在 CEUS 引导下进行粗针活检后,组织病理学检查和 Xpert (MTB/RIF) 检测对宫颈淋巴结结核诊断的价值:对 612 例病例的回顾性分析。

IF 3.7 3区 医学 Q2 INFECTIOUS DISEASES European Journal of Clinical Microbiology & Infectious Diseases Pub Date : 2024-10-01 Epub Date: 2024-08-01 DOI:10.1007/s10096-024-04913-9
Wenzhi Zhang, Jianping Xu, Lin Zhang, Tu Ni
{"title":"在 CEUS 引导下进行粗针活检后,组织病理学检查和 Xpert (MTB/RIF) 检测对宫颈淋巴结结核诊断的价值:对 612 例病例的回顾性分析。","authors":"Wenzhi Zhang, Jianping Xu, Lin Zhang, Tu Ni","doi":"10.1007/s10096-024-04913-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the value of histopathological examination (HPE) and Xpert Mycobacterium tuberculosis bacilli/rifampicin (MTB/RIF) assay in diagnosis of cervical lymph node tuberculosis (LN TB) after coarse needle biopsy (CNB).</p><p><strong>Methods: </strong>We retrospectively analyzed 612 samples obtained from October 2017 to August 2023 from patients suspected cervical LN TB with surgically pathological, microbial culture confirmed, and clinically confirmed cervical lymph node enlargement who received ultrasound-guided CNB assisted by contrast-enhanced ultrasound (CEUS) at our hospital. All specimens were assessed by HPE and the Xpert (MTB/RIF) assay. We analyzed the results to determine the diagnostic value of HPE and Xpert (MTB/RIF) assay in samples taken after CEUS-assisted CNB of LN TB, and to evaluate the safety of CNB.</p><p><strong>Results: </strong>Based on the comprehensive reference standard established in this study, 532 of 612 patients were diagnosed with cervical LN TB, of which 476 were CNB positive cases, the positive rate of diagnosis was 89.5%。The sensitivity, specificity, positive predictive value, negative and predictive value of HPE were 80.4%, 91.2%, 98.4%, 41.2% respectively, while those of the Xpert MTB/RIF assay were 75.7%, 98.7%, 99.7%, 38.0% respectively. No postoperative complications were noted, and the Clavien-Dindo grade was 2.</p><p><strong>Conclusion: </strong>CEUS-assisted CNB has high diagnostic value and is safe for cervical LN TB. The sensitivity of HPE is slightly higher than that of Xpert (MTB/RIF) assay, and the specificity of Xpert (MTB/RIF) assay is higher than that of HPE, so Xpert (MTB/RIF) assay can correct the cervical lymph node tuberculosis with negative HPE.</p>","PeriodicalId":11782,"journal":{"name":"European Journal of Clinical Microbiology & Infectious Diseases","volume":" ","pages":"1951-1957"},"PeriodicalIF":3.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11405491/pdf/","citationCount":"0","resultStr":"{\"title\":\"The value of histopathologic examination and Xpert (MTB/RIF) assay in diagnosis of cervical lymph node tuberculosis after coarse needle biopsy guided by CEUS: a retrospective analysis of 612 cases.\",\"authors\":\"Wenzhi Zhang, Jianping Xu, Lin Zhang, Tu Ni\",\"doi\":\"10.1007/s10096-024-04913-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate the value of histopathological examination (HPE) and Xpert Mycobacterium tuberculosis bacilli/rifampicin (MTB/RIF) assay in diagnosis of cervical lymph node tuberculosis (LN TB) after coarse needle biopsy (CNB).</p><p><strong>Methods: </strong>We retrospectively analyzed 612 samples obtained from October 2017 to August 2023 from patients suspected cervical LN TB with surgically pathological, microbial culture confirmed, and clinically confirmed cervical lymph node enlargement who received ultrasound-guided CNB assisted by contrast-enhanced ultrasound (CEUS) at our hospital. All specimens were assessed by HPE and the Xpert (MTB/RIF) assay. We analyzed the results to determine the diagnostic value of HPE and Xpert (MTB/RIF) assay in samples taken after CEUS-assisted CNB of LN TB, and to evaluate the safety of CNB.</p><p><strong>Results: </strong>Based on the comprehensive reference standard established in this study, 532 of 612 patients were diagnosed with cervical LN TB, of which 476 were CNB positive cases, the positive rate of diagnosis was 89.5%。The sensitivity, specificity, positive predictive value, negative and predictive value of HPE were 80.4%, 91.2%, 98.4%, 41.2% respectively, while those of the Xpert MTB/RIF assay were 75.7%, 98.7%, 99.7%, 38.0% respectively. No postoperative complications were noted, and the Clavien-Dindo grade was 2.</p><p><strong>Conclusion: </strong>CEUS-assisted CNB has high diagnostic value and is safe for cervical LN TB. The sensitivity of HPE is slightly higher than that of Xpert (MTB/RIF) assay, and the specificity of Xpert (MTB/RIF) assay is higher than that of HPE, so Xpert (MTB/RIF) assay can correct the cervical lymph node tuberculosis with negative HPE.</p>\",\"PeriodicalId\":11782,\"journal\":{\"name\":\"European Journal of Clinical Microbiology & Infectious Diseases\",\"volume\":\" \",\"pages\":\"1951-1957\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11405491/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Clinical Microbiology & Infectious Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10096-024-04913-9\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Clinical Microbiology & Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10096-024-04913-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨组织病理学检查(HPE)和Xpert结核分枝杆菌/利福平(MTB/RIF)检测在粗针活检(CNB)后宫颈淋巴结结核(LN TB)诊断中的价值:我们回顾性分析了2017年10月至2023年8月期间获得的612份样本,这些样本来自我院接受超声引导CNB辅助造影剂增强超声(CEUS)检查的疑似宫颈淋巴结结核患者,这些患者均经手术病理、微生物培养证实和临床证实为宫颈淋巴结肿大。所有标本均通过 HPE 和 Xpert(MTB/RIF)检测进行评估。我们对结果进行了分析,以确定 HPE 和 Xpert(MTB/RIF)检测在 CEUS 辅助下行 LN 结核病 CNB 后样本中的诊断价值,并评估 CNB 的安全性:根据该研究建立的综合参考标准,612 例患者中有 532 例确诊为宫颈 LN TB,其中 476 例为 CNB 阳性病例,确诊阳性率为 89.5%。HPE 的灵敏度、特异性、阳性预测值、阴性预测值和预测值分别为 80.4%、91.2%、98.4%、41.2%,而 Xpert MTB/RIF 检测的灵敏度、特异性、阳性预测值、阴性预测值和预测值分别为 75.7%、98.7%、99.7%、38.0%。术后未发现并发症,Clavien-Dindo分级为2.Conclusion:结论:CEUS辅助CNB对宫颈LN结核的诊断价值高且安全。HPE 的灵敏度略高于 Xpert(MTB/RIF)测定,而 Xpert(MTB/RIF)测定的特异性高于 HPE,因此 Xpert(MTB/RIF)测定可以纠正 HPE 阴性的宫颈淋巴结结核。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The value of histopathologic examination and Xpert (MTB/RIF) assay in diagnosis of cervical lymph node tuberculosis after coarse needle biopsy guided by CEUS: a retrospective analysis of 612 cases.

Objective: To investigate the value of histopathological examination (HPE) and Xpert Mycobacterium tuberculosis bacilli/rifampicin (MTB/RIF) assay in diagnosis of cervical lymph node tuberculosis (LN TB) after coarse needle biopsy (CNB).

Methods: We retrospectively analyzed 612 samples obtained from October 2017 to August 2023 from patients suspected cervical LN TB with surgically pathological, microbial culture confirmed, and clinically confirmed cervical lymph node enlargement who received ultrasound-guided CNB assisted by contrast-enhanced ultrasound (CEUS) at our hospital. All specimens were assessed by HPE and the Xpert (MTB/RIF) assay. We analyzed the results to determine the diagnostic value of HPE and Xpert (MTB/RIF) assay in samples taken after CEUS-assisted CNB of LN TB, and to evaluate the safety of CNB.

Results: Based on the comprehensive reference standard established in this study, 532 of 612 patients were diagnosed with cervical LN TB, of which 476 were CNB positive cases, the positive rate of diagnosis was 89.5%。The sensitivity, specificity, positive predictive value, negative and predictive value of HPE were 80.4%, 91.2%, 98.4%, 41.2% respectively, while those of the Xpert MTB/RIF assay were 75.7%, 98.7%, 99.7%, 38.0% respectively. No postoperative complications were noted, and the Clavien-Dindo grade was 2.

Conclusion: CEUS-assisted CNB has high diagnostic value and is safe for cervical LN TB. The sensitivity of HPE is slightly higher than that of Xpert (MTB/RIF) assay, and the specificity of Xpert (MTB/RIF) assay is higher than that of HPE, so Xpert (MTB/RIF) assay can correct the cervical lymph node tuberculosis with negative HPE.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.40
自引率
2.20%
发文量
138
审稿时长
1 months
期刊介绍: EJCMID is an interdisciplinary journal devoted to the publication of communications on infectious diseases of bacterial, viral and parasitic origin.
期刊最新文献
Comparison of performances of laboratory methods in diagnosing pulmonary cryptococcosis in 1508 patients having lung biopsy tissues collected: a 6-year retrospective study. Treatment outcomes and their predictors in children hospitalized with varicella complicated by bacterial superinfections after pandemic of COVID-19 - a retrospective multicenter analysis of real-life data in Poland. Vaginal microbiota stability over 18 months in young student women in France. Carbapenem resistant Campylobacter jejuni bacteremia in a Bruton's X-linked agammaglobulinemia patient. Clinical experience with ceftazidime/avibactam for the treatment of extensively drug-resistant or pandrug-resistant Klebsiella pneumoniae in neonates and children.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1