{"title":"不同材料和腔体设计对陶瓷局部覆盖层抗断裂性的影响。","authors":"Mahmoud Attia DDS, MSc, PhD, Nadia Fahmy DDS, MSc, PhD, Atef Shaker DDS, MSc, PhD, Tarek Salah DDS, MSc, PhD","doi":"10.1111/jerd.13286","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (<i>n</i> = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of different materials and cavity designs on fracture resistance of ceramic partial coverage\",\"authors\":\"Mahmoud Attia DDS, MSc, PhD, Nadia Fahmy DDS, MSc, PhD, Atef Shaker DDS, MSc, PhD, Tarek Salah DDS, MSc, PhD\",\"doi\":\"10.1111/jerd.13286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (<i>n</i> = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Clinical Significance</h3>\\n \\n <p>When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13286\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13286","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
The effect of different materials and cavity designs on fracture resistance of ceramic partial coverage
Background
Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces.
Methods
Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (n = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples.
Results
Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs.
Conclusions
Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did.
Clinical Significance
When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.
期刊介绍:
The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features.
The range of topics covered in the journal includes:
- Interdisciplinary esthetic concepts
- Implants
- Conservative adhesive restorations
- Tooth Whitening
- Prosthodontic materials and techniques
- Dental materials
- Orthodontic, periodontal and endodontic esthetics
- Esthetics related research
- Innovations in esthetics