Ayooluwa S Ayoola, Michael A Charters, Hamza M Raja, Luke Weseman, Peter L Lewis, Yi Peng, Wayne Trevor North
{"title":"初级 NexGen 膝关节置换术的存活率:无骨水泥小梁金属与其他胫骨组件设计的比较。","authors":"Ayooluwa S Ayoola, Michael A Charters, Hamza M Raja, Luke Weseman, Peter L Lewis, Yi Peng, Wayne Trevor North","doi":"10.1055/a-2376-6889","DOIUrl":null,"url":null,"abstract":"<p><p>The impact of cementless trabecular metal (TM) implants on implant survivorship are not well delineated. This study compares primary total knee arthroplasty (TKA) revision rates of cemented knee replacements with two cementless knee replacement designs-cementless TM and a non-TM cementless design. Data from a national registry queried TKA procedures performed for osteoarthritis from 1999 to 2020. The risk of revision of Zimmer NexGen TKA using cementless TM, cementless non-TM, and cemented non-TM were compared. Analyses included Kaplan-Meier estimates of survivorship and Cox hazard ratios (HR), stratified by age and gender. Cementless TM components had higher risks of revision compared with cementless non-TM implants (HR = 1.49; <i>p</i> ≤ 0.001). Cementless TM implants showed higher risks of revision compared with cemented non-TM prostheses for the first 2 years (HR = 1.75, <i>p</i> < 0.001). Non-TM prostheses posed equal risk of revision for cementless and cemented fixations (HR = 0.95, <i>p</i> = 0.522). Patients aged 55 to 64 years and 65 to 74 years had a higher risk of revision for cementless TM compared with cementless non-TM (HR = 1.40, <i>p</i> = 0.033 and HR = 1.79, <i>p</i> < 0.001, respectively) and cemented non-TM implants (HR = 1.51, <i>p</i> < 0.001 and HR = 1.54, <i>p</i> < 0.001, respectively). The study shows there is an increased risk of revision with TM cementless implants for patients aged 55 to 74 years. These results do not support the use of TM tibial implants for patients of this age group for primary TKA.</p>","PeriodicalId":48798,"journal":{"name":"Journal of Knee Surgery","volume":" ","pages":"949-958"},"PeriodicalIF":1.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Survivorship of Primary NexGen Knee Replacement: Comparing Cementless Trabecular Metal to Other Designs of Tibial Component.\",\"authors\":\"Ayooluwa S Ayoola, Michael A Charters, Hamza M Raja, Luke Weseman, Peter L Lewis, Yi Peng, Wayne Trevor North\",\"doi\":\"10.1055/a-2376-6889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The impact of cementless trabecular metal (TM) implants on implant survivorship are not well delineated. This study compares primary total knee arthroplasty (TKA) revision rates of cemented knee replacements with two cementless knee replacement designs-cementless TM and a non-TM cementless design. Data from a national registry queried TKA procedures performed for osteoarthritis from 1999 to 2020. The risk of revision of Zimmer NexGen TKA using cementless TM, cementless non-TM, and cemented non-TM were compared. Analyses included Kaplan-Meier estimates of survivorship and Cox hazard ratios (HR), stratified by age and gender. Cementless TM components had higher risks of revision compared with cementless non-TM implants (HR = 1.49; <i>p</i> ≤ 0.001). Cementless TM implants showed higher risks of revision compared with cemented non-TM prostheses for the first 2 years (HR = 1.75, <i>p</i> < 0.001). Non-TM prostheses posed equal risk of revision for cementless and cemented fixations (HR = 0.95, <i>p</i> = 0.522). Patients aged 55 to 64 years and 65 to 74 years had a higher risk of revision for cementless TM compared with cementless non-TM (HR = 1.40, <i>p</i> = 0.033 and HR = 1.79, <i>p</i> < 0.001, respectively) and cemented non-TM implants (HR = 1.51, <i>p</i> < 0.001 and HR = 1.54, <i>p</i> < 0.001, respectively). The study shows there is an increased risk of revision with TM cementless implants for patients aged 55 to 74 years. These results do not support the use of TM tibial implants for patients of this age group for primary TKA.</p>\",\"PeriodicalId\":48798,\"journal\":{\"name\":\"Journal of Knee Surgery\",\"volume\":\" \",\"pages\":\"949-958\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Knee Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2376-6889\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Knee Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2376-6889","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Survivorship of Primary NexGen Knee Replacement: Comparing Cementless Trabecular Metal to Other Designs of Tibial Component.
The impact of cementless trabecular metal (TM) implants on implant survivorship are not well delineated. This study compares primary total knee arthroplasty (TKA) revision rates of cemented knee replacements with two cementless knee replacement designs-cementless TM and a non-TM cementless design. Data from a national registry queried TKA procedures performed for osteoarthritis from 1999 to 2020. The risk of revision of Zimmer NexGen TKA using cementless TM, cementless non-TM, and cemented non-TM were compared. Analyses included Kaplan-Meier estimates of survivorship and Cox hazard ratios (HR), stratified by age and gender. Cementless TM components had higher risks of revision compared with cementless non-TM implants (HR = 1.49; p ≤ 0.001). Cementless TM implants showed higher risks of revision compared with cemented non-TM prostheses for the first 2 years (HR = 1.75, p < 0.001). Non-TM prostheses posed equal risk of revision for cementless and cemented fixations (HR = 0.95, p = 0.522). Patients aged 55 to 64 years and 65 to 74 years had a higher risk of revision for cementless TM compared with cementless non-TM (HR = 1.40, p = 0.033 and HR = 1.79, p < 0.001, respectively) and cemented non-TM implants (HR = 1.51, p < 0.001 and HR = 1.54, p < 0.001, respectively). The study shows there is an increased risk of revision with TM cementless implants for patients aged 55 to 74 years. These results do not support the use of TM tibial implants for patients of this age group for primary TKA.
期刊介绍:
The Journal of Knee Surgery covers a range of issues relating to the orthopaedic techniques of arthroscopy, arthroplasty, and reconstructive surgery of the knee joint. In addition to original peer-review articles, this periodical provides details on emerging surgical techniques, as well as reviews and special focus sections. Topics of interest include cruciate ligament repair and reconstruction, bone grafting, cartilage regeneration, and magnetic resonance imaging.