Afnan O. Al-Zain BDS, MSD, PhD, Eman H. Ismail DDS, Ms, PhD, Abdulrahman A. Balhaddad BDS, MSD, PhD, Osamah Toras, Yousif Alharthy, Rafa Alsultan BDS, Abeer Alrossais BDS, Richard B. Price BDS, DDS, MS, FDS, RCS, FRCD(C), PhD
{"title":"评估牙科光固化设备说明书中提供的信息。","authors":"Afnan O. Al-Zain BDS, MSD, PhD, Eman H. Ismail DDS, Ms, PhD, Abdulrahman A. Balhaddad BDS, MSD, PhD, Osamah Toras, Yousif Alharthy, Rafa Alsultan BDS, Abeer Alrossais BDS, Richard B. Price BDS, DDS, MS, FDS, RCS, FRCD(C), PhD","doi":"10.1111/jerd.13280","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>This study evaluated the completeness and accuracy of information in LCU instruction manuals from 40 manufacturers.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Instruction manuals from 40 LCUs (20 from leading manufacturers and 20 budget units) were reviewed. Twenty-eight parameters across five categories were assessed using a binary scale (0=incorrect/missing, 1=correct). The categories and their respective evaluation scores were: LCU characteristics (43%), instructions for use (7%), safety precautions (14%), maintenance recommendations (29%), and regulatory certification (7%). These scores were combined to produce a final score.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Scores from leading manufacturers ranged between 46-86%, while the budget category ranged from 18-68%. All manuals provided information about the wavelength/spectrum of the LCU. Only Valo X and Valo Cordless reported power values and used the term “irradiance” instead of “intensity.” Details such as LED type and active tip emission area were often missing. Instructions on how to use the LCU to photo-cure resins were frequently limited. Although most manuals addressed safety precautions, several lacked details on heat issues and general health precautions. All manuals included maintenance instructions, though information on replacement parts was often missing. Among the LCUs, 85% stated they were CE certified, 32% held both FDA and CE certification, and 63% claimed compliance with ISO and/or IEC standards.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>There were notable differences in the completeness and accuracy of the instruction manuals. Manuals from major manufacturers generally provided more comprehensive information than their budget counterparts.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>Instruction manuals should contain accurate information to help clinicians deliver the highest standard of care. The lack of important information about the LCUs in the manuals is concerning.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the information provided in the instruction manuals of dental light-curing units\",\"authors\":\"Afnan O. Al-Zain BDS, MSD, PhD, Eman H. Ismail DDS, Ms, PhD, Abdulrahman A. Balhaddad BDS, MSD, PhD, Osamah Toras, Yousif Alharthy, Rafa Alsultan BDS, Abeer Alrossais BDS, Richard B. Price BDS, DDS, MS, FDS, RCS, FRCD(C), PhD\",\"doi\":\"10.1111/jerd.13280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>This study evaluated the completeness and accuracy of information in LCU instruction manuals from 40 manufacturers.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>Instruction manuals from 40 LCUs (20 from leading manufacturers and 20 budget units) were reviewed. Twenty-eight parameters across five categories were assessed using a binary scale (0=incorrect/missing, 1=correct). The categories and their respective evaluation scores were: LCU characteristics (43%), instructions for use (7%), safety precautions (14%), maintenance recommendations (29%), and regulatory certification (7%). These scores were combined to produce a final score.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Scores from leading manufacturers ranged between 46-86%, while the budget category ranged from 18-68%. All manuals provided information about the wavelength/spectrum of the LCU. Only Valo X and Valo Cordless reported power values and used the term “irradiance” instead of “intensity.” Details such as LED type and active tip emission area were often missing. Instructions on how to use the LCU to photo-cure resins were frequently limited. Although most manuals addressed safety precautions, several lacked details on heat issues and general health precautions. All manuals included maintenance instructions, though information on replacement parts was often missing. Among the LCUs, 85% stated they were CE certified, 32% held both FDA and CE certification, and 63% claimed compliance with ISO and/or IEC standards.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>There were notable differences in the completeness and accuracy of the instruction manuals. Manuals from major manufacturers generally provided more comprehensive information than their budget counterparts.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Clinical Significance</h3>\\n \\n <p>Instruction manuals should contain accurate information to help clinicians deliver the highest standard of care. The lack of important information about the LCUs in the manuals is concerning.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13280\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13280","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
研究目的本研究评估了 40 家制造商的 LCU 使用手册中信息的完整性和准确性:对 40 个 LCU(20 个来自领先制造商,20 个来自预算单位)的使用手册进行了审查。采用二元量表(0=不正确/遗漏,1=正确)对五个类别的 28 个参数进行了评估。这些类别及其各自的评估分数分别是LCU 特性 (43%)、使用说明 (7%)、安全注意事项 (14%)、维护建议 (29%) 和法规认证 (7%)。综合这些得分得出最终得分:结果:主要制造商的得分率在 46-86% 之间,而经济型制造商的得分率在 18-68% 之间。所有手册都提供了有关 LCU 波长/光谱的信息。只有 Valo X 和 Valo Cordless 报告了功率值,并使用了 "辐照度 "一词而不是 "强度"。LED 类型和有效尖端发射区域等详细信息往往缺失。关于如何使用 LCU 光固化树脂的说明往往很有限。虽然大多数手册都提到了安全预防措施,但有几份手册缺少有关热量问题和一般健康预防措施的详细信息。所有手册都包括维护说明,但往往缺少有关更换部件的信息。在 LCU 中,85% 表示已通过 CE 认证,32% 同时拥有 FDA 和 CE 认证,63% 声称符合 ISO 和/或 IEC 标准:说明手册的完整性和准确性存在明显差异。结论:说明书的完整性和准确性存在明显差异,大型制造商的说明书通常比预算有限的同类产品提供更全面的信息:临床意义:说明书应包含准确的信息,以帮助临床医生提供最高标准的医疗服务。手册中缺乏有关 LCU 的重要信息令人担忧。
Evaluation of the information provided in the instruction manuals of dental light-curing units
Objective
This study evaluated the completeness and accuracy of information in LCU instruction manuals from 40 manufacturers.
Materials and Methods
Instruction manuals from 40 LCUs (20 from leading manufacturers and 20 budget units) were reviewed. Twenty-eight parameters across five categories were assessed using a binary scale (0=incorrect/missing, 1=correct). The categories and their respective evaluation scores were: LCU characteristics (43%), instructions for use (7%), safety precautions (14%), maintenance recommendations (29%), and regulatory certification (7%). These scores were combined to produce a final score.
Results
Scores from leading manufacturers ranged between 46-86%, while the budget category ranged from 18-68%. All manuals provided information about the wavelength/spectrum of the LCU. Only Valo X and Valo Cordless reported power values and used the term “irradiance” instead of “intensity.” Details such as LED type and active tip emission area were often missing. Instructions on how to use the LCU to photo-cure resins were frequently limited. Although most manuals addressed safety precautions, several lacked details on heat issues and general health precautions. All manuals included maintenance instructions, though information on replacement parts was often missing. Among the LCUs, 85% stated they were CE certified, 32% held both FDA and CE certification, and 63% claimed compliance with ISO and/or IEC standards.
Conclusions
There were notable differences in the completeness and accuracy of the instruction manuals. Manuals from major manufacturers generally provided more comprehensive information than their budget counterparts.
Clinical Significance
Instruction manuals should contain accurate information to help clinicians deliver the highest standard of care. The lack of important information about the LCUs in the manuals is concerning.
期刊介绍:
The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features.
The range of topics covered in the journal includes:
- Interdisciplinary esthetic concepts
- Implants
- Conservative adhesive restorations
- Tooth Whitening
- Prosthodontic materials and techniques
- Dental materials
- Orthodontic, periodontal and endodontic esthetics
- Esthetics related research
- Innovations in esthetics