{"title":"金属对金属髋关节置换术:它安全可靠吗?HRA的过去、现在和未来简介。","authors":"Feng Xie, Shuya Sheng, Jeya Palan, Hemant G Pandit","doi":"10.1530/EOR-23-0099","DOIUrl":null,"url":null,"abstract":"<p><p>This paper discusses the existing literature in the field of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), the background (why was it developed), the past (what was the evidence leading to its rise and fall in clinical use), the present situation (why a potential resurgence), and the future directions for potential improvements. All literature relevant to MoM HRA was reviewed and summarized to provide a comprehensive summary. Furthermore, a detailed literature search was performed on PubMeD, MEDLINE, and Google Scholar to identify all clinical studies reporting a minimum 10 years of outcomes for modern MoM HRA devices from February 2018 to February 2023. In addition, joint registry data over the same time period, available in the public domain, was examined to extract related information on MoM HRA. Metal ions are present in almost all types of hip replacement; on the whole, however, the risk of revision for resurfacing due to metal-related pathologies is very low, but higher than in other types of bearings. There are studies that show that some brands of MoM resurfacing prostheses have achieved excellent clinical outcomes in long-term follow-up studies and are still in use although less commonly than in early 2000s. Use of alternative bearing surfaces has demonstrated excellent results in the short-term and a very critical long-term follow-up of these cases still will help establish their place in the hip arthroplasty world. HRA deserves a permanent place in the armamentarium of orthopedic surgeons and in the hand of experienced surgeons.</p>","PeriodicalId":48598,"journal":{"name":"Efort Open Reviews","volume":"9 8","pages":"751-761"},"PeriodicalIF":4.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11370715/pdf/","citationCount":"0","resultStr":"{\"title\":\"Metal-on-metal hip resurfacing arthroplasty: is it safe and reliable? A synopsis of the past, the present, and the future of HRA.\",\"authors\":\"Feng Xie, Shuya Sheng, Jeya Palan, Hemant G Pandit\",\"doi\":\"10.1530/EOR-23-0099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper discusses the existing literature in the field of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), the background (why was it developed), the past (what was the evidence leading to its rise and fall in clinical use), the present situation (why a potential resurgence), and the future directions for potential improvements. All literature relevant to MoM HRA was reviewed and summarized to provide a comprehensive summary. Furthermore, a detailed literature search was performed on PubMeD, MEDLINE, and Google Scholar to identify all clinical studies reporting a minimum 10 years of outcomes for modern MoM HRA devices from February 2018 to February 2023. In addition, joint registry data over the same time period, available in the public domain, was examined to extract related information on MoM HRA. Metal ions are present in almost all types of hip replacement; on the whole, however, the risk of revision for resurfacing due to metal-related pathologies is very low, but higher than in other types of bearings. There are studies that show that some brands of MoM resurfacing prostheses have achieved excellent clinical outcomes in long-term follow-up studies and are still in use although less commonly than in early 2000s. Use of alternative bearing surfaces has demonstrated excellent results in the short-term and a very critical long-term follow-up of these cases still will help establish their place in the hip arthroplasty world. HRA deserves a permanent place in the armamentarium of orthopedic surgeons and in the hand of experienced surgeons.</p>\",\"PeriodicalId\":48598,\"journal\":{\"name\":\"Efort Open Reviews\",\"volume\":\"9 8\",\"pages\":\"751-761\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11370715/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Efort Open Reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1530/EOR-23-0099\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Efort Open Reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1530/EOR-23-0099","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
本文讨论了金属(MoM)髋关节置换术(HRA)领域的现有文献、背景(为什么要开发这种手术)、过去(导致其在临床应用中兴衰的证据是什么)、现状(为什么可能重新兴起)以及未来可能改进的方向。对所有与 MoM HRA 相关的文献进行了回顾和总结,以提供一份全面的摘要。此外,还在 PubMeD、MEDLINE 和 Google Scholar 上进行了详细的文献检索,以确定所有报告现代 MoM HRA 设备从 2018 年 2 月到 2023 年 2 月至少 10 年疗效的临床研究。此外,还研究了公共领域中可获得的同期联合登记数据,以提取有关 MoM HRA 的相关信息。金属离子几乎存在于所有类型的髋关节置换术中;但总体而言,因金属相关病变导致的再置换术翻修风险非常低,但高于其他类型的轴承。有研究表明,在长期随访研究中,某些品牌的MoM重置假体取得了很好的临床疗效,目前仍在使用,但使用率较2000年代初有所下降。使用替代轴承表面在短期内取得了极佳的效果,对这些病例进行非常关键的长期随访仍将有助于确立它们在髋关节置换术领域的地位。髋关节置换术在矫形外科医生和经验丰富的外科医生的手中理应占有一席之地。
Metal-on-metal hip resurfacing arthroplasty: is it safe and reliable? A synopsis of the past, the present, and the future of HRA.
This paper discusses the existing literature in the field of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), the background (why was it developed), the past (what was the evidence leading to its rise and fall in clinical use), the present situation (why a potential resurgence), and the future directions for potential improvements. All literature relevant to MoM HRA was reviewed and summarized to provide a comprehensive summary. Furthermore, a detailed literature search was performed on PubMeD, MEDLINE, and Google Scholar to identify all clinical studies reporting a minimum 10 years of outcomes for modern MoM HRA devices from February 2018 to February 2023. In addition, joint registry data over the same time period, available in the public domain, was examined to extract related information on MoM HRA. Metal ions are present in almost all types of hip replacement; on the whole, however, the risk of revision for resurfacing due to metal-related pathologies is very low, but higher than in other types of bearings. There are studies that show that some brands of MoM resurfacing prostheses have achieved excellent clinical outcomes in long-term follow-up studies and are still in use although less commonly than in early 2000s. Use of alternative bearing surfaces has demonstrated excellent results in the short-term and a very critical long-term follow-up of these cases still will help establish their place in the hip arthroplasty world. HRA deserves a permanent place in the armamentarium of orthopedic surgeons and in the hand of experienced surgeons.
期刊介绍:
EFORT Open Reviews publishes high-quality instructional review articles across the whole field of orthopaedics and traumatology. Commissioned, peer-reviewed articles from international experts summarize current knowledge and practice in orthopaedics, with the aim of providing systematic coverage of the field. All articles undergo rigorous scientific editing to ensure the highest standards of accuracy and clarity.