autoantibodies in anti-glomerular basement membrane (anti-GBM) disease, and in severe antineutrophil cytoplasmic antibodies (ANCA)-associated vasculitis. The CINEVAS study tested whether immunoadsorption (IA) allowed a faster removal of ANCA and/or anti-GBM antibodies than plasma exchanges (PEx).

Methods

CINEVAS was a prospective multicenter study comparing IA to PEx in consecutive patients with ANCA and/or anti-GBM vasculitides. The primary objective was the reduction rate in autoantibody titers between the beginning of the first and the end of the seventh apheresis session. Secondary objectives were number of sessions needed to obtain desired reduction rates; reduction rates of total Ig levels; tolerance of sessions; and patients’ outcome.

Results

The results of 38 patients (16 treated with IA and 22 with PEx), and 43 autoantibodies, were analyzed. There was no difference in the reduction rates in autoantibody titers between IA and PEx over 7 sessions (respectively 98% vs. 96%, P = 0.39). The numbers of sessions needed to obtain undetectable autoantibodies, or 50%, 75%, or 90% reductions, did not differ between techniques. Greater reduction rates of autoantibodies were observed when plasma was separated by filtration compared to centrifugation, with IA and PEx. IA allowed a greater reduction in total IgG levels, and better preservation of total IgA and IgM levels than PEx. PEx sessions required higher volumes of plasma, IA sessions higher volumes of citrate; IA sessions were longer.

Conclusions

IA and PEx were comparable in ANCA or anti-GBM removal kinetics, despite a faster reduction in total IgG with IA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Materials & Interfaces
ACS Applied Materials & Interfaces 工程技术-材料科学:综合
CiteScore
16.00
自引率
6.30%
发文量
4978
审稿时长
1.8 months
期刊介绍: ACS Applied Materials & Interfaces is a leading interdisciplinary journal that brings together chemists, engineers, physicists, and biologists to explore the development and utilization of newly-discovered materials and interfacial processes for specific applications. Our journal has experienced remarkable growth since its establishment in 2009, both in terms of the number of articles published and the impact of the research showcased. We are proud to foster a truly global community, with the majority of published articles originating from outside the United States, reflecting the rapid growth of applied research worldwide.
期刊最新文献
Decreased levels of phosphorylated synuclein in plasma are correlated with poststroke cognitive impairment. Small molecule inhibitor DDQ-treated hippocampal neuronal cells show improved neurite outgrowth and synaptic branching. Polyethylene glycol fusion repair of severed sciatic nerves accelerates recovery of nociceptive sensory perceptions in male and female rats of different strains. Reduced mesencephalic astrocyte-derived neurotrophic factor expression by mutant androgen receptor contributes to neurodegeneration in a model of spinal and bulbar muscular atrophy pathology. Enhanced autophagic clearance of amyloid-β via histone deacetylase 6-mediated V-ATPase assembly and lysosomal acidification protects against Alzheimer's disease in vitro and in vivo.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1