Claus E. Andersen, M. F. Klavsen, Christina Ankjærgaard
{"title":"在磁共振成像仪中使用 Al2O3:C 和塑料闪烁体进行小场剂量测定","authors":"Claus E. Andersen, M. F. Klavsen, Christina Ankjærgaard","doi":"10.1088/1742-6596/2799/1/012017","DOIUrl":null,"url":null,"abstract":"\n Fiber coupled luminescence detectors based on organic plastic scintillators or inorganic materials such as Al2O3:C are suitable for dosimetry in strong magnetic fields as found in MR-linacs. The main finding of this work was that field-output factor measurements at the maximum dose point are less variable than if measured at the central beam axis (CAX). In contrast to plastic scintillators, Al2O3:C was found to have a yield of radioluminescence per dose that (within uncertainty) is independent of the magnetic field strength.","PeriodicalId":506941,"journal":{"name":"Journal of Physics: Conference Series","volume":"13 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the use of Al2O3:C and plastic scintillators for small-field dosimetry in MR-linacs\",\"authors\":\"Claus E. Andersen, M. F. Klavsen, Christina Ankjærgaard\",\"doi\":\"10.1088/1742-6596/2799/1/012017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Fiber coupled luminescence detectors based on organic plastic scintillators or inorganic materials such as Al2O3:C are suitable for dosimetry in strong magnetic fields as found in MR-linacs. The main finding of this work was that field-output factor measurements at the maximum dose point are less variable than if measured at the central beam axis (CAX). In contrast to plastic scintillators, Al2O3:C was found to have a yield of radioluminescence per dose that (within uncertainty) is independent of the magnetic field strength.\",\"PeriodicalId\":506941,\"journal\":{\"name\":\"Journal of Physics: Conference Series\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physics: Conference Series\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1742-6596/2799/1/012017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics: Conference Series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1742-6596/2799/1/012017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On the use of Al2O3:C and plastic scintillators for small-field dosimetry in MR-linacs
Fiber coupled luminescence detectors based on organic plastic scintillators or inorganic materials such as Al2O3:C are suitable for dosimetry in strong magnetic fields as found in MR-linacs. The main finding of this work was that field-output factor measurements at the maximum dose point are less variable than if measured at the central beam axis (CAX). In contrast to plastic scintillators, Al2O3:C was found to have a yield of radioluminescence per dose that (within uncertainty) is independent of the magnetic field strength.