{"title":"用于水净化的新型硅基吸附剂:以亚纳摩尔浓度去除短链和长链全氟烷基磺酸 (PFSA)","authors":"Stephan Lassen,&nbsp;Bernd Niemeyer","doi":"10.1007/s13201-024-02245-9","DOIUrl":null,"url":null,"abstract":"<div><p>Perfluoroalkyl acids (PFAAs) are widespread in the aquatic environment and also measurable in ground and drinking water. Because of the insufficient PFAA elimination in conventional water treatment processes, e. g. active carbon based methods, consumers in areas with contaminated water supplies are exposed to an elevated health hazard. For this purpose, the applicability of five differentially fluorinated silica-based adsorbents (HSU00107954-958) to remove the potentially human toxic perfluoroalkyl sulfonic acids(PFSAs) perfluorooctane sulfonic acid (PFOS), perfluorohexane sulfonic acid (PFHxS), and perfluorobutane sulfonic acid (PFBS) from water was investigated with regard to removal efficiencies (REs) and equilibrium loadings. During the adsorbent screening at nanomolar concentrations (20.0–33.4 nmol L<sup>−1</sup>) maximum REs of 46.9% for PFBS (HSU00107954), 79.4% for PFHxS (HSU00107954), and between 86.5 to 96.7% for PFOS (HSU00107956, and HSU00107954, respectively) have been achieved. Even at picomolar concentrations (&lt; 400 pmol L<sup>−1</sup>) HSU00107954 was still able to eliminate PFBS and PFHxS with an efficiency of 46.3–51.2% and 79.1–88.2%, respectively. Analyses of the equilibrium loadings of the functionalized adsorbents in the concentration range 40.1 pmol to 3.34 nmol L<sup>−1</sup> resulted in appropriate linearized Freundlich isotherms for all investigated PFSA. Compared to literature-based Freundlich adsorption coefficients (<i>K</i><sub>F</sub>) for granular activated carbon (GAC), the determined <i>K</i><sub>F</sub> values (nmol<sup>(1−<i>n</i>)</sup> L<sup><i>n</i></sup> m<sup>−2</sup>) of the most efficient adsorbents HSU00107956 and HSU00107954 for each PFSA were significantly 8–10 and 50–60 times higher, respectively. These proven increased adsorption capacities relative to activated carbon possibly indicate specific PFSA selectivities of the functionalized macroporous silica adsorbents.</p></div>","PeriodicalId":8374,"journal":{"name":"Applied Water Science","volume":"14 8","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s13201-024-02245-9.pdf","citationCount":"0","resultStr":"{\"title\":\"New silica-based adsorbents for water purification: Removal of short- and long-chain perfluoroalkyl sulfonic acids (PFSA) at sub-nanomolar concentrations\",\"authors\":\"Stephan Lassen,&nbsp;Bernd Niemeyer\",\"doi\":\"10.1007/s13201-024-02245-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Perfluoroalkyl acids (PFAAs) are widespread in the aquatic environment and also measurable in ground and drinking water. Because of the insufficient PFAA elimination in conventional water treatment processes, e. g. active carbon based methods, consumers in areas with contaminated water supplies are exposed to an elevated health hazard. For this purpose, the applicability of five differentially fluorinated silica-based adsorbents (HSU00107954-958) to remove the potentially human toxic perfluoroalkyl sulfonic acids(PFSAs) perfluorooctane sulfonic acid (PFOS), perfluorohexane sulfonic acid (PFHxS), and perfluorobutane sulfonic acid (PFBS) from water was investigated with regard to removal efficiencies (REs) and equilibrium loadings. During the adsorbent screening at nanomolar concentrations (20.0–33.4 nmol L<sup>−1</sup>) maximum REs of 46.9% for PFBS (HSU00107954), 79.4% for PFHxS (HSU00107954), and between 86.5 to 96.7% for PFOS (HSU00107956, and HSU00107954, respectively) have been achieved. Even at picomolar concentrations (&lt; 400 pmol L<sup>−1</sup>) HSU00107954 was still able to eliminate PFBS and PFHxS with an efficiency of 46.3–51.2% and 79.1–88.2%, respectively. Analyses of the equilibrium loadings of the functionalized adsorbents in the concentration range 40.1 pmol to 3.34 nmol L<sup>−1</sup> resulted in appropriate linearized Freundlich isotherms for all investigated PFSA. Compared to literature-based Freundlich adsorption coefficients (<i>K</i><sub>F</sub>) for granular activated carbon (GAC), the determined <i>K</i><sub>F</sub> values (nmol<sup>(1−<i>n</i>)</sup> L<sup><i>n</i></sup> m<sup>−2</sup>) of the most efficient adsorbents HSU00107956 and HSU00107954 for each PFSA were significantly 8–10 and 50–60 times higher, respectively. These proven increased adsorption capacities relative to activated carbon possibly indicate specific PFSA selectivities of the functionalized macroporous silica adsorbents.</p></div>\",\"PeriodicalId\":8374,\"journal\":{\"name\":\"Applied Water Science\",\"volume\":\"14 8\",\"pages\":\"\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s13201-024-02245-9.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Water Science\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13201-024-02245-9\",\"RegionNum\":3,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"WATER RESOURCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Water Science","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s13201-024-02245-9","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

摘要

全氟烷基酸 (PFAA) 广泛存在于水生环境中,在地下水和饮用水中也可以测量到。由于传统的水处理工艺(如活性碳法)无法充分消除全氟烷基酸,因此水源污染地区的消费者面临着更高的健康风险。为此,研究了五种不同氟硅吸附剂(HSU00107954-958)在去除水中可能对人体有毒的全氟烷基磺酸(PFSAs)全氟辛烷磺酸(PFOS)、全氟己烷磺酸(PFHxS)和全氟丁烷磺酸(PFBS)的去除率(REs)和平衡负荷方面的适用性。在纳摩尔浓度(20.0-33.4 nmol L-1)的吸附剂筛选过程中,PFBS(HSU00107954)的最大去除率为 46.9%,PFHxS(HSU00107954)为 79.4%,PFOS(HSU00107956 和 HSU00107954)为 86.5% 至 96.7%。即使在皮摩尔浓度(< 400 pmol L-1)下,HSU00107954 仍能消除 PFBS 和 PFHxS,效率分别为 46.3-51.2% 和 79.1-88.2%。在 40.1 pmol 至 3.34 nmol L-1 的浓度范围内,对功能化吸附剂的平衡负载进行分析,结果表明所有研究的 PFSA 都具有适当的线性化 Freundlich 等温线。与基于文献的粒状活性炭 (GAC) Freundlich 吸附系数 (KF) 相比,最高效吸附剂 HSU00107956 和 HSU00107954 对每种 PFSA 的 KF 值(nmol(1-n) Ln m-2)分别高出 8-10 倍和 50-60 倍。与活性炭相比,这些已证实的吸附能力的提高可能表明功能化大孔二氧化硅吸附剂具有特定的 PFSA 选择性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New silica-based adsorbents for water purification: Removal of short- and long-chain perfluoroalkyl sulfonic acids (PFSA) at sub-nanomolar concentrations

Perfluoroalkyl acids (PFAAs) are widespread in the aquatic environment and also measurable in ground and drinking water. Because of the insufficient PFAA elimination in conventional water treatment processes, e. g. active carbon based methods, consumers in areas with contaminated water supplies are exposed to an elevated health hazard. For this purpose, the applicability of five differentially fluorinated silica-based adsorbents (HSU00107954-958) to remove the potentially human toxic perfluoroalkyl sulfonic acids(PFSAs) perfluorooctane sulfonic acid (PFOS), perfluorohexane sulfonic acid (PFHxS), and perfluorobutane sulfonic acid (PFBS) from water was investigated with regard to removal efficiencies (REs) and equilibrium loadings. During the adsorbent screening at nanomolar concentrations (20.0–33.4 nmol L−1) maximum REs of 46.9% for PFBS (HSU00107954), 79.4% for PFHxS (HSU00107954), and between 86.5 to 96.7% for PFOS (HSU00107956, and HSU00107954, respectively) have been achieved. Even at picomolar concentrations (< 400 pmol L−1) HSU00107954 was still able to eliminate PFBS and PFHxS with an efficiency of 46.3–51.2% and 79.1–88.2%, respectively. Analyses of the equilibrium loadings of the functionalized adsorbents in the concentration range 40.1 pmol to 3.34 nmol L−1 resulted in appropriate linearized Freundlich isotherms for all investigated PFSA. Compared to literature-based Freundlich adsorption coefficients (KF) for granular activated carbon (GAC), the determined KF values (nmol(1−n) Ln m−2) of the most efficient adsorbents HSU00107956 and HSU00107954 for each PFSA were significantly 8–10 and 50–60 times higher, respectively. These proven increased adsorption capacities relative to activated carbon possibly indicate specific PFSA selectivities of the functionalized macroporous silica adsorbents.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Water Science
Applied Water Science WATER RESOURCES-
CiteScore
9.90
自引率
3.60%
发文量
268
审稿时长
13 weeks
期刊介绍:
期刊最新文献
Simulation of wheat water footprint using AquaCrop model under the climate change, case study in Qazvin plain An innovative approach for quality assessment and its contamination on surface water for drinking purpose in Mahanadi River Basin, Odisha of India, with the integration of BA-WQI, AHP-TOPSIS, FL-DWQI, MOORA, and RF methodology Identifying homogeneous hydrological zones for flood prediction using multivariable statistical methods and machine learning Controlling stormwater at the source: dawn of a new era in integrated water resources management Adoption challenges of environmental monitoring practices: case study of temperature data loggers in selected Australian vegetable supply chains
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1