{"title":"基于 CART 的大容量电力系统跨区振荡阻尼控制器(由 WAMS 数据组成","authors":"Soheil Ranjbar","doi":"10.1016/j.isatra.2024.07.028","DOIUrl":null,"url":null,"abstract":"<div><p>The paper proposes a WADC approach using CART technique to dampen inter-area oscillations (IAOs) in bulk power systems. In this case, PMU data are filtered to estimate inter-area dynamics in which using pade approximation, a pole-zero IAO compensation block is designed. An online random decrement technique is also developed to identify the coherent groups and damping ratios to activate the WADC for oscillation damping. An offline process is provided to identify 200 critical IAO contingencies and tunes WADC gains using PSO for training CARTs via a set of 200 input inter-area signals and assigning output controlling gains pre-trained data and evaluating the CART estimations through online operation. The WADC approach is validated for oscillation damping on a 39-bus system and a realistic 561-generator Iranian grid. Simulations show 98 % accuracy in achieving sufficient damping ratios (>0.6) across various operating conditions.</p></div>","PeriodicalId":14660,"journal":{"name":"ISA transactions","volume":"153 ","pages":"Pages 350-363"},"PeriodicalIF":6.3000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CART-based wide-area damping controller for inter-area oscillations in bulk power system consisting of WAMS data\",\"authors\":\"Soheil Ranjbar\",\"doi\":\"10.1016/j.isatra.2024.07.028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The paper proposes a WADC approach using CART technique to dampen inter-area oscillations (IAOs) in bulk power systems. In this case, PMU data are filtered to estimate inter-area dynamics in which using pade approximation, a pole-zero IAO compensation block is designed. An online random decrement technique is also developed to identify the coherent groups and damping ratios to activate the WADC for oscillation damping. An offline process is provided to identify 200 critical IAO contingencies and tunes WADC gains using PSO for training CARTs via a set of 200 input inter-area signals and assigning output controlling gains pre-trained data and evaluating the CART estimations through online operation. The WADC approach is validated for oscillation damping on a 39-bus system and a realistic 561-generator Iranian grid. Simulations show 98 % accuracy in achieving sufficient damping ratios (>0.6) across various operating conditions.</p></div>\",\"PeriodicalId\":14660,\"journal\":{\"name\":\"ISA transactions\",\"volume\":\"153 \",\"pages\":\"Pages 350-363\"},\"PeriodicalIF\":6.3000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISA transactions\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0019057824003628\",\"RegionNum\":2,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUTOMATION & CONTROL SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISA transactions","FirstCategoryId":"94","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019057824003628","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
CART-based wide-area damping controller for inter-area oscillations in bulk power system consisting of WAMS data
The paper proposes a WADC approach using CART technique to dampen inter-area oscillations (IAOs) in bulk power systems. In this case, PMU data are filtered to estimate inter-area dynamics in which using pade approximation, a pole-zero IAO compensation block is designed. An online random decrement technique is also developed to identify the coherent groups and damping ratios to activate the WADC for oscillation damping. An offline process is provided to identify 200 critical IAO contingencies and tunes WADC gains using PSO for training CARTs via a set of 200 input inter-area signals and assigning output controlling gains pre-trained data and evaluating the CART estimations through online operation. The WADC approach is validated for oscillation damping on a 39-bus system and a realistic 561-generator Iranian grid. Simulations show 98 % accuracy in achieving sufficient damping ratios (>0.6) across various operating conditions.
期刊介绍:
ISA Transactions serves as a platform for showcasing advancements in measurement and automation, catering to both industrial practitioners and applied researchers. It covers a wide array of topics within measurement, including sensors, signal processing, data analysis, and fault detection, supported by techniques such as artificial intelligence and communication systems. Automation topics encompass control strategies, modelling, system reliability, and maintenance, alongside optimization and human-machine interaction. The journal targets research and development professionals in control systems, process instrumentation, and automation from academia and industry.